English
|
21
Bosch Power Tools
1 609 929 X30 | (22.3.11)
Accessories
For more information on the complete quality accessories program,
please refer to the Internet under www.bosch-pt.com or contact your
specialist shop.
After-sales Service and Customer Assistance
Our after-sales service responds to your questions concerning mainte-
nance and repair of your product as well as spare parts. Exploded views
and information on spare parts can also be found under:
www.bosch-pt.com
Our customer service representatives can answer your questions con-
cerning possible applications and adjustment of products and accesso-
ries.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
Tel. Service: +44 (0844) 736 0109
Fax: +44 (0844) 736 0146
E-Mail: [email protected]
The nails are driven in too deep.
The rated pressure of the compressed-air supply is
too high.
– Reduce the compressed-air supply. 4 bar may not
be fallen below.
The depth stop is set too deep.
– Adjust the depth stop to the desired depth.
(See “Adjusting the Depth Stop”, page 18)
The buffer is worn.
– Contact an authorised service agent for Bosch
power tools.
Have the component replaced there.
The nails are not driven in deep enough. The rated pressure of the compressed-air supply is
too low.
– Increase the compressed-air supply. 8 bar may
not be exceeded.
The depth stop is set too high.
– Adjust the depth stop to the desired depth.
(See “Adjusting the Depth Stop”, page 18)
The length and diameter of supply-air hose
15
do not
correspond with the data of this pneumatic tool.
– Use a supply-air hose with the correct dimensions.
(See “Technical Data”, page 16)
The supply-air hose
15
is bent/creased.
– Correct the bend/crease in the supply-air hose.
The pneumatic tool skips nails or has a
too large cycle feed.
The fasteners being used are not permitted.
– Use only original accessories.
Only the fasteners (nails, staples, etc.) specified
in table “Technical Data” may be used.
The magazine
10
is not operating correctly.
– Clean and lubricate the magazine slider
11
as re-
quired and make sure that the magazine
10
is not
dirty/soiled.
The spring of the magazine slider is too week or de-
fective.
– Contact an authorised service agent for Bosch
power tools.
Have the component replaced there.
The sealing ring of the piston is worn or damaged.
– Contact an authorised service agent for Bosch
power tools.
Have the component replaced there.
Frequent jamming of nails in the shot
duct.
The fasteners being used are not permitted.
– Use only original accessories.
Only the fasteners (nails, staples, etc.) specified
in table “Technical Data” may be used.
– Contact an authorised service agent for Bosch
power tools.
The driven nails are bent.
The driver blade is damaged.
– Contact an authorised service agent for Bosch
power tools.
Have the component replaced there.
Contrary to working with normal operat-
ing speed, the nails are not driven in
deep enough at higher operating speed.
The interior diameter of the supply-air hose is too
low.
– Use a supply-air hose with the correct dimensions.
(See “Technical Data”, page 16)
The compressor is not suitable for fast operating
speeds.
– Use a compressor that is sufficiently dimensioned
for the number of connected pneumatic tools and
the operating speed.
Problem
Cause
Corrective Measure
OBJ_BUCH-1302-001.book Page 21 Tuesday, March 22, 2011 11:17 AM