Command
Description
Enter
Starts the search process.
2.2.2
Sort / Filter
When you use the Sort / Filter function, the sorting can be alphabetical (from A - Z or from Z
to A) for all devices or all areas, for example, or the function can be narrowed by selecting
faulted, bypassed, unbypassed, enabled, or disabled devices.
All areas can be sorted, or the sorting function can be narrowed by selecting armed, disarmed,
ready to arm, not ready to arm, ready to disarm, or not ready to disarm areas. More
information is provided in the sections that cover the commands that allow sorting and
filtering.
2.3
Arm - Using the Control Center
Notice!
A system installed with Smartkey or Blocklock controls can only be armed or disarmed by
those controls. It cannot be armed or disarmed using a control center.
The
Arm
menu allows the user to arm all areas, arm selected areas, or arm the control panel
area.
Notice!
For the system default, the area containing the control center is the local area. During
installation, each control center can be assigned to a specific area making that area the local
area for that control center. Therefore, the displayed button name on each control center is
unique for each installation. Depending on how your system is configured, you might need to
arm the control panel area first.
On the
Main Menu
(
Figure 1.5 Main Menu – screen 1, page 8
Arm
, then select an
arming option from the on-screen buttons (Arm All Areas, Arm Selected Areas, or Arm Control
Panel Area) on the Arm Menu (
). Selecting an area that is Ready
to Arm initiates the arming sequence and displays the Exit Delay screen (
) which indicates how much time you have to evacuate the arming area(s)
before your presence sets off an alarm. Selecting an area that is Not Ready to Arm displays an
Arming Failure screen (
Figure 2.7 Arming Failure screen, page 14
) which indicates which
area(s) can be force armed [armed by forcing bypass (refer to Section
) of all points that are not ready to be armed] and which areas cannot be
force armed.
Notice!
Force arming is not available when a related area must be armed first, when too many points
are already bypassed, or when an area contains specific unbypassable points.