5.13.1
Installation Considerations
For the best detector performance, select a mounting location
that is:
–
within 7.6 m (25 ft) of the protected glass
–
within clear view of the protected glass
–
at least 2 m (6.5 ft) from the floor
–
at least 1 m (3 ft) from forced-air ducts
–
at least 1 m (3 ft) from sirens or bells greater than 5 cm
(2 in.) in diameter
–
on a window frame if any heavy window covering is
present
Avoid mounting the detector:
–
in a corner
–
on the same wall as the protected glass
–
on free-standing posts or pillars
–
in rooms with noisy equipment such as air compressors,
bells, and power tools
5.13.2
Sensitivity Settings
1.
If the front housing is attached, carefully open the service
door (
Item 3
,
2.
Enable the EVENT and ALARM LEDs for test purposes by
sliding the LED ENABLE switch (
Item 8
in the direction of the arrow (above the switch).
An orange flag protrudes from the side of the detector.
3.
Use
to determine the appropriate sensitivity
setting for your application.
NOTICE!
Glass break detectors are intended only as a component of a
perimeter protection system. You should always use a motion
detector together with a glass break detector.