Summary of Contents for DWB98JQ50

Page 1: ...OM EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or questions please contact us via email info ImportAppliances com User Manual ...

Page 2: ...com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 3FHJTUFS RXU QHZ GHYLFH RQ 0 RVFK QRZ DQG JHW IUHH EHQHILWV CPTDI IPNF DPN XFMDPNF en Instructions for installation and use Extractor hood Extractor hood ...

Page 3: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE ...

Page 4: ...ance works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres ...

Page 5: ... cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode War...

Page 6: ...after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Causes of damage Caution Risk of damage due to corros...

Page 7: ...disposal Dispose of packaging in an environmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the co...

Page 8: ...e the intensive setting if there is a large build up of odours and fumes vapours Switching on Touch the C or D symbol Note After approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you want to end intensive mode before the preset time expires touch the symbol for the required fan setting Fan run on time Switching on Touch the y symbol The fan will run ...

Page 9: ... over the display for air recirculation mode For air recirculation mode the electronic controller must be switched over accordingly The extractor hood must be connected and switched off Touch and hold the D symbol Touch the 2 symbol Take your finger off the D symbol This will switch the electronic controller over to air recirculation mode filters that cannot be regenerated Touch and hold the D sym...

Page 10: ...um fan setting is set automatically using the PerfectAir sensor Switching off Touch or any fan setting to switch off automatic mode The fan switches itself off automatically if the PerfectAir sensor detects no further change in the air quality in the room Automatic mode can run for a maximum of 4 hours Sensor control In automatic mode the PerfectAir sensor in the extractor hood detects the intensi...

Page 11: ...e D symbol and touching the 1 symbol switches the electronic controller back over to air extraction mode Audible signal Switching on Touch and hold the and y symbols at the same time for approximately 3 seconds when the fan is switched off An audible signal will sound as an acknowledgement Switching off Touch and hold the and y symbols at the same time for approximately 3 seconds when the fan is s...

Page 12: ...he filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease fi...

Page 13: ...only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only ...

Page 14: ...ese instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO GB 0344 892 8979 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute Accessory narrow 260 mm Order number Start...

Page 15: ...r is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers W...

Page 16: ...air must therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors w...

Page 17: ...e an all pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Risk o...

Page 18: ...p deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete p...

Page 19: ...g to the lower edge of the extractor hood 2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for fastening the appliance and press in the wall plugs flush with the wall Installation 1 Screw on the fixing bracket for the flue duct 2 Screw on brackets for the extractor hood hand tight Do not fir...

Page 20: ...ttach the exhaust air pipe directly to the air pipe connector and seal Exhaust air pipe Ø 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately Attaching the flue duct Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Separate the flue duct...

Page 21: ...ODF EBUB BU IBOE t BTZ BDDFTT UP PTDI PNF QQMJBODFT 4FSWJDF UHH DQG HDV UHJLVWUDWLRQ DOVR RQ PRELOH SKRQHV XXX CPTDI IPNF DPN XFMDPNF PPLJOH GPS IFMQ PV MM GJOE JU IFSF SHUW DGYLFH IRU RXU RVFK KRPH DSSOLDQFHV QHHG KHOS ZLWK SUREOHPV RU D UHSDLU IURP RVFK H SHUWV LQG RXW HYHU WKLQJ DERXW WKH PDQ ZD V RVFK FDQ VXSSRUW RX XXX CPTDI IPNF DPN TFSWJDF POUBDU EBUB PG BMM DPVOUSJFT BSF MJTUFE JO UIF BUUB...