8 716 473 071 (2015/04)
HydroPower
Technical Characteristics and Dimensions | 7
2.7
Electrical scheme
Fig. 3
[1] Main Solenoid Valve
[2] Diaphragm Switch
[3] Pilot Solenoid Valve
[4] Ionisation electrode (Flame Rod)
[5] Ignition electrode (Spark Electrode)
[6] Temperature limiter
[7] Hydrogenerator
[8] LED (green)
[9] LED (red)
2.8
Technical characteristics
4
5
3
1
2
9
6
8
S
HV
9708069951-11.1V
7
Technical characteristics
Units
TF250H / 10H
TF325H / 13H
TF400H / 16H
Gas Consumption
Nominal Gas Consumption
MJ/h
79
104
130
Supply pressure flowing
Natural gas (When operating)
kPa
1.13
1.13
1.13
LP gas (When operating)
kPa
2.75
2.75
2.75
Number of injectors
12
14
18
Water data
Maximum permissible pressure (Static)
kPa
800
800
800
Temperature selector in fully clockwise position
Temperature rise (Above incoming water temperature)
°C
50
50
50
Water flow range (Litres per minute)
l/min
3.2 to 5
3.2 to 6.5
3.2 to 8
Minimum operating water pressure
kPa
30
40
50
Minimum constant water pressure for minimum flow
kPa
60
100
130
Table 5