background image

8

Electrical Installation - GROUNDING INSTRUCTIONS

The models stated on the front cover are either dual-

rated, designed to be connected to either 208/240V AC, 

60 Hz, 4-wire, single-phase power supply, or rated at 

120V AC, 60 Hz and use a NEMA 5-20 plug to connect 

to a dedicated 120 V microwave circuit.
208/240 V models may also be combined with some 

Bosch Built-in Ovens and can be connected directly to 

the combo appliance. To do this, please refer to detailed 

instructions with the Bosch Combination Kit.

9

WARNING

When connected to a 4 or 5-wire, 120/208-Volt 3-

phase power supply, the phase C conductor is not 

required for the operation of the appliance.

Electrical Connection with Plug

HMC80152UC
HMC87152UC

Electrical Requirements:

a three prong grounded outlet

120 V, 60 Hz, AC only

20 Amp electrical supply with a fuse or a circuit 

breaker

This product must be connected to a supply circuit of the 

proper voltage and frequency. Wire size must conform to 

the requirements of the National Electric Code or the 

prevailing local code for this rating. The power supply 

cord and plug should be brought to a separate 20-amp 

branch circuit single grounded outlet. The outlet box 

should be located in the area behind the appliance (see 

section 

Cabinet Dimensions

). The outlet box and supply 

circuit should be installed by a qualified electrician and 

conform to the National Electrical Code or the prevailing 

local code.
The voltage used must be the same as specified on this 

microwave oven. Using a higher voltage is dangerous 

and may result in a fire or oven damage. Using a lower 

voltage will cause slow cooking. The manufacturer is not 

responsible for any damages resulting from the use of 

the oven with any voltage other than specified.

Electrical Connection with Wire Conduit

HMC80252UC
HMCP0252UC

The electrical supply should be a 4-wire single-phase AC. 

Install a suitable conduit box (not furnished). An 

appropriately-sized, UL-listed conduit connector must be 

used to correctly attach the conduit to the junction box.

9

WARNING

Local codes may vary; installation, electrical 

connections and grounding must comply with all 

applicable local codes.

If local codes permit grounding through the electrical 

supply neutral, connect both the white neutral wire and 

the bare ground wire from the oven to the white neutral 

electrical supply wire.

Electrical Connection

The four-wire connection is preferred, but where local 

codes permit, the three wire connection is also 

acceptable.

9

WARNING

When connected to a 4 or 5-wire, 120/208-Volt 3-

phase power supply, the phase C conductor is not 

required for the operation of the appliance.

Four-wire Connection
Ungrounded Neutral

Connect the red oven wire to the red electrical supply 

wire (hot wire).

Connect the black oven wire to the black electrical 

supply wire (hot wire).

Connect the white neutral oven wire to the white 

neutral (not bare or green ground) electrical supply 

wire.

Connect the green ground oven wire to the bare or 

green ground electrical supply wire.

Model

Connection

Circuit 

Requirements

HMCP0252UC

4 wire conduit 

cable

208 V, 

60 Hz

20 Amps

240 V, 

60 Hz

20 Amps

HMC80252UC

4 wire conduit 

cable

208 V, 

60 Hz

20 Amps

240 V, 

60 Hz

20 Amps

HMC80152UC

NEMA 5-20

120 V,  

60 Hz 

20 Amps

HMC87152UC

NEMA 5-20

120 V,  

60 Hz

20 Amps

SRZHUVXSSO\

MXQFWLRQER[

UHGZLUHV

JUHHQRUEDUH

JUHHQZLUH

8/OLVWHG

FDEOHIURP

ZKLWHZLUHV

EODFNZLUHV

ZLUH

FRQQHFWRU

RYHQ

Summary of Contents for HMC80152UC

Page 1: ...Installation Manual Built In Convection Microwave Oven Speed Oven 800 SERIES HMC87152UC HMC80152UC HMC80252UC HMCP0252UC ...

Page 2: ...tallation GROUNDING INSTRUCTIONS 8 Electrical Connection with Plug 8 Electrical Connection with Wire Conduit 8 Install Appliance 9 Mount to Cabinet 9 Testing Operation 9 Bosch Support 10 Before Calling Service 10 Data Plate 10 Service 10 Parts and Accessories 10 Safety Definitions 9 WARNING This indicates that death or serious injuries may occur as a result of non observance of this warning 9 CAUT...

Page 3: ...upply before attempting the installation For appliances equipped with a cord and plug do not cut or remove the ground prong It must be plugged into a matching grounding type receptacle to avoid electrical shock If there is any doubt as to whether the wall receptacle is properly grounded the customer should have it checked by a qualified electrician If required by the National Electrical Code or Ca...

Page 4: ...wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded For a permanently connected appliance This appliance must be connected to a grounded metallic permanent wiring system or an equipment grounding conductor should be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance Related Equipment Safe...

Page 5: ...quirements 2 Move the appliance into place in front of the cabinet opening Section Removing Packaging 3 Remove packaging materials leaving the bottom packaging on the appliance to avoid damage to the floor Section Removing Packaging 4 Team lift the appliance directly into the cabinet cutout Section Install Appliance Mount to Cabinet 5 Slide the appliance all the way into place Section Install Appl...

Page 6: ...ned If necessary you can elevate the appliance position by adding a panel in the required thickness on top of the supporting base The supporting base must be level and securely fixed to the cabinet Outlet Area Anywhere within the shaded area the minimal distance between the appliance and the wall is 1 in 45 mm Appliances with plug connection The outlet can be located anywhere within the shaded are...

Page 7: ...lbs 64 1 kg Under counter dimensions 27 units Flush installation 27 units Flush installation also requires two side cleats to be attached inside the cabinet frame recessed from the front a 5 16 8 mm baseplate underneath the unit body ê ë ë é 0HDVXUHPHQWV LQ LQFKHV PP 7RS YLHZ 6LGH YLHZ ê OXVK LQVHW GHSWK OHDWV OHDWV FOHDWV RSHQLQJ FXW RXW KHLJKW IOXVK FXW RXW KHLJKW EDVHSODWH ʌ ʓʘ ʎ ʚ ʎ ʚ ê é é ê ...

Page 8: ... slow cooking The manufacturer is not responsible for any damages resulting from the use of the oven with any voltage other than specified Electrical Connection with Wire Conduit HMC80252UC HMCP0252UC The electrical supply should be a 4 wire single phase AC Install a suitable conduit box not furnished An appropriately sized UL listed conduit connector must be used to correctly attach the conduit t...

Page 9: ...ble 2 Screw the appliance into place Testing Operation 1 Turn on power at the breaker 2 For Model HMC80252UC and HMCP0252UC Check power at junction box using a volt meter For 240 V installation the reading between the red and black wires line to line should be 220 to 240 volts For 208 V installation the reading between the red and black wires line to line should be 190 to 208 volts 3 For all model...

Page 10: ...r items needed in the spaces provided below Keep your invoice or escrow papers for warranty validation if service is needed Service We realize that you have made a considerable investment in your kitchen We are dedicated to supporting you and your appliance so that you have many years of creative cooking Please don t hesitate to contact our Customer Support Department if you have any questions or ...

Page 11: ...1901 Main Street Suite 600 Irvine CA 92614 800 944 2904 www bosch home com 2016 BSH Home Appliances 960901 9001152481 9001152481 ...

Reviews: