background image

Imp

ort

Ap

plia

nce

s.c

om

THE EASIEST WAY TO SELF-IMPORT APPLIANCES DIRECT FROM EUROPE.

  Cleaning and maintenance   

en

7

Lighting

The lighting can be switched on and off independently 

of the fan.
Touch the 

B

 symbol.

Setting the brightness

Press and hold the 

B

 symbol until the required 

brightness is reached.

Saturation display

If the metal grease filters or activated charcoal filter are/

is saturated, the corresponding symbols flash once the 

appliance has been switched off:

Metal grease filter: 

E

Activated charcoal filter: 

F

Metal grease filter and activated charcoal filter: 

 

E

 

and 

F

If you have not yet done so, the metal grease filters 

should now be cleaned or the activated charcoal filter 

replaced. 

~

 "Cleaning and maintenance" on page 7

The saturation displays can be reset  while they are 

flashing. To do this, touch the 

E

 or 

F

 symbol.

Switching over the display for the air circulation 

mode

For air recirculation mode, the electronic controller must 

be switched over accordingly:

The extractor hood must be connected and switched 

off.

Touch and hold the 

:

 symbol. Use the rotary 

selector to change the display to 2. Take your finger 

off the 

:

 symbol. This switches the electronic 

controller over to air recirculation mode (filters that 

cannot be regenerated).

Touch and hold the 

:

 symbol. Use the rotary 

selector to change the display to 3. Take your finger 

off the 

:

 symbol. This switches the electronic 

controller over to air recirculation mode (filters that 

can be regenerated).

Repeatedly touching and holding the 

:

 symbol and 

changing the display to "1" switches the electronic 

controller back to air extraction mode.

Audible signal 

Switching on

Touch and hold the 

#

 and 

y

 symbols at the same 

time for approximately three seconds when the fan is 

switched off. As confirmation, an audible signal sounds 

and 

 is shown in the display.

Switching off

Touch and hold the 

#

 and 

y

 symbols at the same 

time for approximately three seconds when the fan is 

switched off. As confirmation, 

 is shown in the display.

2

Cleaning and maintenance

Cleaning and maintenance

:

Warning

Risk of burns!

The appliance becomes hot during operation. Allow the 

appliance to cool down before cleaning.

:

Warning

Risk of electric shock!

Penetrating moisture may result in an electric shock. 

Clean the appliance using a damp cloth only. Before 

cleaning, pull out the mains plug or switch off the circuit 

breaker in the fuse box.

:

Warning

Risk of electric shock!

Do not use any high-pressure cleaners or steam 

cleaners, which can result in an electric shock.

:

Warning

Risk of injury!

Components inside the appliance may have sharp 

edges. Wear protective gloves.

:

Warning

Risk of injury!

Risk of trapping body parts when opening and closing 

the glass front. Do not reach into the area behind the 

glass panel, and keep your fingers away from the 

hinges.

Cleaning agents

To ensure that the different surfaces are not damaged 

by using the wrong cleaning product, follow the 

instructions in the table. Do not use any of the following:

Harsh or abrasive cleaning agents, e.g. scouring 

powder or liquid scouring cleaner,

Cleaning products with a high alcohol content,

Hard scouring pads or cleaning sponges,

Pressure washers or steam cleaners,

Cleaning products that dissolve limescale,

Aggressive all-purpose cleaning products,

Oven spray.

Note: 

Wash new sponge cloths thoroughly before use.

Note: 

Follow all instructions and warnings included with 

the cleaning products.

Summary of Contents for DWF97RU60

Page 1: ...OM EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or questions please contact us via email info ImportAppliances com User Manual ...

Page 2: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE en Instructions for installation and use Extractor hood ...

Page 3: ...cation This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used ...

Page 4: ...mbustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is opera...

Page 5: ...ective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while cooking to avoid condensation Condensate can produce corrosion d...

Page 6: ...vironmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsi...

Page 7: ...the extractor hood automatically switches back to fan setting 3 Switching off If you want to end the intensive mode before the set time has elapsed turn the rotary selector anti clockwise Intermediate position for the glass front On some appliances the glass front can be adjusted to an intermediate position The intermediate position can be used for eliminating particularly strong cooking smells an...

Page 8: ...tion mode Audible signal Switching on Touch and hold the and y symbols at the same time for approximately three seconds when the fan is switched off As confirmation an audible signal sounds and is shown in the display Switching off Touch and hold the and y symbols at the same time for approximately three seconds when the fan is switched off As confirmation is shown in the display 2Cleaning and mai...

Page 9: ...oak the metal grease filters in hot soapy water Clean the filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing...

Page 10: ...only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only ...

Page 11: ...ote Observe the installation instructions in the accessory E no FD no After sales serviceO GB 0344 892 8979 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute Z Nr FD E Nr Type Accessories Order number Starter set for air recirculation mode flat hood with chimney Easy change filter for starter set DWZ0AF0U0 DWZ0AF0A0 Starter set for air recircula...

Page 12: ...ct must be fitted If the extractor hood is to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them duri...

Page 13: ...ler is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers...

Page 14: ...operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Swee...

Page 15: ...w children to play with packaging material KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboa...

Page 16: ...lation mode 1 Determine where the extractor hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety cleara...

Page 17: ...n 16 Fitting with a flue duct Fitting without a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Page 18: ...ctor 3 Use suitable means to seal both joints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the a...

Page 19: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 6 ...

Page 20: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 6 ...

Page 21: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 970824 9001159540 9001159540 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Reviews: