Bosch EV300 Operator'S Manual Download Page 16

 SP01502138

Ver.00

© Bosch Automotive Service Solutions Inc.

3. 

Utilisez quatre vis d’expansion incluses et 
quatre vis M6 pour fixer le support d’installation 
mural au mur (voir l’illustration 5).

Ill. 5 : 

Support d’installation mural

6.2.2 

Installation sur un mur en bois

1. 

En utilisant le support d’installation mural, 
mesurez et marquez l’espacement d’installation 
nécessaire pour assurer un positionnement 
adéquat et de niveau.

2. 

Utilisez quatre vis autotaraudeuses M6 incluses 
pour fixer le support d’installation mural au 
mur (voir l’illustration 6).

Ill. 6 : 

Support d’installation mural

6.3 

Station de recharge

1. 

Fixez l’unité d’alimentation CA EV 300 au 
support d’installation mural en accrochant 
l’encoche arrière supérieure à l’onglet 
supérieur du support d’installation mural (voir 
l’illustration 7).

Ill. 7 : 

Alignement de l’EV 300 sur le support mural

5.  Outils recommandés

Outil

Description

Tournevis cruciforme

No 2

Voltmètre/multimètre numérique
Niveau

Outil pour écrire

Crayon, stylo ou 

marqueur

Perceuse électrique
Foret pour le béton

6.  Installation

Les sections suivantes fournissent les informations 
requises pour commencer à utiliser l’EV 300, incluant 
les instructions d’installation du support mural.

6.1 

Spécifications

 

$

La structure de support doit pouvoir 
supporter une charge de 36 kg (79,4 lb).

 

$

L’espace doit être fermé et bien aéré.

 

$

Un disjoncteur à 40 A de type B, C ou D doit 
être installé dans le circuit précédent la boîte 
de distribution CA.

 

$

Un sectionneur pour chaque conducteur 
non mis à la terre d’entrée CA est requis, 
conformément au Code national de 
l’électricité, ANSI/NFPA 70.

 

$

Un dégagement vertical de 1,2 m (4 pi) à 
partir de la surface d’utilisation.

 

$

Un dégagement de 250 mm (10 po) des côtés 
gauche et droit.

 

$

L’installation doit être effectuée du même côté 
que l’entrée de recharge du véhicule.

6.2 

Support d’installation mural

.

6.2.1 

Installation sur un mur en béton

1. 

En utilisant le support d’installation mural, 
mesurez et marquez l’espacement d’installation 
nécessaire pour assurer un positionnement 
adéquat et de niveau.

2. 

À l’aide d’un foret à béton de 8 mm, percez des 
trous correspondants aux trous sur le support 
d’installation mural (voir l’illustration 4).

100

80

17

4

Ø7x4

Ill. 4 : 

Espacement des trous du support 

d’installation mural

16  |  EV 300  |  Outils recommandés

fr

Summary of Contents for EV300

Page 1: ...EV300 7 6kW AC Charger en Operators Manual Electric vehicle battery charger fr Guide d utilisation Chargeur de batterie de véhicule électrique ...

Page 2: ...SP01502138 Ver 00 Bosch Automotive Service Solutions Inc Contents en Content English 3 fr Contenu en français 12 2 EV 300 ...

Page 3: ... Scope of Delivery 5 4 3 EV 300 Status Indicator LEDs 5 5 Recommended Tools 6 6 Installation 6 6 1 Requirements 6 6 2 Wall mounting Bracket 6 6 2 1 Mounting on Concrete 6 6 2 2 Mounting on Wood 6 6 3 Charging Unit 6 6 4 Receptacle Requirements 7 7 Operation 7 7 1 Initial Power On 7 7 2 Charging Sequence 7 8 General Maintenance 7 8 1 Daily Maintenance 7 9 Decommissioning 7 9 1 Temporary Shutdown 7 ...

Page 4: ...gs warn of dangers to the user or people in the vicinity Warning notices also indicate the consequences of the danger as well as preventive action Warnings have the following structure Warning symbol SIGNAL WORD nature and source of danger Consequences of the danger in the event of failure to take action and observe notices given Actions and instructions to pre vent the danger The signal word indi...

Page 5: ...rs cracked frayed broken or damaged R Do not attempt to open disassemble repair tamper with or modify the EV 300 Contact our Customer Service for any required repairs R Do not use the EV 300 when the user the vehicle or the charger is exposed to severe rain snow or other severe weather R When transporting the EV 300 handle with care R Do not touch the charging connector terminal with metallic obje...

Page 6: ...rotection provided by the EV 300 and the supplied accessories may be compromised 4 2 Scope of Delivery The EV 300 includes the AC charging unit charging connector and wall mounting bracket 1 2 3 5 4 6 Item Kit Component Part number Qty 1 AC Charger 1 699 200 338 1 2 Wall Mounting Bracket 1 699 200 366 1 3 User Manual SP01502138 1 4 Expansion Screw 4 5 M4 Screw 2 6 M6 Self Tapping Screws 4 4 3 EV 3...

Page 7: ... or marker Powered drill Drill bit for concrete 6 Installation The following sections provide the information needed to begin using the EV 300 including installing the wall mounting bracket 6 1 Requirements Supporting structure must be able to withstand a 36 kg 79 4 lb load Enclosed and well ventilated space Type B C or D 40 Amp breaker installed in upstream AC distribution box Disconnect switch f...

Page 8: ... status light will remain lit 7 2 Charging Sequence 1 Plug charging cable into vehicle charging inlet The blue LED flashes to indicate charging in process shown in Fig 2 When charging has finished the blue LED will stop flashing and remain lit 2 Remove charging connector from EV when charging is complete 8 General Maintenance i The EV 300 does not contain any user ser viceable parts Do not open th...

Page 9: ...will be free from defects in materials and workmanship for a period of three years from the date of purchase War ranty Period This warranty is valid for pur chasers located in the U S A and Canada only ALL WARRANTY CLAIMS MUST BE MADE WITH IN THE WARRANTY PERIOD AND PROOF OF PURCHASE ACCEPT ABLE TO BOSCH MUST BE SUPPLIED 9 2 Changing Location If the EV 300 is handed over to someone else hand over ...

Page 10: ...per maintenance and care mod ification disassembly operation outside of the Charging Station specifications or in a manner inconsistent with instructions regarding use This warranty does not apply if the Charging Station s original identification markings for example serial numbers and trademarks have been defaced altered or removed The Charging Station is not certified for plugin applications and...

Page 11: ...D SP D Ground Fault Protection Output Protection OCP OTP Control Pilot Fault Pro tection Output Interface SAE J1772 AC Charging Con nector Mechanical properties Size 280 x 260 x 100 mm 11 x 10 25 x 4 in Weight 4 0 5 kg 8 8 lb Cable Length 5M 16 4 ft Operating Temperature 30 C 50 C 22 F 122 F Storage Temperature 40 C 70 C 40 F 158 F Relative Operation Humidity 95 RH Maximum Maximum operating altitu...

Page 12: ... état à DEL 14 5 Outils recommandés 15 6 Installation 15 6 1 Spécifications 15 6 2 Support d installation mural 15 6 2 1 Installation sur un mur en béton 15 6 2 2 Installation sur un mur en bois 15 6 3 Station de recharge 15 6 4 Spécifications de la prise électrique 16 7 Fonctionnement 16 7 1 Alimentation initiale 16 7 2 Séquence de chargement 16 8 Entretien général 16 8 1 Entretien quotidien 16 9...

Page 13: ...es à proximité Ils indiquent aussi les conséquences du danger et les actions préventives Les avertissements présentent la structure suivante Symbole d avertis sement MOT INDICATEUR Nature et source du danger Conséquence du danger dans l éventualité où les bonnes actions ne sont pas suivies et les remarques observées Actions et instructions pour prévenir le danger Le mot indicateur spécifie la prob...

Page 14: ...démonter de réparer ou de trafiquer l EV 300 Communiquez avec notre service à la clientèle pour toute réparation R N utilisez pas l EV 300 lorsque l utilisateur le véhicule ou le chargeur est exposé à une pluie ou une neige intense ou en cas de tout autre condition météorologique extrême R Transportez toujours avec soin l EV 300 R Ne touchez pas les bornes du connecteur de recharge avec des objets...

Page 15: ...EV 300 et les accessoires fournis pourrait ne pas s appliquer 4 2 Ensemble livré L EV 300 comprend une unité de recharge CA un connecteur de recharge et un support d installation mural 1 2 3 5 4 6 Article Composants de la trousse Numéro de pièce Qté 1 Chargeur CA 1 699 200 338 1 2 Support d installation mural 1 699 200 366 1 3 Guide d utilisation SP01502138 1 4 Vis d expansion 4 5 Vis M4 2 6 Vis a...

Page 16: ...allation Les sections suivantes fournissent les informations requises pour commencer à utiliser l EV 300 incluant les instructions d installation du support mural 6 1 Spécifications La structure de support doit pouvoir supporter une charge de 36 kg 79 4 lb L espace doit être fermé et bien aéré Un disjoncteur à 40 A de type B C ou D doit être installé dans le circuit précédent la boîte de distribut...

Page 17: ...te allumé 7 2 Séquence de chargement 1 Branchez le câble de recharge à l entrée de recharge du véhicule La DEL bleue clignote pour indiquer que la recharge est en cours indiqué dans l illustration 2 Une fois la recharge terminée la DEL bleue arrête de clignoter et reste allumée 2 Retirez le connecteur de recharge du véhicule électrique lorsque la recharge est terminée 8 Entretien général i L EV 30...

Page 18: ...tenir de l assistance Bosch Automotive service Solutions Inc Bosch garantit à l acheteur que la station de recharge sera exempte de défauts de matériaux et de fabrication pour une période de trois ans à compter de la date d achat période de garantie Cette garantie est valable uniquement pour les acheteurs aux États Unis et au Canada 9 2 Changement d emplacement Si l EV 300 est remis à une autre pe...

Page 19: ...igence un mauvais entretien et soin une modification un démontage un fonctionnement en dehors des spécifications de la station de charge ou d une manière incompatible avec les instructions relatives à l utilisation Cette garantie ne s applique pas si les étiquettes d identification d origine de la station de charge par exemple les numéros de série et les marques de commerce ont été altérées ou enl...

Page 20: ...ntre les fuites à la terre Protection de la sortie OCP OTP protection contre les défaillances du pilote de contrôle Interface de sortie Connecteur de recharge CA SAE J1772 Propriétés mécaniques Taille 280 x 260 x 100 mm 11 x 10 25 x 4 po Poids 4 0 5 kg 8 8 lb Longueur du câble 5 m 16 4 pi Température de fonctionnement 30 C 50 C 22 F 122 F Température d entreposage 40 C 70 C 40 F 158 F Humidité rel...

Page 21: ...Bosch Automotive Service Solutions Inc 28635 Mound Road Warren Michigan 48092 USA https www boschautomotiveservicesolutions com SP0 150 2138 Ver 00 09 December 2021 ...

Reviews: