13.
Service
The function of the detector and its mounting should be
checked at least once a year as follows:
•
Functionally test the detector as detailed in section 12.1.
•
Verify the settings of the detector by the control panel
menu options.
•
Check the mounting of the detector to ensure that the
detector is securely attached.
•
Check that there is a direct connection between the
detector and the mounting surface. Paint, varnish, dirt,
silicone or similar materials will impede the acoustics.
Refer to local approvals for guidance on this matter.
14.
Modular vaults
The following principles must be strictly observed when
using seismic detectors on modular vaults made from steel
or concrete:
•
Thickness from 100 to 400mm
•
Width up to 1000mm
•
Length up to 6500mm
Modules with detector
arrangement
Corner joints between walls
seamlessly welded
Always 1 detector on
doors
1.
One detector for a maximum of 5 wall modules. The
detector must be mounted on the middle module.
2.
In addition to being bolted together, all of the joints
between the modules must be welded every 400 −
500mm with a 30 − 40mm seam.
3.
Corner joints between wall modules must be seamlessly
welded if the coverage area is to extend beyond the
corners.
4.
In the case of wall modules equipped with detectors, the
immediately adjoining floor and/or ceiling modules can
be included in the coverage area if the corresponding
butt joints are seamlessly welded.
5.
Where building vaults use modules of varying thickness,
the butt joints must be seamlessly welded.
6.
Avoid mounting detectors on modules to which guide
rails for cassette transport lifts, ventilators or other
mechanical equipment are attached.
7.
Always equip modules which have a pay-in/withdrawal
slot with a detector. This will also be able to monitor the
adjacent modules.
8.
All doors must always be equipped with a detector.
9.
Programming:
Recommended
setting
On maximum 5 modules at a
maximum height of 6.5m
Concrete 4m
On maximum 3 modules at a
maximum height of 4m
Concrete 2.5m
On doors
Steel 2m
15.
Technical data
Dimensions
89mm x 89mm x 23mm
Supply voltage (LSNi/LSN)
Vmax. = 33 V DC
Current consumption
(LSNi/LSN)
Ityp. = 1.2 mA
Imax. = 1.625 mA
Tamper monitoring:
•
Microswitch, cover +
removal
Opens on sabotage
•
External tamper contact
(Fig.6, terminal 11)
o
Closed resistor < 20 kΩ
o
Open resistor
> 650 kΩ
•
Anti-drilling foil in cover
(optional)
Damage = sabotage
•
For sensitivity reduction LOW < 1.5 V DC
Operating temperature
-25 ºC to +70 ºC
Storage temperature
-50 ºC to +70 ºC
Air humidity (EN 60721),
non-condensing
< 95%
Approvals
See the type plate inside the
detector cover (Fig. 5).
16.
Ordering information
ISP-SM90-120
Seismic detector
F.01U.173.560
ISN-GMX-P0
Mounting
F.01U.003.366
ISN-GMX-S1
Internal test transmitter
F.01U.003.371
ISN-GMX-W0
Wall/Ceiling recess box
F.01U.003.372
ISN-GMX-B0
Floor recess box
F.01U.003.365
ISN-GMX-P3S
Swivel plate
F.01U.003.368
ISN-GMX-P3SZ
Swivel plate
F.01U.003.370
ISN-GMA-S6
Movable mounting kit
F.01U.003.363
ISN-GMX-D7
Anti-drill foil (10x)
F.01U.004.305