11.0  Fault Analysis Mode 

If a fault occurs, the FAULT or MAINS indicators 
flash and the codepad beeps once every min. 

11.1 AC 

Fail 

If the AC MAINS supply fails, the MAINS indicator 
flashes until the AC MAINS supply is restored. 
Pressing [#] once acknowledges the fault and stops 
the codepad from beeping once every min. 

11.2 System 

Faults 

To determine all system faults other than the AC 
MAINS supply, enter Fault Analysis Mode: 
1.

 

Hold down [5] until two beeps sound. 
The FAULT indicator lights steadily and the 
STAY and AWAY indicators flash in unison. 
Any lit zone indicators indicate the type of fault 
that occurred. Refer to 

Table 9 

for the list of 

system faults that can occur. 

2.

 

To further determine the type of fault condition, 
hold down the key that corresponds to the lit 
zone indicator. 

3.

 

To exit from Fault Analysis Mode and return to 
the disarmed state, press [#].  
The FAULT indicator remains lit and the 
codepad stops beeping once per min. 

11.3 Fault 

Descriptions 

 

Table 9:  Fault Condition Indicators 

 

 

Zone LED 

FAULT Condition 

Battery Fail 

2 Date/Time 

Sensor Watch 

Horn Speaker Fail 

Telephone Line Fail 

6 EEPROM 

Fail 

AUX Power Supply Fail 

8 Communication 

Fail 

 

Battery Fail 

A battery fail fault registers when the system detects 
a low capacity backup battery. The system 
automatically performs a Battery Test every 4 hours 
and every time the system is armed. 

Date and Time 

The date and time fault registers every time the 
system powers down. This type of fault does not 
cause the FAULT indicator to display on the 
codepad unless your installer programmed the 
automatic arming time. Refer to 

Section 10.0 Setting 

the Date and Time

 to program the date and time. 

Sensor Watch Fail 

A sensor watch fault registers because one or more 
detection devices failed to notice any movement 
during the disarmed state for the time period 
programmed by your installer. The fault clears when 
the zone in question detects movement and is reset. 

While in Fault Analysis Mode, hold down [5] until 
two beeps sound.  
The indicator corresponding to the faulted zone 
lights. 

Horn Speaker Fail 

A horn speaker failure fault registers when the 
system detects the horn speaker is disconnected. This 
fault clears once the horn speaker is reconnected. 
Your installer must program the system for this 
feature to operate. 

Telephone Line Fail 

A telephone line failure fault registers when the 
system detects the telephone line is disconnected 
from the control panel. Your installer must program 
the system for this feature to operate. 

EEPROM Fault 

An EEPROM failure fault registers when the system 
detects an internal checksum error. Contact your 
installer if this fault occurs. 

AUX Power Supply Fail 

An AUX power supply failure fault occurs when 
either of the two 1 A AUX power supplies fail. 
Contact your installer if this fault occurs. 

Communication Fail 

A communication fail fault registers when the control 
panel fails to communicate with the receiving party 
(for example, a monitoring company, mobile phone, 
pocket pager, and so on). The communication fault 
clears after the control panel successfully reports to 
the receiving party. 

12.0  Telco Arm/Disarm 

Sequence (Call Forward 
On/Off) 

12.1  Telco Arm Sequence 

Use this section to program the Call Forward – 
Immediate On sequence or Call Forward – No 
Answer sequence to automatically operate when you 
arm the system in AWAY Mode. This feature is only 
available if your telecommunications provider has 
the call-forward option. 

 

The examples given in this feature are 
only applicable to Australia. 

 

Summary of Contents for ICP-CC404

Page 1: ...EN User s Guide ICP CC404 Control Panel ICP CC404 ...

Page 2: ...connect this equipment should it become physically damaged and arrange for its disposal or repair The transmit level from this device is set at a fixed level and because of this there may be circumstances where the performance is less than optimal Before reporting such occurrences as faults please check the line with a standard telepermitted telephone and do not report a fault if the telephone per...

Page 3: ... 0 Turning Outputs On Off 12 14 0 Reset Latching Outputs 12 15 0 Codepad ID Buzzer Tone Change 12 16 0 Testing 13 16 1 Horn Speaker Test 13 16 2 Bell Test 13 16 3 Strobe Test 13 16 4 Walk Test Mode 13 16 5 Test Report 13 17 0 Event Memory Recall 13 18 0 Day Alarm 13 19 0 Remote Arming By Telephone 13 20 0 Domestic Dialing 14 20 1 Acknowledging Domestic Calls 14 20 2 Programming Domestic Telephone ...

Page 4: ... be tailored to meet all requirements quickly and easily 2 0 Features The ICP CC404 Control Panel uses the latest in microprocessor technology to provide you with more useful features and superior reliability and performance The main features of the control panel are Eight programmable User Codes STAY Mode and AWAY Mode operation Four programmable burglary zones Four programmable 24 hour zones Sir...

Page 5: ...ally isolated or selected to be isolated 3 2 AWAY Indicator The AWAY indicator shows the system is armed in AWAY Mode The AWAY indicator also flashes in unison with the STAY indicator when programming the control panel Refer to Section 4 1 Arming in AWAY Mode on page 7 for information on the different methods of arming the system in AWAY Mode Table 2 AWAY Indicator Status Definition On System is a...

Page 6: ...n the codepad or end of Exit Time occurred when armed in STAY Mode 1 or STAY Mode 2 Two short beeps The system accepted your code Three short beeps The system executed the requested function One long beep Indicates the end of Exit Time when armed in AWAY Mode or the requested operation was denied or aborted One beep every sec Walk Test Mode is currently active or it is a warning before automatic a...

Page 7: ...TAY Mode 1 is programmed and a zone not automatically isolated is activated the codepad beeps twice per sec until the entry timer expires or the system is disarmed If the alarm condition is not reset by entering your user code and pressing for example 2 5 8 0 before the entry timer expires the sirens sound an alarm Only your installer can program this feature To arm in STAY Mode 1 using the first ...

Page 8: ...e system To add a user code 1 Enter your four character Master Code and press 1 for example 2 5 8 0 1 Three beeps sound and the STAY and AWAY indicators flash 2 Enter the user code number 1 to 8 and press for example 2 for User 2 or 8 for User 8 Two beeps sound and the selected user number appears on the codepad indicators 3 Enter the digits required for the new code and press for example for user...

Page 9: ...r or operate the blue strobe light These indications allow you to operate the system from outside the premises with confidence Table 8 Keyfob Audible and Visual Indications Indication Definition One beep System disarmed Two beeps System armed in AWAY Mode Two tone beep System armed in STAY Mode 3 sec strobe System disarmed 6 sec strobe System armed in AWAY or STAY Mode 8 0 Alarms 8 1 Duress Alarm ...

Page 10: ...ess for example 1 for Zone 1 or 2 for Zone 2 Each zone to isolate has a corresponding zone indicator that flashes If you selected an incorrect zone to isolate enter the incorrect zone number again and press Repeat Step 2 if you are isolating more than one zone until all zones you want to isolate are selected 3 Press after you isolate all selected zones Two beeps sound and the system returns to the...

Page 11: ...n 10 0 Setting the Date and Time to program the date and time Sensor Watch Fail A sensor watch fault registers because one or more detection devices failed to notice any movement during the disarmed state for the time period programmed by your installer The fault clears when the zone in question detects movement and is reset While in Fault Analysis Mode hold down 5 until two beeps sound The indica...

Page 12: ... press 3 for example 2 5 8 0 3 Three beeps sound and the STAY and AWAY indicators flash 2 Press 2 to select the Telco Disarm Sequence Three beeps sound 3 Enter the call forward disable sequence for example 6 1 to disable the No Answer Call Forward sequence or 2 1 to disable the Call Forward Immediate sequence To program a in the Telco Disarm Sequence enter 2 4 Press when finished Two beeps sound a...

Page 13: ...between arming the system in STAY Mode 1 or STAY Mode 2 To enter Event Memory Enter your four character Master Code and press 8 for example 2 5 8 0 8 Three beeps sound The last 40 events appear one at a time by the codepad indicators starting from the most recent event A beep sounds as each event appears 18 0 Day Alarm Day alarm allows the system to monitor a combination of zones when the system i...

Page 14: ...er 2 min and calls the next telephone number Press for 1 to 3 sec during the pause to acknowledge the call If you acknowledge the call the control panel does not call any more phone numbers for that event If the call is successfully acknowledged a tone of decreasing pitch sounds Table 11 Domestic Dialing Telephone Digits Digit Required Number to Program Digit Required Number to Program 0 0 8 8 1 1...

Page 15: ... 1 Alarm The corresponding zone is unsealed and in alarm 2 Bypassed A system operator manually isolated the corresponding zone Refer to Section 9 0 Isolating Zones for information about manually isolating a zone s before arming the system 3 Trouble A zone was unsealed when Exit Time expired System Status The system status information is divided into the four digits identified in Table 13 Table 13 ...

Page 16: ...10 08 F01U089400 01 Figure 6 Basic Pager Display 1 Subscriber ID number 2 Zone status 3 System status 4 0 Zone Normal 1 Alarm 2 Manually Isolated 5 8 Disarmed 9 Armed 6 0 Normal 1 Panic Duress 2 Fire Alarm 3 Medical Alarm 7 0 AC Normal 1 AC Failure 8 0 System Normal 1 System Fault ...

Page 17: ...n Dynamic Battery Testing Monitors and tests the condition of your backup battery Entry Time or Entry Delay The time allowed by a zone to disarm the system after you enter your premises External Equipment Any devices connected to your system such as detectors codepads and sirens Forced Arming Enables you to arm your system even though one or more zones are unsealed Handover Delay The system is arm...

Page 18: ...lates zones when you arm the system in STAY Mode 2 Only the Master Code holder can program zones to be isolated automatically in this mode Telco Arm Sequence Telco arming automatically diverts your telephone number to another telephone when the system is armed in AWAY Mode In Australia this feature is called Call Forward Telco Disarm Sequence Telco disarming automatically calls the telephone excha...

Page 19: ...0 Installation Notes Bosch Security Systems Inc 10 08 F01U089400 01 19 23 0 Installation Notes Company Name Technician s Name Technician s Telephone Number Installation Date Warranty Expires Panel Software Version Service Notes ...

Page 20: ...Mode 1 or are programmed for day alarm operation Isolated In STAY Mode 1 Day Alarm Enabled Zone 1 Zone 2 Zone 3 Zone 4 User Code Names Master Code Default 2580 User Code 1 Y User Code 9 User Code 2 User Code 10 User Code 3 User Code 11 User Code 4 User Code 12 User Code 5 User Code 13 User Code 6 User Code 14 User Code 7 User Code 15 User Code 8 User Code 16 ...

Page 21: ...ng AWAY Mode YES NO Automatic Arming Time AM PM Automatic Arming STAY Mode YES NO Automatic Disarming Time AM PM Output Descriptions Output 1 Output 3 Output 2 Output 4 Isolating Method Standard Isolating YES NO Code To Isolate YES NO Communication Options Back To Base Reporting YES NO Domestic Reporting YES NO Domestic Reporting Number Of Beeps Other System Information Siren Run Time Minutes Sens...

Page 22: ... mA Current Draw In Alarm with Codepad 105 mA Backup Battery 6 Ah 12 VDC Rechargeable sealed lead acid battery Dimensions case packed in carton 30 6 cm x 26 2 cm x 8 4 cm 12 1 in x 10 3 in x 3 3 in Weight 2 5 kg 5 5 lb Supplier Code N771 New Zealand Telepermit PTC 211 98 085 The ICP CC488 Control Panel is designed to comply with A Tick Test the sirens strobe and zones at weekly intervals Refer to ...

Page 23: ...ICP CC404 User s Guide Notes Bosch Security Systems Inc 10 08 F01U089400 01 23 Notes ...

Page 24: ...ICP CC404 User s Guide Notes Notes ...

Page 25: ...ICP CC404 User s Guide Notes Bosch Security Systems Inc 10 08 F01U089400 01 25 Notes ...

Page 26: ...Time 17 Entry Guard Timer 7 Event Memory Recall 13 External Equipment 17 Fault Analysis 11 Fault Description AC Mains Fail 11 AUX Power Supply Fail 11 Battery Fail 11 Date and Time 11 EEPROM Fault 11 Horn Speaker Fail 11 Sensor Watch Fail 11 Telephone Line Fail 11 Fault Descriptions 11 Communciation Fail 11 System Fault 11 FAULT Indicator 6 Features 4 Fire Alarm 10 Forced Arming 7 17 Hand Held Rem...

Page 27: ...ICP CC404 User s Guide Index Bosch Security Systems Inc 10 08 F01U089400 01 27 Zone Indicators 5 Zones 18 ...

Page 28: ... 2008 Bosch Security Systems Inc F01U089400 01 ...

Reviews: