DS860 Series Installation Instructions

P/N: 29703K     Page 4

Long Range Barrier Coverage

Meters

30

0
Feet

100

0

5

5

TOP VIEW

10

20

30

40

50

60

70

80

90

3

6

9

12

15

18

21

24

27

0

0

1.5

1.5

A

B

C

D

Meters

30

0
Feet

100

0

10

SIDE VIEW

10

20

30

40

50

60

70

80

90

3

6

9

12

15

18

21

24

27

0

-3°

3 Meters

A

B

C

D

7.5

2.3

Look-Down

10.1 Pattern Masking

The PIR coverage pattern may be masked using masking tape or
electrical tape on the inside (grooved side) of the lens to cover the
appropriate pattern areas as shown in the following illustrations.
Always walk test for the desired coverage after masking.

A B C D E F G H I

N J Q K O L R M P

DS860 Standard Lens

A

B
C

D

Optional Long Range

Barrier Lens

NOTE:

Masking only eliminates the PIR portion of the coverage
and has no effect on the microwave pattern.

Summary of Contents for DS860 Series

Page 1: ... may cause undesirable operation Changes or modifications not expressly approved by Bosch Security Systems can void the user s authority to operate the equipment 2 0 Installation Considerations NOTE The DS860 is not recommended for installations containing pets or small animals Use the DS820 or DS835 for such installations Never install the detector in an environment that causes an alarm condition...

Page 2: ...Pins For selection place the plug across the pins marked STD for Standard or INT for Intermediate mode Standard Sensitivity The recommended setting for maximum false alarm immunity Tolerates environmental extremes on this setting Intermediate Sensitivity The recommended setting for any location where an intruder is expected to cover only a small portion of the protected area Tolerates normal envir...

Page 3: ... 3 Establishing Detector Coverage The tri color LED should be OFF before walk testing Walk test the unit from all directions to determine the detection boundaries A detector alarm is signaled by the first red activation of the tri color LED after an initial green or yellow activation 8 0 Supervision Features The supervision features function as follows PIR Microwave The complete circuit operation ...

Page 4: ...IDE VIEW 10 20 30 40 50 60 70 80 90 3 6 9 12 15 18 21 24 27 0 3 3 Meters A B C D 7 5 2 3 Look Down 10 1 Pattern Masking The PIR coverage pattern may be masked using masking tape or electrical tape on the inside grooved side of the lens to cover the appropriate pattern areas as shown in the following illustrations Always walk test for the desired coverage after masking A B C D E F G H I N J Q K O L...