Bosch DS860 Series Installation Instructions Download Page 1

Installation Instructions

for the DS860 Series

TriTech Microwave/PIR Intrusion Detectors

1.0

Specifications

Dimensions (HxWxD): 5 in. x 2.8 in. x 2.2 in.

(12.7 cm x 7.1 cm x 5.6 cm)

Input Power:

9 to 15 VDC, 16 mA DC nominal
(up to 48 mA DC during walk testing or
trouble conditions). Useonly an
Approved Limited Power Source.

Standby Power:

No internal standby battery.
Standby power must be provided by
an Approved Limited Power Source.
Sixteen mAh required for each hour of
standby time needed. 

For UL Listed

Requirements, four hours (64 mAh)
minimum are required.

Alarm Relay:

Silent operating Normally Closed
reed relay. Contacts rated 3 watts,
125 mA, 28 VDC maximum for DC
resistive loads; and protected by a
4.7 ohm, 0.5 watt resistor in the
common "C" leg of the relay. To be
connected to a SELV (Safety Extra-Low
Voltage) circuit only. Do not use with
capacitive or inductive loads.

Temperature Range:

-40°F to +120°F (-40°C to +49°C).
For UL Listed Requirements, the
temperature range is +32°F to +120°F
(0°C to +49°C).

Microwave Frequency:

DS860:

10.525 GHz (UL Listed)

DS860A:

10.687 GHz (Export only, not UL
Listed)

DS860B:

9.9 GHz (Export only, not UL Listed))

Coverage:
Broad (standard):

60 ft. by 60 ft. (18 m by 18 m)

Long Range (optional): 100 ft. by 10 ft. (30 m by 3 m)

Internal Pointability:

+2° to –10° Vertical, ±10° Horizontal.

Tamper:

Normally Closed (with cover on).
Contacts rated at 28 VDC, 125 mA
max. To be connected to a SELV
(Safety Extra-Low Voltage) circuit
only. Connect tamper circuit to 24-hour
protection circuit.

Options:

B328 Gimbal Mount Bracket, B335
Low Profile Swivel Mount Bracket,
B338 Ceiling Mount Bracket, OLR92
Long Range Barrier Lens

NOTE:

Use of a bracket may reduce range and increase dead
zone areas.

U.S. Patent Numbers:  Protected under one or more of the
following U.S. Patent Numbers:  #4,660,024, #4,764,755,
#5,077,548, #5,208,567,  #5,262,783, and #5,450,062. Other
patents pending.

Compliance:  This device complies with Part 15 of the FCC
Rules and with RSS-210 of Industry and Science Canada.
Operation is subject to the following two conditions:

(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,

including interference that may cause undesirable
operation.

Changes or modifications not expressly approved by Bosch
Security Systems can void the user’s authority to operate the
equipment.

2.0

Installation Considerations

NOTE:

The DS860 is not  recommended for installations
containing pets or small animals. Use the DS820 or
DS835 for such installations.

Never install the detector in an environment that causes an
alarm condition in one technology. Good installations start with
the LED OFF when there is no target motion. It should never be
left to operate with the tri-color LED in a constant or intermittent
green, yellow, or red condition.

Point the unit away from outside traffic (roads/alleys).

NOTE:

Microwave energy will pass through glass and most
common non-metallic construction walls.

Avoid installations where rotating machines (e.g. ceiling fans)
are normally in operation within the coverage pattern. Point the
unit away from glass exposed to the outdoors and objects that
may change temperature rapidly.

NOTE:

The PIR detector will react to objects rapidly changing
temperature within its field-of-view.

Eliminate interference from nearby outside sources.

3.0

Mounting

Select a location likely to intercept an intruder moving across
the coverage pattern. The surface should be solid and
vibration-free. Mounting height range is 6 to 8 ft. (1.8 to
2.4 m). Recommended mounting height is 7.5 ft. (2.3 m).

Remove the cover. Insert a flathead screwdriver into the locking
tab hole at the bottom front of the detector. Pull the cover up
and forward.

Vertical

Adjust

Screw

Tri-color

LED

Terminal

Strip

LED

On/Off

Pins

MW

- 4°
- 8°

On

Off

Microwave

Range Adjust

PIR

Sensitivity

Selection Pins

Vertical Adjust

 Scale

Look Down Lens

MIN

MAX

Face of Lens
 (masking area)

Corner Mount

Knockout (4)

Surface Mount

Knockout (2)

Wire
Entrances

Bracket Mount

Knockout

Vertical Adjust
Screw Mount

Cover Tab and

Locking Screw Hole

Wire
Entrances

Remove the circuit board from the base. Loosen the Vertical
Adjust Screw and slide the circuit board down, then out.

Break away the appropriate thin-wall wire entrance and
mounting hole coverings in the base.

Using the base as a template and aligning it so that the
detector will be mounted with the terminal block at the top and
the PIR lens at the bottom, mark the location of the mounting
holes on the mounting surface. Pre-start the mounting screws.

Summary of Contents for DS860 Series

Page 1: ... may cause undesirable operation Changes or modifications not expressly approved by Bosch Security Systems can void the user s authority to operate the equipment 2 0 Installation Considerations NOTE The DS860 is not recommended for installations containing pets or small animals Use the DS820 or DS835 for such installations Never install the detector in an environment that causes an alarm condition...

Page 2: ...Pins For selection place the plug across the pins marked STD for Standard or INT for Intermediate mode Standard Sensitivity The recommended setting for maximum false alarm immunity Tolerates environmental extremes on this setting Intermediate Sensitivity The recommended setting for any location where an intruder is expected to cover only a small portion of the protected area Tolerates normal envir...

Page 3: ... 3 Establishing Detector Coverage The tri color LED should be OFF before walk testing Walk test the unit from all directions to determine the detection boundaries A detector alarm is signaled by the first red activation of the tri color LED after an initial green or yellow activation 8 0 Supervision Features The supervision features function as follows PIR Microwave The complete circuit operation ...

Page 4: ...IDE VIEW 10 20 30 40 50 60 70 80 90 3 6 9 12 15 18 21 24 27 0 3 3 Meters A B C D 7 5 2 3 Look Down 10 1 Pattern Masking The PIR coverage pattern may be masked using masking tape or electrical tape on the inside grooved side of the lens to cover the appropriate pattern areas as shown in the following illustrations Always walk test for the desired coverage after masking A B C D E F G H I N J Q K O L...

Reviews: