background image

Instruction Manual

EN

Integrated Fixed Dome

DME Series

Summary of Contents for DMExPCHxx

Page 1: ...Instruction Manual EN Integrated Fixed Dome DME Series ...

Page 2: ...on completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from battery power refer to the operating instructi...

Page 3: ...a fire or electrical shock Never spill liquid of any kind on the unit 3 Power Cord and Power Cord Protection For units intended to operate with 230VAC 50Hz the input and output power cord must comply with the latest versions of IEC Publication 227 or IEC Publication 245 Power supply cords should be routed so they are not likely to be walked on or pinched Pay particular attention to location of cor...

Page 4: ...die Bedienung und Instandhaltung Wartung in den begleitenden Unterlagen informieren Precauciones de Seguridad Atención la instalación la debe realizar únicamente personal cualificado de conformidad con el National Electric Code o las normas aplicables en su país Desconexión de la alimentación Las unidades con o sin interruptores de encendido apagado reciben alimentación eléctrica siempre que el ca...

Page 5: ...sse elettriche Si consiglia di consultare le istruzioni operative e di manutenzione interventi tecnici contenute nella documentazione fornita con il dispositivo Medidas de Segurança Atenção a instalação deve ser executada apenas por técnicos qualificados da assistência de acordo com o código eléctrico nacional ou os códigos locais aplicáveis Corte de corrente As unidades com ou sem interruptores O...

Page 6: ...In ceiling Model DMExRx Series 6 4 2 Pendant Model DMExPx Series 8 4 2 1 Conduit Pipe Mounting 8 4 2 2 Wall Mounting 8 4 3 Camera Adjustments 9 4 4 Remote Video Setup 10 5 CAMERA LENS SETTINGS 11 5 1 Line Lock Phase Backlight Compensation Setting 11 6 SPARE PARTS ACCESSORIES 12 ...

Page 7: ...ce the customer should contact the nearest Bosch Security Systems Service Center for return authorization and shipping instructions Service Centers U S A phone 800 366 2283 or 717 735 6638 fax 800 366 1329 or 717 735 6639 email BoschCCTVparts ca slr com Canada 514 738 2434 Europe Middle East Asia Pacific Region 32 1 440 0711 For additional information see www boschsecurity com 4 INSTALLATION ATTEN...

Page 8: ...ion fold out and screw down to secure unit Figure 1 Ceiling Mount Power Video Connections 2 Install the base assembly box into the precut hole until the base s flange hits the ceiling Tighten the three screws that serve to lower the mounting clamps to grab on to the ceiling Be sure the clamps are secure against the ceiling see Figure 2 3 Adjust the camera module for proper viewing angle See Sectio...

Page 9: ...shown in Figure 3 Conduit and conduit nuts are not supplied Figure 3 Pendant Pipe Mount Installation 3 Route power video cables to the terminal block and BNC connector located on the back of the housing and make proper connections See Figure 1 4 Attach base camera lens unit to pendant cap by lining up and joining the cap s four studs to the slots located on the back of the base unit Twist the hous...

Page 10: ...cluded Electrical Box Mounting Option Hole pattern in mounting plate matches a North American double outlet electrical box Use four screws included to secure the wall arm to the box Make sure box is securely anchored Figure 4 Pendant Wall Mount Installation 4 3 Camera Adjustments 1 The camera can manually pan tilt or rotate 360 degrees See Figure 5 for a diagram of these adjustments Figure 5 Camer...

Page 11: ...tor Refer to the following steps for this procedure 1 After the power and video connections are made to the camera and the dome is mounted correctly connect the setup coax cable with BNC located next to the camera lens module to the remote monitor See Figure 6a for an example of a simple setup configuration Figure 6a Example of Setup Configuration Using Remote Monitor 2 Disconnect the video connec...

Page 12: ...k is on the backlight compensation is off and the white balance is on Figure 7 Camera Assembly CAMERA MODULE ADJUSTMENTS AND CONNECTIONS A Power Block 1 Supply 2 Secondary GND Do not connect 3 Supply Supply accepts 24 Vac or 12 Vdc polarity independent galvanically isolated from video GND B Video Cable Output Connection C DC Iris Cable Connection D Vphase Adjustment Adjust control until desired se...

Page 13: ...2 Pendant Cap 315 3741 003 Mounting Clamps Screws 3 sets 315 3741 004 Lens 3 8 mm DC Iris LEN 3 08 0AI T Lens 5 50 mm DC Iris LTC 3374 20 Accessories Description Part No Conduit Adapter for 1 inch Conduit 315 3741 005 Plenum Rated Backbox DMEBX Plenum Rated Backbox and Support Rails DMEBXR Wall Mount MTDMEW 12 ...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ... security sales us bosch com http www boschsecurity us Europe Middle East Africa Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 0 40 27 83955 Fax 31 0 40 27 86668 emea securitysystems bosch com http www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosch ...

Reviews: