9
Photobeam 5000
Installation | en
3
Installation
Prior to installing the devices, please review the installation considerations below:
–
Install in an area that is clear of objects
–
Install the transmitter/receiver within the maximum protection range of the model
–
Do not install:
–
Receivers into intense sources of light (for example, rising and setting sun)
–
On movable surfaces subject to vibrations
–
Detectors where immersion to water, corrosive liquids, or exposure to high levels of
dust can occur
–
Detectors in close proximity to strong electromagnetic noises
–
Do not use detectors with other photobeam detectors or receivers
–
Do not disassemble or modify this detector
–
Do not install while the power is on
–
Avoid extreme temperature and humidity ranges as defined in the products specifications
–
Avoid installing detectors near magnets and/or magnetized materials
–
Avoid beam interference between other units when multiple units are installed
–
Use the selectable beam’s feature when stacking detectors
3.1
Beam spread
The beam spread angle is ±0.7 °from the transmitter to the receiver. Refer to the diagram and
table below to determine the installation conditions.
1
5
4
3
2
Figure 3.1: Beam distance and spread
Callout
﹘
Description
Callout
﹘
Description
1
ー
Transmitter
4
ー
Receiver
2
ー
Horizontal spread (B)
5
ー
Distance (A)
3
ー
Vertical spread (C)
Bosch Security Systems, Inc.
Installation and Operation Guide
2016.02 | 03 | F.01U.303.478
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]