Installation - Accessories
4
17
Bosch Security Systems
Seismic Detectors Application Guide
I-200153-1
04.2016
4
Installation - Accessories
4.1
GMXP0 mounting plate
Figure 4-1:GMXP0 mounting plate
The GMXP0 is used to provide a secure connection between the detector and the protected sur-
face.
The GMXP0 is a double-sided metal plate suitable for welding, screwing or gluing to the protected
surface.
The GMXP0 is mandatory for installations on uneven steel, reinforced steel and concrete surfaces.
4.2
GMXS1 internal test transmitter
Figure 4-2: GMXS1 internal test transmitter
The GMXS1 internal test transmitter is installed with a detector. The GMXS1 enables a user to test
the detector from an external source, via a switched input. Testing is usually performed from the
intruder panel but it may also be performed from another source.
Activation of the GMXS1 is interpreted by the detector as a thermal lance attack as this form of at-
tack is the most difficult to detect.
The GMXS1 must be installed in the recommended location in close proximity to the seismic detec-
tor to enable a good acoustic connection between the test transmitter and the detector. The loca-
tion of the GMXS1 is determined by the drill template or the mounting plate. In both cases, the
GMXS1 is located under the cover of the ISN-SM-xx detector.
The GMXS1 may be used for both steel and concrete applications.