24
| English
1 609 92A 0XF | (30.9.14)
Bosch Power Tools
Removing/Replacing the Flat-fold Filter
(see figures J1–J2)
Replace a damaged flat-fold filter
30
immediately.
– Pull the locking latch
20
and open the filter cover
39
.
– Grasp the flat-fold filter
30
by the fins, pull up and remove.
– When taking out the flat-fold filter
30
, remove any accumu-
lating dust and debris from the closing edge of the filter
cover
39
using a moist cloth.
PES and PTFE flat-fold filters can be flushed out under run-
ning water.
– Insert a new or the cleaned flat-fold filter
30
; observe prop-
er and tight seating.
– Shut the filter cover
39
again (must be heard to engage).
Container
Wipe out the container
1
from time to time with a commercial-
ly available, non-scouring cleaning agent and allow to dry.
Level Sensors (see figure K)
Clean the level sensors
40
occasionally.
– Unlock the latches
15
and remove the vacuum lid
13
.
– Clean the level sensors
40
with a soft cloth.
– Reattach the vacuum lid
13
again and lock the latches
15
.
Storage (see figure L)
– Wind the mains cable around the cable holder
14
.
– Insert the accessories into the holders provided: Vacuum
tubes
35
in holders
22
, crevice nozzle
31
in holder
21
,
floor nozzle
34
in holder
24
.
– Undue the elastic tie-downs of the vacuum-hose holders
4
and place the vacuum hose
27
around the vacuum cleaner
lid into the holders
4
.
Reattach the elastic tie-downs.
– Mount the L-Boxx onto the retainers
11
.
– For transport of the vacuum cleaner, screw the plug cap
2
onto the hose connection piece
3
.
– Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
– To lock the castors
18
, actuate the castor brakes
17
by
pushing down.
Transport (see figure M)
– Carry the vacuum cleaner only by the carrying handle
10
.
– Use the push handle
12
for moving the VAC around or pull-
ing it over edges or obstacles.
Correction of Malfunctions
Problem
Corrective Measure
The vacuum turbine does not start.
– Check mains cable, mains plug, fuse, socket outlet and filling-level sensors
40
.
Mode selector switch
7
set to “Start/Stop automatic”.
– Set mode selector switch
7
to the “vacuum” symbol and switch the power
tool connected to the socket outlet
5
on.
Vacuum turbine switches off.
– Empty container
1
.
Vacuum turbine does not restart after emptying
the container.
– Switch vacuum cleaner off and wait 5 seconds; switch on again after 5 sec-
onds.
– Clean level indicators
40
as well as the space between the level indicators
40
with a brush.
Vacuuming power decreases.
– Remove clogs from vacuum nozzle, vacuum tubes
35
, vacuum hose
27
or
flat-fold filter
30
.
– Replace disposal bag
29
or dust bag.
– Engage filter cover
39
properly.
– Mount vacuum cleaner lid
13
properly and lock latches
15
.
– Replace flat-fold filter
30
.
Dust escapes during vacuuming
– Check proper installation of the flat-fold filter
30
.
– Replace flat-fold filter
30
.
The automatic shut-off (wet vacuuming) does
not respond.
– Clean level indicators
40
as well as the space between the level indicators
40
with a brush.
The automatic shut-off does not function with non-conductive liquids or
foam/bubbles.
– Monitor the level continuously.
OBJ_BUCH-1747-003.book Page 24 Tuesday, September 30, 2014 10:13 AM