background image

General information    

en

13

K

General information

General information

Checking the wall

The wall must be level, vertical and adequately load-

bearing.

The depth of the bore holes must be the same 

length as the screws. The wall plugs must have a 

secure grip.

The enclosed screws and wall plugs are suitable for 

solid brickwork. Suitable fasteners must be used for 

other structures (e.g. plasterboard, porous concrete, 

poroton bricks).

The maximum weight of the extractor hood is 

40 kg

.

Electrical connection

:

Warning – Risk of electric shock! 

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

The required connection information can be found on 

the rating plate on the top of the appliance.

Length of the cable: approx. 1.30 m

This appliance complies with the EC interference 

suppression regulations.

:

Warning – Risk of electric shock! 

It must always be possible to disconnect the appliance 

from the power supply. The appliance must only be 

connected to a protective contact socket that has been 

correctly installed. If the plug can no longer be reached 

after installation, an energy-isolating device in the 

phases must be provided in the permanent electrical 

installation in accordance with the installation 

regulations. The permanent electrical installation must 

only be wired by a professional electrician. We 

recommend installing a residual-current circuit breaker 

(RCCB) in the appliance's power supply circuit.

5

Installation

Installation

Preparing the installation

Caution!

Ensure that there are no electric wires, gas or water 

pipes in the area where holes are to be made.

Caution!

Holes must be drilled differently depending on how the 

appliance is designed. Before installing the extractor 

hood, take note of its design.

1.

Mark a vertical centre line on the wall from the 

ceiling to the lower edge of the extractor hood.

2.

Mark positions for the screws and the contour of the 

attachment area.

3.

Drill 8mm Ø holes to a depth of 80mm and press 

the wall plugs flush with the wall.

 ¨

4.

Screw on the fixing bracket for the flue duct.

 ©

5.

Screw in 2 securing screws with washers to 

approx.5mm.

 ª

[

!

!

$

%

&

Summary of Contents for DWA64BC50B

Page 1: ... en Instructions for installation and use Extractor hood ...

Page 2: ...n This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by ch...

Page 3: ...In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the grease filter may catch fire Regularly clean the grease filter Neve...

Page 4: ...ny high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while cooking to avoid condensation Condensate can produce corrosion damage Always replace faulty bulbs to prevent the remaining bulbs from overloading Risk of damage due to ingress of humidity into the electronic circuitry Never ...

Page 5: ...modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed throug...

Page 6: ... appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Warning Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves Caution There is a risk of surface damage if you do...

Page 7: ...em thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Place the me...

Page 8: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only Warning Risk of injury The light emitted ...

Page 9: ...sionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Accessories not included in the scope of delivery Note These instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installatio...

Page 10: ...en Installation instructions 10 INSTALLATION INSTRUCTIONS Installation instructions Installationinstructions PLQ PLQ PLQ PLQ PLQ PLQ PLQ PLQ ...

Page 11: ...e being operated together the largest specified clearance applies Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There must be no flying sparks When conveying the exhaust air...

Page 12: ...stening components must be fixed firmly and securely Risk of injury The appliance is heavy To move the appliance 2 people are required Use only suitable tools and equipment Risk of injury Changes to the electrical or mechanical assembly are dangerous and may lead to malfunctions Do not make any changes to the electrical or mechanical assembly Warning Risk of electric shock Components inside the ap...

Page 13: ...power supply The appliance must only be connected to a protective contact socket that has been correctly installed If the plug can no longer be reached after installation an energy isolating device in the phases must be provided in the permanent electrical installation in accordance with the installation regulations The permanent electrical installation must only be wired by a professional electri...

Page 14: ...en Installation 14 Installation 1 Attaching and aligning the appliance 2 Mark the hole for the safety screw 3 Remove the appliance once more ª ...

Page 15: ...ns Use sealing strips for deviating pipe diameters Connecting the appliance to the power supply Connecting the air extractor Note If using an aluminium pipe smooth the connection area beforehand 1 Attach the air extractor pipe directly to the air pipe connector 2 Connect to air extractor opening 3 Seal the joints appropriately Connect the power supply 1 Plug the mains plug into the earthed socket ...

Page 16: ...Robert Bosch Hausgeräte GmbH www bosch home com Carl Wery Straße 34 81739 München GERMANY 9001283712 9001283712 970810 ...

Reviews: