- 9 -
Time-controlled arming
Description
The exit delay time must be entered by the
safety company in charge. Not in compliance
with VdS.
There are ______ seconds available for exit-
ing the premises before the system is armed.
Procedure
1. Call up the input field for time-controlled
arming. Press the center
key.
The input field for the time-controlled arm-
ing code will be displayed.
2. Start time-controlled arming.
Enter ID (1 to 3 digits) for ID 7, e.g. enter
007. Enter code (0 to 6 digits), e.g. 123123;
time-controlled arming starts automatically
after entry of the digits. Only press the
"ENTER" key if the code is < 6 digits.
3. Time-controlled arming is activated.
The delay time has started. The buzzer will
sound during the exit delay time. The room
must be exited within the programmed time
of ... seconds.
The left
key can be used to cancel the
arming procedure if needed.
4. Time-controlled arming is active.
After the door is closed, the system is
armed, which is indicated by a buzzer
sound of 3 seconds. The following mes-
sage will appear on the display.
15 : 13 22.11.2005
MENU
AREA
ARMED
ID: 007 CO:
_ _ _ _ _ _
AREA PROG.
ID:0 CO:
¾¾¾¾¾¾
AREA PROG.
ARMED IN . . . . . s
CANCEL
Time-controlled activation