Bosch ISP-SM90-120 Instruction Manual Download Page 6

 

F.01U.331.565-01 

© 2016 Bosch Security Systems, Inc. 

13.

 

Service 

The function of the detector and its mounting should be 
checked at least once a year as follows: 

 

Functionally test the detector as detailed in section 12.1. 

 

Verify the settings of the detector by the control panel 
menu options. 

 

Check the mounting of the detector to ensure that the 
detector is securely attached. 

 

Check that there is a direct connection between the 
detector and the mounting surface. Paint, varnish, dirt, 
silicone or similar materials will impede the acoustics. 

Refer to local approvals for guidance on this matter. 

14.

 

Modular vaults 

The following principles must be strictly observed when 
using seismic detectors on modular vaults made from steel 
or concrete: 

 

Thickness from 100 to 400mm 

 

Width up to 1000mm 

 

Length up to 6500mm 

Modules with detector 
arrangement 

 

 

 

Corner joints between walls 
seamlessly welded 

Always 1 detector on 
doors 

 

 

1.

 

One detector for a maximum of 5 wall modules. The 
detector must be mounted on the middle module. 

2.

 

In addition to being bolted together, all of the joints 
between the modules must be welded every 400 − 
500mm with a 30 − 40mm seam. 

3.

 

Corner joints between wall modules must be seamlessly 
welded if the coverage area is to extend beyond the 
corners. 

4.

 

In the case of wall modules equipped with detectors, the 
immediately adjoining floor and/or ceiling modules can 
be included in the coverage area if the corresponding 
butt joints are seamlessly welded. 

5.

 

Where building vaults use modules of varying thickness, 
the butt joints must be seamlessly welded. 

6.

 

Avoid mounting detectors on modules to which guide 
rails for cassette transport lifts, ventilators or other 
mechanical equipment are attached. 

7.

 

Always equip modules which have a pay-in/withdrawal 
slot with a detector. This will also be able to monitor the 
adjacent modules. 

8.

 

All doors must always be equipped with a detector. 

9.

 

Programming: 

 

 Recommended 

setting 

On maximum 5 modules at a 
maximum height of 6.5m 

Concrete 4m 

On maximum 3 modules at a 
maximum height of 4m 

Concrete 2.5m 

On doors 

Steel 2m 

15.

 

Technical data 

Dimensions 

89mm x 89mm x 23mm 

Supply voltage (LSNi/LSN) 

Vmax. = 33 V DC 

Current consumption 
(LSNi/LSN) 

Ityp. = 1.2 mA 
Imax. = 1.625 mA 

Tamper monitoring: 

 

Microswitch, cover + 
removal 

Opens on sabotage 

 

External tamper contact 
(Fig.6, terminal 11) 

 

o

 

Closed resistor  < 20 kΩ 

o

 

Open resistor 

> 650 kΩ 

 

Anti-drilling foil in cover 
(optional) 

Damage = sabotage 

 

For sensitivity reduction  LOW < 1.5 V DC 

Operating temperature 

-25 ºC to +70 ºC 

Storage temperature 

-50 ºC to +70 ºC 

Air humidity (EN 60721), 
non-condensing 

< 95% 

Approvals 

See the type plate inside the 
detector cover (Fig. 5). 

16.

 

Ordering information 

ISP-SM90-120 
Seismic detector 

F.01U.173.560 

ISN-GMX-P0 
Mounting  

F.01U.003.366 

ISN-GMX-S1 
Internal test transmitter 

F.01U.003.371 

ISN-GMX-W0 
Wall/Ceiling recess box 

F.01U.003.372 

ISN-GMX-B0 
Floor recess box  

F.01U.003.365 

ISN-GMX-P3S 
Swivel plate  

F.01U.003.368 

ISN-GMX-P3SZ 
Swivel plate

F.01U.003.370 

ISN-GMA-S6

 

Movable mounting kit

F.01U.003.363 

ISN-GMX-D7 
Anti-drill foil (10x) 

F.01U.004.305 

 

de 

1.

 

EG-Konformitätserklärung 

Hiermit erklärt Bosch Security Systems, Inc. dass dieser 
Gerätetyp den Anforderungen aller relevanten EU-Richtlinien 
für die CE-Kennzeichnung entspricht. Ab dem 20.04.2016 

1 2 3 4 5 1 2 3 4 5  .  .  .  .

Summary of Contents for ISP-SM90-120

Page 1: ...F 01U 331 565 01 1 2016 Bosch Security Systems Inc ISP SM90 120 en Seismic detector de Körperschallmelder 11 2016 1 2 3 4 5 6 ...

Page 2: ...F 01U 331 565 01 2 2016 Bosch Security Systems Inc 7 ...

Page 3: ...ategy 4 1 Detector spacing distance Detectors should be positioned so that they cover the entire area to be monitored The distance between detectors is referred to as the spacing distance sd Detector spacing distance sd To ensure complete coverage of the protected area the following formula should be applied to determine the correct spacing distance between seismic detectors Spacing distance sd op...

Page 4: ...g 4 Secure the ISN GMX P0 to the steel expansion plug with the M6 x 47mm screw 5 Secure the ISN GMX S1 to the brass expansion plug with the M4 x 21mm screw 6 Mount the detector on to the ISN GMX P0 6 Mounting the detector 1 Remove the cover from the detector 2 Attach the detector to the prepared mounting base using the two mounting screws Fig 1 items I 3 Remove the cable access skirt Fig 5 4 Wire ...

Page 5: ...of the detector It is only possible to set the shock sensitivity for the mode and effective radius independently in USER MODE with the LSNi LSN control panel Mode Effective radius Shock sensitivity Example of use Concrete 5m High Vault Mode Effective radius Shock sensitivity Example of use Concrete 4m High Vault modular vault Concrete 2 5m High Vault modular vault Steel 2m Medium Armor plated safe...

Page 6: ...ts must be seamlessly welded 6 Avoid mounting detectors on modules to which guide rails for cassette transport lifts ventilators or other mechanical equipment are attached 7 Always equip modules which have a pay in withdrawal slot with a detector This will also be able to monitor the adjacent modules 8 All doors must always be equipped with a detector 9 Programming Recommended setting On maximum 5...

Page 7: ...bstand zwischen den Meldern wird als Melderabstand bezeichnet sd engl spacing distance Melderabstand sd Für eine vollständige Abdeckung des zu schützenden Bereichs sollte die folgende Formel angewendet werden um den korrekten Abstand zwischen den Körperschallmeldern zu bestimmen Melderabstand sd Wirkradius r 2 0 75 Beispiel Material Wirkradius Melderabstand Stahl 2m 3m Beton 4m 6m LWS Panzerungssy...

Page 8: ... Montage auf Beton darf der ISN GMX S1 keinen Kontakt mit der Montageplatte ISN GMX P0 haben Der ISN GMX S1 muss mithilfe der Schraube M4 21 mm und dem dazugehörigen Messingspreizdübel am Beton befestigt werden 4 Befestigen Sie die ISN GMX P0 mithilfe der Schraube M6 47 mm am Stahlspreizdübel 5 Befestigen Sie den ISN GMX S1 mit der Schraube M4 21 mm am Messingspreizdübel 6 Montieren Sie den Melder...

Page 9: ...lung reduziert Eine potentielle Anwendung ist die Verhinderung der Alarmauslösung bei starken funktionsbedingten Geräuschen 9 Programmierung über LSNi LSN Zentrale Die Programmierung des Melders erfolgt über die Konfigurationssoftware der entsprechenden Zentrale 10 Wirkradius Der angegebene Wirkradius gilt für einen Angriff mit Sauerstofflanze Bei einem Angriff mit mechanischem Werkzeug z B Bohrer...

Page 10: ... Thema 14 Elementtresore Beim Einsatz des Körperschallmelders in und an Elementtresoren aus Stahl und Betonmaterial sind folgende Grundsätze unbedingt zu beachten Stärke von 100 bis 400 mm Breite bis 1 000 mm Länge bis 6 500 mm Elemente mit Melderanordnung Eckverbindung Wand Wand durchgehend verschweißt Immer 1 Melder an Türen 1 Ein Melder für jeweils maximal 5 Wandelemente Der Melder muss auf dem...

Page 11: ...htigkeit EN 60721 nicht kondensierend 95 Zulassungen Siehe Typenschild auf Innenseite der Abdeckung Abb 5 16 Bestellangaben ISP SM90 120 Körperschallmelder F 01U 173 560 ISN GMX P0 Montageplatte F 01U 003 366 ISN GMX S1 Interner Prüfsender F 01U 003 371 ISN GMX W0 Wand Deckeneinbaudose F 01U 003 372 ISN GMX B0 Bodeneinbaudose F 01U 003 365 ISN GMX P3S Schlossschutz F 01U 003 368 ISN GMX P3SZ Schlo...

Page 12: ...1 1 1 0 1 1 209 1 1 0 1 0 0 0 1 38 0 0 1 0 0 1 1 0 124 0 1 1 1 1 1 0 0 210 1 1 0 1 0 0 1 0 39 0 0 1 0 0 1 1 1 125 0 1 1 1 1 1 0 1 211 1 1 0 1 0 0 1 1 40 0 0 1 0 1 0 0 0 126 0 1 1 1 1 1 1 0 212 1 1 0 1 0 1 0 0 41 0 0 1 0 1 0 0 1 127 0 1 1 1 1 1 1 1 213 1 1 0 1 0 1 0 1 42 0 0 1 0 1 0 1 0 128 1 0 0 0 0 0 0 0 214 1 1 0 1 0 1 1 0 43 0 0 1 0 1 0 1 1 129 1 0 0 0 0 0 0 1 215 1 1 0 1 0 1 1 1 44 0 0 1 0 1 1...

Reviews: