28 | KTS 530 / 540 / 570 (KTS 5 Series) | Decommissioning
en
6. Decommissioning
6.1
Temporary shutdown
In the event of lengthy periods of non-use:
6.2
Change of location
¶
If the KTS 530 / 540 / 570 (KTS 5 Series) is passed on,
all the documentation included in the scope of delivery
must be handed over together with the unit.
¶
The KTS 530 / 540 / 570 (KTS 5 Series) is only ever
to be transported in the original or equivalent pack-
aging.
¶
Unplug the electrical connection.
¶
Heed the notes on initial commissioning.
¶
Disconnect the KTS 530 / 540 / 570 (KTS 5 Series)
from the mains.
6.3
Disposal and scrapping
1.
Disconnect the KTS 530 / 540 / 570 (KTS 5 Series)
from the mains and detach the power cord.
2.
Dismantle the KTS 530 / 540 / 570 (KTS 5 Series)
and sort out and dispose of the different materials in
accordance with the applicable regulations.
6.4
Disposal
This KTS 530 / 540 / 570 (KTS 5 Series) is
subject to European guidelines 2012/19/EU
(WEEE).
Old electrical and electronic devices, includ-
ingcables and accessories or batteries must
be
disposed of separate to household waste.
¶
Please use the return and collection sys-
tems in place for disposal in your area.
¶
Damage to the environment and
hazards to personal health are pre-
vented by properly disposing of
KTS 530 / 540 / 570 (KTS 5 Series).
7. Technical data
7.1
General data
Property
Value/Range
Operating voltage
7 VDC — 30 VDC
Power consumption through vehicle bat-
tery or power supply
approx. 6 Watt
Dimensions (L x W x H)
170 x 120 x 40 mm
Weight (without connecting cables)
325 g
Degree of protection
IP 20
Operating temperature
5 °C – 40 °C
41 °F – 104 °F
Storage Temperature
-25 °C – 60 °C
-13 °F – 140 °F
Relative operating humidity
90 % non-
condensing
7.2
Interface protocols
The following interfaces with respective protocols are
supported for controller diagnosis in conformance with
ISO 15031:
R
ISO 9141-2 (Communications lines K and L)
R
SAE J1850VPW and SAE J1850PWM
(Communication lines BUS+ and BUS-)
R
CAN ISO 11898 ISO 15765-4 (OBD)
(Communication lines CAN-H and CAN-L)
R
CAN Single Wire
R
CAN Low Speed
7.3
Multimeter specifications
Measuring channel 1 (CH1)
zero potential
Measuring channel 2 (CH2)
potential based
Input resistance > 900 kOhm.
7.3.1
DC measurement (CH1 and CH2)
!
Use measuring leads for measurements smaller than
60 VDC, 30 VAC or 42 VACpeak only.
Property
Value/Range
Measurement range 200 mV — 60 V
Precision CH1
±0.75 % of measurement value,
additional ±0.25 % of measurement range
Precision CH2
±2 % of measurement value,
additional ±0.5 % of measurement range
Resolution
100 µV — 100 mV
(depending on measuring range)