![Bosch LBB 1920 Installation And Operating Manual Download Page 10](http://html.mh-extra.com/html/bosch/lbb-1920/lbb-1920_installation-and-operating-manual_37704010.webp)
Bosch Security Systems | 2003-09 | 3922 988 99482en
Plena Universal Pre-amplifier
| Installation and Operating Manual |
en
| 10
2.3 Setting emergency, insertion or cascade
The functionality of the insertion/cascade/emergency input is determined with jumper JP301 and the 'Ins/Casc'
switch at the back of the unit.
Input/output used for
Jumper JP301
Switch
Insertion
OFF
INS
Cascade
OFF
CASC
Emergency
ON
CASC
Note
If you use the emergency option, the emergency volume can be set with VR301. This volume is not affected
by the master volume.
Internal settings
Summary of Contents for LBB 1920