3.2
10
en | Installation
Photobeam 5000
Distance, horizontal and vertical spread values: (A) / (B) / (C)
Metric
Imperial unit
20 m / 0.5 m / 0.8 m
65 ft / 1.6 ft / 2.6 ft
40 m / 1.0 m /1.3 m
13.1 ft / 3.2 ft / 4.2 ft
60 m / 1.5m / 1.8 m
196 ft / 4.9 ft / 5.9 ft
80 m / 2.0 m / 2.2 m
262 ft / 6.5 ft / 7.2 ft
100 m / 2.5 m / 2.7 m
328 ft / 8.2 ft / 8.8 ft
120 m / 3.0 m / 3.2 m
393 ft / 9.8 ft / 10.4 ft
140 m / 3.5 m / 3.7 m
459 ft / 11.4 ft / 12.1 ft
160 m / 4.0 m / 4.2 m
524 ft / 13.1 ft / 13.7 ft
180 m / 4.5 m / 4.7 m
590 ft / 14.7 ft / 15.4 ft
200 m / 5.0 m / 5.2 m
656 ft / 16.4 ft / 17.0 ft
Pole mount installation
1
2
Figure 3.2: Pole mounting view
Callout
﹘
Description
Callout
﹘
Description
1
ー
Diameter 38.0 – 42.7 mm (1.50 – 1.68
2
ー
Back-to-back pole mounting
in)
Attaching the mounting bracket:
1.
Choose an appropriate mounting location for the devices. Install the mounting poles with
a clear line-of-sight between the transmitter and receiver.
2.
Loosen the transmitter’s cover mounting screw and remove the cover.
3.
Loosen the two base mounting screws and remove the mounting plate by sliding it down.
4.
Attach the mounting hardware to the mounting plate using the clamping screws. Refer to
the figure below.
2016.02 | 03 | F.01U.303.478
Installation and Operation Guide
Bosch Security Systems, Inc.
Available from A1 Security Cameras