Bosch DIVAR IP 2000 Installation Manual Download Page 4

Safety precautions

Observe the safety precautions in this chapter.
 

General safety precautions

Follow these rules to ensure general safety:

Keep the area around the system clean and free of clutter.

Place the chassis top cover and any system components that have been removed away
from the system or on a table so that they won't accidentally be stepped on.

While working on the system, do not wear loose clothing such as neckties and
unbuttoned shirt sleeves, which can come into contact with electrical circuits or be
pulled into a cooling fan.

Remove any jewelry or metal objects from your body, which are excellent metal
conductors that can create short circuits and harm you if they come into contact with
printed circuit boards or areas where power is present.

!

Warning!
Interruption of mains supply:
Voltage is applied as soon as the mains plug is inserted into the mains socket.
However, for devices with a mains switch, the device is only ready for operation when the
mains switch (ON/OFF) is in the ON position. When the mains plug is pulled out of the
socket, the supply of power to the device is completely interrupted.

!

Warning!
Removing the housing:
To avoid electric shock, the housing must only be removed by qualified service personnel.
Before removing the housing, the plug must always be removed from the mains socket and
remain disconnected while the housing is removed. Servicing must only be carried out by
qualified service personnel. The user must not carry out any repairs.

!

Warning!
Power cable and AC adapter:
When installing the product, use the provided or designated connection cables, power cables
and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fire.
Electrical Appliance and Material Safety Law prohibits the use of UL or CSA-certified cables
(that have UL/CSA shown on the code) for any other electrical devices.

!

Warning!
Lithium battery:
Batteries that have been inserted wrongly can cause an explosion. Always replace empty
batteries with batteries of the same type or a similar type recommended by the manufacturer.
Handle used batteries carefully. Do not damage the battery in any way. A damaged battery
may release hazardous materials into the environment.
Dispose of empty batteries according to the manufacturer's instructions.

1

1.1

4

en | Safety precautions

DIVAR IP 2000

2013.05 | V1 | DOC

Installation Manual

Bosch Sicherheitssysteme GmbH

Summary of Contents for DIVAR IP 2000

Page 1: ...DIVAR IP 2000 DIP 2040 00N DIP 2042 2HD DIP 2042 4HD en Installation Manual ...

Page 2: ......

Page 3: ...vice views 8 2 3 1 LED description front panel 9 2 3 2 LAN port LED description rear panel 10 3 Chassis setup and maintenance 11 3 1 Removing hard drive trays 11 3 2 Installing a hard drive 11 4 System setup first steps 12 4 1 Introduction 12 4 2 Setup instruction 12 4 3 Starting the application 12 4 4 Using Configuration Wizard 13 5 Recovering the unit 22 6 Additional Documentation 23 DIVAR IP 20...

Page 4: ...ce is completely interrupted Warning Removing the housing To avoid electric shock the housing must only be removed by qualified service personnel Before removing the housing the plug must always be removed from the mains socket and remain disconnected while the housing is removed Servicing must only be carried out by qualified service personnel The user must not carry out any repairs Warning Power...

Page 5: ... harm and the system from damage Be aware of the locations of the power on off switch on the chassis as well as the room s emergency power off switch disconnection switch or electrical outlet If an electrical accident occurs you can then quickly remove power from the system Do not work alone when working with high voltage components Power should always be disconnected from the system when removing...

Page 6: ...signed to prevent static discharge Keep all components and printed circuit boards PCBs in their antistatic bags until ready for use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or printed circuit boards come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only Do not...

Page 7: ...IVAR IP 2000 is ready to begin recording straight out of the box DIVAR IP 2000 features front swappable SATA II hard drives providing up to 8 TB of gross storage capacity All system software is pre installed and pre activated creating an out of the box ready to use video recording appliance DIVAR IP 2000 utilizes Windows Storage Server 2008 R2 operating system Chassis features The chassis includes...

Page 8: ...health of specific components This chapter explains the meanings of all LED indicators Front view 1 5 2 3 4 6 1 Lock for front cover 4 LAN activity LED 2 Power on off LED 5 System status LED 3 Hard disk access LED 6 Individual hard disk LED 2 3 8 en System overview DIVAR IP 2000 2013 05 V1 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Page 9: ...bes the LED displays on the front of the chassis LED indicator LED color LED state Description Power LED N A Off Power off Blue On default Working S0 state HDD LED N A Off No disk access Blue Blinking Disk access LAN LED N A Off Network disconnected Blue On Network connected Blue Blinking Network activity System LED N A Off Power off 2 3 1 DIVAR IP 2000 System overview en 9 Bosch Sicherheitssystem...

Page 10: ...t Blue On Hard drive present Red On Bosch provides the API to let application program to control this status LAN port LED description rear panel This chapter describes the LAN port LED on the rear of the chassis LAN connector 1 2 Nr LED indicator LED color LED state NIC state 1 RJ45 LED left N A Off No connection or 10 Mb s Green On 100 Mb s Yellow On 1000 Mb s 2 RJ45 LED right Yellow On Active co...

Page 11: ...er handle is completely closed Notice Except for short periods of time do not operate the unit with the hard drives removed from the bays Installing a hard drive The drives are mounted in drive carriers To install a hard drive to the hard drive carrier 1 Remove the drive from the carrier 2 Install a new drive into the carrier with the printed circuit board side facing down so that the mounting hol...

Page 12: ...a default IP address and with default iSCSI settings IP Address 192 168 178 200 Subnet mask 255 0 0 0 User Administrator Password WSS4Bosch The default iSCSI settings are optimized for use with VRM Notice We strongly recommended not changing these settings Changing these settings can result in malfunctioning of the system Starting the application DIVAR IP system is ready to go out of the box The a...

Page 13: ...e users and set passwords Configuration Wizard can access Management Server only on the local computer Configuration Wizard adds the local VRM automatically To achieve a quick configuration using the Configuration Manager Wizard 1 On the default screen double click the Configuration Wizard icon The Welcome page is displayed 2 Run through the following pages of the wizard Welcome page 4 Click Next ...

Page 14: ...ecify a password to protect the devices from unauthorized access 4 Enter the respective password confirm the password then click Next 14 en System setup first steps DIVAR IP 2000 2013 05 V1 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Page 15: ...Recorder page This page displays recorder information 4 Click Next to continue DIVAR IP 2000 System setup first steps en 15 Bosch Sicherheitssysteme GmbH Installation Manual 2013 05 V1 DOC ...

Page 16: ...splays all network devices that are added to the system Clicking Update starts the scan process again 4 Click Next to continue 16 en System setup first steps DIVAR IP 2000 2013 05 V1 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Page 17: ...e This page allows you to configure the network settings of connected devices 4 Click Next to continue DIVAR IP 2000 System setup first steps en 17 Bosch Sicherheitssysteme GmbH Installation Manual 2013 05 V1 DOC ...

Page 18: ...page allows you to synchronize the device time with the computer time or a SNTP time server 4 Click Next to continue 18 en System setup first steps DIVAR IP 2000 2013 05 V1 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Page 19: ...age allows you to define the image quality for live viewing and to set the maximum bandwidth 4 Click Next to continue DIVAR IP 2000 System setup first steps en 19 Bosch Sicherheitssysteme GmbH Installation Manual 2013 05 V1 DOC ...

Page 20: ...ecording page This page allows you to define the recording profiles 4 Click Next to continue 20 en System setup first steps DIVAR IP 2000 2013 05 V1 DOC Installation Manual Bosch Sicherheitssysteme GmbH ...

Page 21: ...page This page displays a summary of all wizard settings 4 Click Apply to activate the configuration DIVAR IP 2000 System setup first steps en 21 Bosch Sicherheitssysteme GmbH Installation Manual 2013 05 V1 DOC ...

Page 22: ...n the HDDs will not be deleted Note Windows performs the setup The screen displays the percentage of the process Notice Do not turn off the unit during the process This will damage the Recovery media 3 The unit starts from the Recovery media If the setup is successfull press Yes to restart the system 4 Windows performs the initial setup of the operating system The unit restarts after Windows has c...

Page 23: ...s www boschsecurity com select your region and your country select Product Catalog start a search for your product select the product in the search results to show the existing documents 6 DIVAR IP 2000 Additional Documentation en 23 Bosch Sicherheitssysteme GmbH Installation Manual 2013 05 V1 DOC ...

Page 24: ......

Page 25: ......

Page 26: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2013 ...

Reviews: