–
To connect a monitor for set-up, use the optional 3 m cable
(NBN-MCSMB-30M) to connect directly to the CVBS
connector of a monitor.
–
For a permanent analog output, use the optional 0.3 m
cable (NBN-MCSMB-03M) to connect to a high quality coax
cable.
Mounting the camera module
Mounting flush to ceiling
To mount the camera flush to the ceiling:
1.
Mark out the recess hole and the three mounting holes. The
mounting holes are equally spaced around a diameter of
133 mm (5.25 in).
2.
Cut out the inner recess hole: Ø105 mm (4.13 in).
3.
Use a 8 mm (0.31 in) bit to drill the three mounting holes
4.
Insert the supplied mounting plugs (8 x 40) into the
mounting holes.
5.
Use the supplied screws (DIN7505-B 50mm) to securely
mount the camera to the ceiling surface; if the ceiling is too
thin, use appropriate ceiling bolts (not supplied).
57.6 (2.27)
57.6 (2.27)
33.3 (1.31)
66.5 (2.62)
Ø
133 (
Ø
5.25)
mm (in)
4S box
(x2)
5.4
5.4.1
FLEXIDOME IP starlight
7000 VR
Installation | en
17
Bosch Security Systems
2016.06 | v1.0 | AM18-Q0710
Summary of Contents for FLEXIDOME IP starlight 7000 VR
Page 1: ...FLEXIDOME IP starlight 7000 VR NIN 73013 NIN 73023 en Installation Manual ...
Page 2: ......
Page 38: ......
Page 39: ......