Basic operation
en
7
2.
Press repeatedly until LED 5 lights up in the LED
display for intensive mode 2.
a
After approx. 6 minutes, the appliance automatically
switches to fan setting 3.
Switching off intensive mode
▶
To select a fan setting of your choice, press .
a
After approx. 6 minutes, the appliance automatically
switches to fan setting 3.
Switching on the fan run-on
▶
Press .
a
LED 1 for the fan setting lights up in the LED dis-
play. LED 6 flashes for the fan run-on.
a
The appliance switches off automatically after ap-
prox. 10 minutes.
Switching off the fan run-on
▶
Press .
a
This immediately stops the fan run-on.
a
The appliance switches to the fan setting that was
previously selected.
Switch on automatic mode
1
The optimum fan setting is set automatically using a
sensor.
▶
Press .
a
In the LED display, LED 6 lights up for automatic
mode.
Switch off automatic mode
1
▶
Press .
a
The appliance switches to the fan setting that was
previously set.
a
The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a
Automatic mode runs for a maximum of four hours.
Intermittent ventilation
With interval ventilation, the ventilation system switches
on and off in the selected setting for the selected time.
Note:
This function is only available via a mobile device
with the Home Connect app.
If the interval ventilation is switched on, LED 6 continu-
ously flashes in the LED display for the interval ventila-
tion and the LED for the selected fan setting lights up.
As soon as the ventilation time ends, the LED for the
fan setting you have selected goes out. LED 6 contin-
ues to flash.
Sensor control
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting automatically switched on.
If the sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡
Default setting: Fan setting 3
¡
Lowest setting: Fan setting 1
¡
Highest setting: Fan setting 5
Setting the sensor control
Requirement:
The appliance is switched off.
1.
Press and hold and for approx. three seconds.
2.
Press or to change the setting.
To cancel the setting, press .
3.
To save the setting, press and hold and for ap-
prox. three seconds.
Or wait approx. 10 seconds until the setting is
saved automatically.
a
A signal tone sounds as soon as the selected set-
ting is saved.
Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement:
The appliance is switched off.
1.
Press and hold and for approx. three seconds.
‒
To set circulating-air mode (non-regenerable fil-
ter), press / until LED 2 lights up in the LED
display.
‒
To set circulating-air mode (non-regenerable fil-
ter), press / until LED 3 lights up in the LED
display.
‒
To convert the electronic control back to opera-
tion without the air recirculation filter, press /
until LED 1 lights up on the LED display.
2.
To save the setting, press and hold and for ap-
prox. three seconds.
Or wait approx. 10 seconds until the setting is
saved automatically.
To cancel the setting, press .
a
A signal tone sounds as soon as the selected set-
ting is saved.
Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡
After the appliance has been switched off, LED 1
flashes in the LED display for the grease filter satura-
tion display and/or LED 2 flashes for the saturation
indicator for the odour filter.
¡
A repeated signal tone sounds.
▶
Press .
a
The saturation indicator is reset.
1