background image

en 

Installation instructions

12

WARNING ‒ Risk of electric shock!

Sharp-edged components inside the appli-

ance may damage the connecting cable.

Do not kink or trap the connecting cable.

Incorrect installation is dangerous.

Connect and operate the appliance only in

accordance with the specifications on the

rating plate.

Connect the appliance to a power supply

with alternating current only via a properly

installed socket with earthing.

The protective conductor system of the do-

mestic electrical installation must be prop-

erly installed.

Never equip the appliance with an external

switching device, e.g. a timer or remote

control.

When the appliance is installed, the mains

plug of the power cord must be freely ac-

cessible. If free access is not possible, an

all-pole isolating switch must be installed in

the permanent electrical installation accord-

ing to the conditions of Overvoltage Cat-

egory III and according to the installation

regulations.

When installing the appliance, check that

the power cable is not trapped or dam-

aged.

12.5 General information

Follow these general instructions during the installation.

¡

For the installation, observe the currently valid build-

ing regulations and the regulations of the local elec-

tricity and gas suppliers.

¡

When discharging the exhaust air, the official and

legal regulations, such as the regional building

code., must be observed.

¡

In order to freely access the appliance for servicing,

select an easy-to-reach installation site.

¡

The surfaces of the appliance are sensitive. Avoid

damaging them during installation.

12.6 Instructions for the electrical

connection

In order to safely connect the appliance to the elec-

trical system, follow these instructions.

WARNING ‒ Risk of electric shock!

It must always be possible to disconnect the appliance

from the electricity supply. The appliance must only be

connected to a protective contact socket that has been

correctly installed.

The mains plug for the mains power cable must be

easily accessible after the appliance is installed.

If this is not possible, an all-pole isolating switch

must be integrated into the permanent electrical in-

stallation according to the conditions of overvoltage

category III and according to the installation regula-

tions.

The permanent electrical installation must only be

wired by a professional electrician. We recommend

installing a residual-current circuit breaker (RCCB)

in the appliance's power supply circuit.

Sharp-edged components inside the appliance may

damage the connecting cable.

Do not kink or trap the connecting cable.

¡

The connection data can be found on the rating

plate. → 

Page 9

¡

The connecting cable is approx. 1.30 m long.

¡

This appliance complies with the EC interference

suppression regulations.

¡

The appliance corresponds to protection class 1.

You should therefore only use the appliance with a

protective earth connection.

¡

Do not connect the appliance to the power supply

during installation.

¡

Ensure that the protection against contact is guaran-

teed during installation.

12.7 Information on the installation situation

¡

Install this appliance on the kitchen wall.

¡

To install additional special accessory parts, ob-

serve the enclosed installation instructions.

¡

The appliance must be installed with no more than

one side directly next to a high-sided unit or a wall.

The distance between the appliance and wall or

high-sided unit must be at least 50 mm.

¡

The width of the extractor hood must correspond at

least with the width of the hob.

¡

To optimally detect the cooking vapours, install the

appliance in the middle of the hob.

12.8 Instructions for the exhaust air pipe

The appliance manufacturer does not provide any war-

ranty for faults attributable to the pipeline.

¡

Use a short, straight exhaust air pipe with as large a

pipe diameter as possible.

¡

Long, rough exhaust air pipes, many pipe bends or

small pipe diameters reduce the suction power and

increase the fan noise.

¡

Use an exhaust pipe that is made of non-combust-

ible material.

¡

To prevent condensate from returning, fit the ex-

haust pipe with a 1° gradient from the appliance.

Flat ducts

Use flat ducts with an inner cross-section that corres-

ponds to the diameter of the round pipes:

¡

Diameter of 150 mm corresponds to ap-

prox. 177 cm².

¡

Diameter of 120 mm corresponds to ap-

prox. 113 cm².

¡

Use sealing strips for different pipe diameters.

¡

Do not use any flat ducts with sharp bends.

Round pipes

Use round pipes with an inner diameter of 150 mm (re-

commended) or at least 120 mm.

Summary of Contents for DWK 6AJ 0 Series

Page 1: ...Register your new device on MyBosch now and get free benefits bosch home com welcome Extractor hood DWK 6AJ 0 DWK 6AJ69M DWK96AJ69M en User manual and installation instructions ...

Page 2: ... and by people who have reduced physical sensory or mental abilities or inad equate experience and or knowledge provided that they are supervised or have been instructed on how to use the appliance safely and have understood the resulting dangers Do not let children play with the appliance Children must not perform cleaning or user maintenance unless they are at least 15 years old and are being su...

Page 3: ...er Switch off the cooking zone Extinguish flames carefully using a lid fire blanket or something similar When gas burners are in operation without any cookware placed on them they can build up a lot of heat A ventilation appliance in stalled above the cooker may become dam aged or catch fire Only operate the gas burners with cook ware on them Operating multiple gas hobs at the same time generates ...

Page 4: ...nstalled with a gradient of at least 1 from the appliance If you put incorrect stress on the design elements they may break off Do not pull design elements Do not place objects on the design elements or hang objects from them There is a risk of surface damage if you do not peel off the protective film Remove the protective film from all parts of the ap pliance before using for the first time If on...

Page 5: ...erating the appli ance in circulating air mode can be found in our catalogue Alternatively ask your dealer The required accessor ies are available from specialist retail ers from customer service or from the Online Shop 5 Familiarising yourself with your appliance 5 1 Controls The controls are used to configure all functions of your appliance and to obtain information about the operat ing status S...

Page 6: ...um parts in the interior of the appliance may cause explosions Never use highly caustic alkaline or highly acidic cleaning agents In particular do not use commer cial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switc...

Page 7: ...rs may catch fire Clean the grease filters regularly ATTENTION The grease filters may become damaged if they are squeezed Do not squeeze the grease filters Note When cleaning the grease filter in the dish washer light discolouration may occur This discoloura tion has no effect on the performance of the metal grease filters Requirement The grease filters have been removed Removing the grease filter...

Page 8: ...er cord is not plugged in Connect the appliance to the power supply The circuit breaker is faulty Check the circuit breaker in the fuse box There has been a power cut Check whether the lighting in your kitchen or other appliances are working The LED lighting does not work The LED lamp is defective Replacing the LED lights Page 8 9 2 Replacing the LED lights WARNING Risk of electric shock When chan...

Page 9: ...throughout the EU 11 Customer Service If you have any queries on use are unable to rectify faults on the appliance yourself or if your appliance needs to be repaired contact Customer Service Detailed information on the warranty period and terms of warranty in your country is available from our after sales service your retailer or on our website If you contact Customer Service you will require the ...

Page 10: ... installed and dis charge the exhaust gases into the open through an exhaust gas system e g a chim ney With the extractor hood switched on air is extracted from the kitchen and the adjacent rooms Without an adequate supply of air the air pressure falls below atmospheric pressure Toxic gases from the flue or the extraction shaft are sucked back into the living space Always ensure adequate fresh air...

Page 11: ...e the larger of the two must al ways be provided for If gas hobs and elec tric hobs are operated together the largest specified clearance applies The appliance must be installed with no more than one side directly next to a high sided unit or a wall The distance between the appliance and wall or high sided unit must be at least 50 mm Grease deposits in the grease filter may catch fire Never work w...

Page 12: ...tallation according to the conditions of overvoltage category III and according to the installation regula tions The permanent electrical installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Sharp edged components inside the appliance may damage the connecting cable Do not kink or trap ...

Page 13: ... enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks Preparing the wall 1 Ensure that there are no electrical wires gas pipes or water pipes in the area where holes are to be drilled 2 Cover the hob to prevent damage 3 Mark a vertical centre line on the wall from the ceil ing to the low...

Page 14: ... the electrical connection Page 12 Fitting the flue duct WARNING Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Remove the protective foil from both flue duct sec tions 2 Fit the upper flue duct section Gently push the two side panels apart and then hook them into the angle bracket on the left and right Screw the upper flue duct section onto the sides ...

Page 15: ......

Page 16: ...ooking for help You ll find it here Expert advice for your Bosch home appliances help with problems or a repair from Bosch experts Find out everything about the many ways Bosch can support you www bosch home com service Contact data of all countries are listed in the attached service directory 9001703059 9001703059 011130 en Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY ww...