![Bosch Greentherm T9800 SEO160 Installation And Operating Instructions Manual Download Page 15](http://html.mh-extra.com/html/bosch/greentherm-t9800-seo160/greentherm-t9800-seo160_installation-and-operating-instructions-manual_52825015.webp)
Installation instructions
15
Greentherm T9800 SEO 160/199 | SECO 199 – 6 720 817 281 (2018/12)
Fig. 5
Table 4
4.4
Mounting instructions
▶ The water heater is approved for installation directly on an
outside wall. Secure the wall mounting bracket provided
with the water heater to a wall surface. See fig. 6.
▶ The installation method of the mounting bracket will
depend on the type of mounting surface. Due to the
varieties of building siding or surfacing, the installer must
decide on how best to support and level the heater on an
outside wall. It is recommended that horizontal or vertical
support boards or plywood sheathing (½" minimum) first
be attached to the wall surface. The heater must be kept
level on the wall surface.
Fig. 6
Installation on wood siding
WARNING:
▶ Do not mount heater directly to vinyl siding. With vinyl
siding, a 3½' x 4' area of the siding must first be removed
and then replaced with wood or other non-plastic material.
See fig. 7.
Ref
.
Description
Min.
distances
A
Directly below or adjacent to an opening;
operable windows, doors and any fresh air
openings
1 ft
B
C
D
From any adjacent wall
1 ft
E
Below a gutter, sanitary pipework, eaves or
overhang
3 ft
F
Above ground
1 ft
G
From a gas meter or gas regulator
3 ft