en
Installation instructions
12
The appliance is heavy.
▶
The appliance must not be fitted directly
onto plasterboard or similar lightweight ma-
terials.
▶
To ensure correct installation, you must use
a material which is sufficiently stable and
suitable for both the structural conditions
and the weight of the appliance.
Changes to the electrical or mechanical as-
sembly are dangerous and may lead to mal-
functions.
▶
Do not make any changes to the electrical
or mechanical assembly.
The filter cover may swing out.
▶
Open the filter cover slowly.
▶
Take hold of the filter cover after opening
until it no longer swings out.
▶
Close the filter cover slowly.
Risk of injury when opening and closing the
hinges.
▶
Keep your hands away from the hinges.
WARNING ‒ Risk of electric shock!
Sharp-edged components inside the appli-
ance may damage the connecting cable.
▶
Do not kink or trap the connecting cable.
If the appliance or the power cord is dam-
aged, this is dangerous.
▶
Never operate a damaged appliance.
▶
Never pull on the power cord to unplug the
appliance. Always unplug the appliance at
the mains.
▶
If the appliance or the power cord is dam-
aged, immediately unplug the power cord
or switch off the fuse in the fuse box.
▶
Incorrect repairs are dangerous.
▶
Repairs to the appliance should only be
carried out by trained specialist staff.
▶
Only use genuine spare parts when repair-
ing the appliance.
▶
If the power cord of this appliance is dam-
aged, it must be replaced by trained spe-
cialist staff.
Incorrect installation is dangerous.
▶
Connect and operate the appliance only in
accordance with the specifications on the
rating plate.
▶
Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.
▶
The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.
▶
Never equip the appliance with an external
switching device, e.g. a timer or remote
control.
▶
When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.
▶
When installing the appliance, check that
the power cable is not trapped or dam-
aged.
12.5 Instructions for the electrical
connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
WARNING ‒ Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
▶
The mains plug for the mains power cable must be
easily accessible after the appliance is installed.
▶
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
▶
The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
▶
Do not kink or trap the connecting cable.
¡
The connection data can be found on the rating
plate. →
¡
The connecting cable is approx. 1.30 m long.
¡
This appliance complies with the EC interference
suppression regulations.
¡
The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.
¡
Do not connect the appliance to the power supply
during installation.
Summary of Contents for DWJ67HM60
Page 15: ......