background image

 English | 

13

Bosch Power Tools

1 618 C00 51C | (7.5.12)

f

Do not operate the measuring tool in explosive environ-

ments, such as in the presence of flammable liquids, 

gases or dusts. 

Sparks can be created in the measuring 

tool which may ignite the dust or fumes.

f

Always set up the measuring tool in such a manner that 

the laser beams run far above or below eye level. 

This 

ensures that damage to the eyes will not occur.

f

Mark the area in which the measuring tool is being used 

with suitable laser warning labels. 

This prevents per-

sons not involved from accessing the danger area.

f

Do not store the measuring tool at locations, to which 

unauthorised persons have access. 

Persons not familiar 

with the operation of the measuring tool can cause harm to 

themselves and to others.

f

When using a class 3R measuring tool, observe possi-

ble national regulations. 

Non-observance of these regu-

lations can lead to injury.

f

Make sure that the area of laser radiation is monitored 

or shielded. 

The limitation of laser radiation to controlled 

areas prevents eye damage to persons not involved.

f

Before any work on the measuring tool itself (e.g. as-

sembling, maintenance, etc.) as well as when trans-

porting and storing, remove the battery pack or the 

batteries from the measuring tool. 

Danger of injury when 

accidentally actuating the On/Off switch.

f

Do not open the battery pack. 

Danger of short-circuiting.

Protect the battery pack against heat, e.g., 

against continuous intense sunlight, fire, 

water, and moisture. 

Danger of explosion.

f

When battery pack is not in use, keep it away from oth-

er metal objects like paper clips, coins, keys, nails, 

screws, or other small metal objects that can make a 

connection from one terminal to another. 

 Shorting the 

battery terminals together may cause burns or a fire.

f

Under abusive conditions, liquid may be ejected from 

the battery pack; avoid contact. If contact accidentally 

occurs, flush with water. If liquid contacts eyes, addi-

tionally seek medical help. 

Liquid ejected from the bat-

tery pack may cause irritations or burns.

f

In case of damage and improper use of the battery 

pack, vapours may be emitted. Provide for fresh air and 

seek medical help in case of complaints. 

The vapours 

can irritate the respiratory system.

f

Recharge only with the charger specified by the manu-

facturer. 

A charger that is suitable for one type of battery 

pack may create a risk of fire when used with another bat-

tery pack.

f

Use the battery pack only in conjunction with your 

Bosch measuring tool. 

This measure alone protects the 

battery pack against dangerous overload.

f

Use only original Bosch battery packs with the voltage 

listed on the nameplate of your measuring tool. 

When 

using other battery packs, e.g. imitations, reconditioned 

battery packs or other brands, there is danger of injury as 

well as property damage through exploding battery packs.

Keep the measuring tool and the laser tar-

get plate 10 away from cardiac pacemak-

ers. 

The magnets of the measuring tool and 

laser target plate generate a field that can im-

pair the function of cardiac pacemakers.

f

Keep the measuring tool and the laser target plate 10 

away from magnetic data medium and magnetically-

sensitive equipment. 

The effect of the magnets of the 

measuring tool and laser target plate can lead to irreversi-

ble data loss.

Remote control (GSL 2 Set)

Read and observe all instructions. 

SAVE 

THESE INSTRUCTIONS FOR FUTURE REFER-

ENCE.

f

Have the remote control repaired only through a quali-

fied repair person and only using identical replacement 

parts. 

This will ensure that the functionality of the remote 

control is maintained.

f

Do not operate the remote control in explosive atmos-

pheres, such as in the presence of flammable liquids, 

gases or dusts. 

Sparks can be created in the remote con-

trol which may ignite the dust or fumes.

Product Description and 

Specifications

While reading the operating instructions, unfold the graphics 

page with the illustration of the surface laser and the remote 

control, and leave it open.

Intended Use

Surface laser

The measuring tool is intended for checking the flatness of 

floor surfaces.
The measuring tool is suitable for indoor use.

Remote control (GSL 2 Set)

The remote control is intended for controlling surface lasers 

indoors.

Product Features

The numbering of the product features refers to the illustration 

of the surface laser and remote control on the graphics page.

Surface laser

1

Exit opening for laser beam

2

Laser warning label

3

Handle

4

Reception lens for remote control (GSL 2 Set)

5

Battery status indicator

6

Latch of battery lid

7

Battery lid

8

On/Off switch

9

Thumbwheel for height adjustment

10

Laser target plate

11

Measuring tip of the laser target plate

OBJ_BUCH-1545-004.book  Page 13  Monday, May 7, 2012  9:33 AM

Summary of Contents for GSL Professional

Page 1: ...ginal driftsinstruks fi Alkuperäiset ohjeet el Ðñùôüôõðï ïäçãéþí ñÞóçò tr Orijinal işletme talimat pl Instrukcja oryginalna cs Původní návod k používání sk Pôvodný návod na použitie hu Eredeti használati utasítás ru Îðèãèíàëüíîå ðóêîâîäñòâî ïî ýêñïëóàòàöèè uk Îðèã íàëüíà íñòðóêö ÿ ç åêñïëóàòàö ro Instrucţiuni originale bg Îðèãèíàëíà èíñòðóêöèÿ sr Originalno uputstvo za rad sl Izvirna navodila hr O...

Page 2: ...3 1 618 C00 51C 7 5 12 Bosch Power Tools Off Off Off On On On GSL 2 1 11 10 9 8 2 2 6 7 12 4 5 3 OBJ_BUCH 1545 004 book Page 3 Monday May 7 2012 9 14 AM ...

Page 3: ...1 618 C00 51C 7 5 12 Bosch Power Tools 4 17 18 19 13 16 15 14 6 7 6 23 7 22 21 20 RC 2 E D C B A OBJ_BUCH 1545 004 book Page 4 Monday May 7 2012 9 14 AM ...

Page 4: ...C 7 5 12 Bosch Power Tools 10 10 8 V 2 607 336 014 24 1 618 C00 470 25 2 608 438 693 1 608 M00 70B AL 1115 CV 3 6 10 8 V 2 607 225 514 EU 2 607 225 516 UK H G F OBJ_BUCH 1545 004 book Page 5 Monday May 7 2012 9 14 AM ...

Page 5: ...t Seite 12 Änderungen vorbehalten English Safety Notes Surface laser Working safely with the measuring tool is possibleonlywhentheoperatingandsafety information are read completely and the instructions contained therein are strictly followed Nevermakewarninglabelsonthe measuring tool unrecognisable SAVE THESE INSTRUCTIONS f Caution The use of other operating or adjusting equipment or the applicati...

Page 6: ...y the manu facturer A charger that is suitable for one type of battery pack may create a risk of fire when used with another bat tery pack f Use the battery pack only in conjunction with your Bosch measuring tool This measure alone protects the battery pack against dangerous overload f Use only original Bosch battery packs with the voltage listed on the nameplate of your measuring tool When using ...

Page 7: ...ly 5 s 5 s Operating temperature 10 C 50 C 10 C 50 C Storage temperature 20 C 70 C 20 C 70 C Relative air humidity max 90 90 Laser class 3R 3R Laser type 630 670 nm 5 mW 630 670 nm 5 mW C6 1 1 Batteries alkali manganese Battery pack lithium ion 4 x 1 5 V LR06 AA 10 8 V 4 x 1 5 V LR06 AA 10 8 V Battery life Batteries alkali manganese Battery pack lithium ion 15 h 15 h 15 h 15 h Weight according to ...

Page 8: ...ebatterypack23 pressonthelatch6andfoldthe battery lid 7 up Slide the charged battery pack completely in to the battery compartment and close the battery lid To remove the battery pack 23 press on the latch 6 and fold the battery lid 7 up Pull the battery pack out of the battery compartment Battery status Indicator ThethreegreenLEDsofbatterystatusindicator5indicatethe charge condition of the batter...

Page 9: ...chang es are the case Upon re levelling check if the two laser beams are aligned at the reference point see Aligning the Height of the Measuring Tool page 16 in order to avoid ver tical errors Aligning the Height of the Measuring Tool The measuring tool generates two laser beams that can be seen on the floor surface in front of the measuring tool for dis tances beyond 50 cm The beams must be broug...

Page 10: ...educed working period after charging indi cates that the battery pack is used and must be replaced Observe the notes for disposal Maintenance and Service Maintenance and Cleaning f Before any work on the measuring tool itself e g as sembling maintenance etc as well as when trans porting and storing remove the battery pack or the batteriesfromthemeasuringtool Dangerofinjurywhen accidentally actuati...

Page 11: ...Republic of China China Mainland Bosch Power Tools China Co Ltd 567 Bin Kang Road Bin Jiang District 310052 Hangzhou P R China Service Hotline 400 826 8484 Fax 86 571 8777 4502 E Mail contact ptcn cn bosch com www bosch pt com cn HK and Macau Special Administrative Regions Robert Bosch Hong Kong Co Ltd 21st Floor 625 King s Road North Point Hong Kong Customer Service Hotline 852 2101 0235 Fax 852 ...

Reviews: