
Bosch Security Systems | 1/05 | 4998122424F
EN |
4
5.0
Configuration
5.1
Program Jumper for the S/U Control
Terminal
Use the S/U control terminal as an alarm memory
control input by setting the jumper in the upper position
as shown in
Item 1
of
Figure 6
.
Use the S/U control terminal as an electronic alarm
output (open collector) by setting the jumper in the
lower position as shown in
Item 2
of
Figure 6
.
5.2
User DIP Switches
5.3
Adjusting Sensitivity
Table 1: Sensitivity Settings
DIP Switch 2 OFF
Standard Sensitivity (Default):
Recommended for maximum false
alarm prevention.
Tolerates environmental extremes.
Not recommended for curtain
patterns.
DIP Switch 2 ON
Intermediate Sensitivity:
Recommended for any location
where an intruder is expected to
cover only a small portion of the
protected area, or when you want
improved catch performance.
Does not tolerate normal
environments.
5.4
LED Setup Without S/U and WT
Remote Control Panel Inputs
Table 2: LED Setup Without Control Panel Inputs
DIP Switch Settings
LED
Operation
User DIP Switch 1
Walk Test
User DIP Switch 3
Set/Unset
Disable LED
Any
ON
Enable LED
OFF (default)
OFF (default)
5.0 Configuration
Figure 7:
User DIP Switches
3
1
2
1
2
3
OPEN
1 - Walk Test polarity (Refer to
Section 5.4 LED
Setup Without S/U and WT Remote Control
Panel Inputs.
)
2 - Sensitivity (Refer to
Section 5.5 Setup for
Remote Control Alarm Memory and LED
Operation Using S/U and WT Inputs.
)
3 - Set/Unset polarity (Refer to
Section 5.4.
)
1 - Alarm memory control input
2 - Electronic alarm output
Figure 6:
Program Jumper Settings
2
1
S/U
AL
S/U
AL
DS304
| Installation Instructions |