DS3MX-E-U
Page 2 of 2
7.0
Bypassing a Zone
Enter PIN, press [Bypass], enter the zone
number, and press [On]
A user can bypass a zone during the arming
sequence if it was programmed at installation to
allow bypass. You can bypass a zone if the zone is
either faulted or normal. To bypass a zone, enter
the User code or the Master code. Press the
[Bypass] key. Enter the zone number to bypass
(such as, Zone 1, Zone 2, or Zone 3, or any
combination of Zones 1, 2, or 3).
For example: To enter Zone 1, press the [1] key,
then press the [On] key to begin the arming cycle
and exit delay, if programmed. All zones that were
bypassed will clear and automatically restore to
their normal mode the next time the system
disarms.
Once a zone is bypassed, the zone’s LED indicates
its bypass status by flashing twice every 2 seconds.
8.0
Fire Alarm Reset
Enter PIN, press [Reset]
Use the Fire Reset for power interrupt and to reset
the smoke detectors. This function must be installed
and programmed at installation. Only the Master
code user can perform this function.
9.0
Door Un-Lock Code
Enter PIN, press [*]
If enabled, entering the Door Un-Lock User code
and pressing the [*] key activates the Request to
Exit function, releasing any connected door lock.
Table 1:
Zone Status
NAME
STATUS
DESCRIPTION
Zone 1
On
Zone 1
alarmed/violated
Off
Zone 1 normal
Flashing
(0.5 seconds on, 0.5
seconds off)
Zone 1 alarm
history
Flashes twice every 2
seconds
Zone 1 bypassed
Zone 2
On
Zone 2
alarmed/violated
Off
Zone 2 normal
Flashing
(0.5 seconds on, 0.5
seconds off)
Zone 2 alarm
history
Flashes twice every 2
seconds
Zone 2 bypassed
Zone 3
On
Zone 3
alarmed/violated
Off
Zone 3 normal
Flashing
(0.5 seconds on, 0.5
seconds off)
Zone 3 alarm
history
Flashes twice every 2
seconds
Zone 3 bypassed
Armed
Flashing
(0.5 seconds on; 0.5
seconds off)
Exit delay
On
System armed
Off
System disarmed
Power
On
Power supply
normal
Off
No power supply