Electrical connection
Gaz 6000 W – 6720866247 (2019/07)
20
6
Electrical connection
6.1
General notes
WARNING:
Risk to life from electric shock!
Touching live electrical parts can cause an electric shock.
▶ Before working on electrical parts, disconnect all phases of the
power supply (fuse/circuit breaker) and lock the isolator switch to
prevent unintentional reconnection.
▶ Safety measures according to national and international regulations.
▶ In rooms with a bath or a shower, connect the device to a circuit
breaker.
▶ Do not connect any additional consumers to the device power supply.
Fuses
The device is protected by two fuses. They are located on the circuit
board.
Replacement fuses are located on the cover of the control device.
6.2
Connect the device
Fig. 17 Protection zones
[1]
Safety zone 1, directly above the bath
[2]
Safety zone 2, within a radius of 60 cm from the bath/shower
If the cable is not long enough:
▶ Remove the main power cord and replace it with a suitable one
(
Table 16).
Connection outside safety zones 1 and 2:
▶ Attach a suitable mains plug to the mains cable.
▶ Insert plug into a grounded electrical socket.
-or-
▶ Securely connect the power cable to a manifold.
Connection inside safety zones 1 and 2:
▶ Remove the main power cord and replace it with a suitable cable
(
Table 16).
▶ Connect the main power cord in such a way that the ground
conductor is longer than the other conductors.
▶ Make the electrical connection via an isolator that disconnects all
phases with at least 3 mm contact separation (e.g. fuses, circuit
breakers).
▶ In safety zone 1: Route main power cord vertically upward.
The following cables are suitable as replacement for the built-in main
power cord:
Table 16 Suitable main power cord
Connecting area
Suitable cable
Inside safety zones 1 and 2
NYM-I 3 × 1.5 mm
2
Outside safety zones 1 and 2
HO5VV-F 3 × 1.0 mm
2
HO5VV-F 3 × 0.75 mm
2
225 cm
6 720 612 659-13.3TT
2
2
1
1
60 cm
60 cm
Summary of Contents for Gaz 6000 W
Page 50: ......
Page 51: ......
Page 52: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...