background image

 

 

 

 

 

 

DIVAR IP 6000 2U

DIP-6080-00N, DIP-6082-8HD

 

 

en

Quick Installation Guide

 

Summary of Contents for DIVAR DIP-6080-00N

Page 1: ...DIVAR IP 6000 2U DIP 6080 00N DIP 6082 8HD en Quick Installation Guide ...

Page 2: ......

Page 3: ... 3 4 1 Separating the sections of the rack rails 12 3 4 2 Installing the inner rails 13 3 4 3 Installing the outer rails to the rack 13 3 4 4 Installing the chassis into the rack 14 3 4 5 Installing the chassis into a Telco rack 15 3 5 Turning on the system 15 4 System Setup first Steps 16 4 1 Introduction 16 4 2 Setup instruction 16 4 3 Setting the IP address 16 4 3 1 Remote desktop connection 16...

Page 4: ...ibute the weight Always keep your back straight and lift with your legs Warning Interruption of mains supply Voltage is applied as soon as the mains plug is inserted into the mains socket However for devices with a mains switch the device is only ready for operation when the mains switch ON OFF is in the ON position When the mains plug is pulled out of the socket the supply of power to the device ...

Page 5: ... symbol means that electronic and electrical devices that have reached the end of their working life must be disposed of separately from household waste In the EU separate collecting systems are already in place for used electrical and electronic products Please dispose of these devices at your local communal waste collection point or at a recycling center Electrical safety precautions Basic elect...

Page 6: ...ferent electrical charges coming into contact with each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD Do not use mats designed to decrease electrostatic discharge as protect...

Page 7: ... uneven surfaces may cause the cart unit combination to overturn Mount the unit per the manufacturer s instructions FCC and ICES compliance only for U S A and Canada This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equi...

Page 8: ...o despite low or limited bandwidth connections Dynamic Transcoding technology ensures that you can view your video immediately anytime anywhere Remote viewing DIVAR IP 6000 comes with our advanced Video Client for remote viewing Video Client is a Windows PC application for live viewing and playback including Configuration Manager Configuration Manager allows the settings of the DIVAR IP 6000 be co...

Page 9: ... 2x mains connection 100 240 VAC 50 60 Hz 4 Serial interface COM1 2 2x PS 2 5 Monitor VGA 3 2x USB 6 2x Ethernet RJ45 DIVAR IP 6000 2U System overview en 9 Bosch Sicherheitssysteme GmbH Quick Installation Guide 2013 05 V3 DOC ...

Page 10: ...rocess in a minimum amount of time Read this section before you begin the installation procedure outlined in the sections that follow Choosing a setup location Situate the system in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Place the system near a grounded power outlet Leave approximately 25 inches clearance in f...

Page 11: ...g them Always keep the rack s front door and all panels and components on the system closed when not servicing to maintain proper cooling See also Safety precautions page 4 Rack mounting considerations Ambient operating temperature If installed in a closed or multi unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room T...

Page 12: ...ating the sections of the rack rails The chassis package includes two rail assemblies in the rack mounting kit Each assembly consists of two sections an inner fixed chassis rail that secures directly to the chassis an outer fixed rack rail that secures directly to the rack itself To separate the inner and outer rails 1 Locate the rail assembly in the chassis packaging 2 Extend the rail assembly by...

Page 13: ...ils 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre attached inner rail 2 Slide the extension toward the front of the chassis 3 Secure the chassis with 2 screws as illustrated 4 Repeat steps for the other inner rail extension Installing the outer rails to the rack Ou...

Page 14: ...cing Installing the chassis into the rack To install the chassis into a rack 1 Extend the outer rails as illustrated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws may...

Page 15: ...oned with just enough space to accommodate the width of the Telco rack Finish by sliding the chassis into the rack and tightening the brackets to the rack Turning on the system The last thing to be done is to provide input power to the system To turn on the system 1 Plug the power cord from the power supply unit into a high quality power strip that offers protection from electrical noise and power...

Page 16: ... 10 10 11 2nd port Subnet mask 255 255 255 0 User Administrator Password WSS4Bosch The default iSCSI settings are optimized for use with VRM Only an experienced storage administrator should make changes to these settings Changing the default configuration is only required if VRM is not used DIVAR IP 6000 as standard iSCSI disk array The default settings are not appropriate for another Bosch iSCSI ...

Page 17: ...e desktop default settings are applied This will take a few seconds and the system will reboot After system reboot log on again and the Bosch VRM Appliance initial configuration window will be shown Use this program to configure the disk array s IP Address 2 The top level view of Bosch VRM Appliance initial configuration displays an overview of the system s configuration and settings Select the li...

Page 18: ...icon 3 Click Properties select Internet Protocol Version 4 TCP IPv4 then click Properties 4 This dialog box allows you to set the IP address configuration according to the requirements of your network 5 Reboot the system 18 en System Setup first Steps DIVAR IP 6000 2U 2013 05 V3 DOC Quick Installation Guide Bosch Sicherheitssysteme GmbH ...

Page 19: ...ystem on first login the desktop default settings are applied This will take a few seconds and the system will reboot After system reboot log on again and the Bosch VRM Appliance initial configuration window will be shown Use this program to configure the disk array s IP Address 2 The top level view of Bosch VRM Appliance initial configuration displays an overview of the system s configuration and...

Page 20: ...n click Properties 4 This dialog box allows you to set the IP address configuration according to the requirements of your network 5 Reboot the system 20 en System Setup first Steps DIVAR IP 6000 2U 2013 05 V3 DOC Quick Installation Guide Bosch Sicherheitssysteme GmbH ...

Page 21: ...view of the Bosch VRM Appliance initial configuration window displays an overview of the system s configuration and settings If the Bosch VRM Appliance initial configuration window is not displayed click Start Run oobe 2 Select the link Disable Enable Bosch VRM Appliance to stop start the VRM recording service To restart the service again 4 On the Bosch VRM Appliance initial configuration window c...

Page 22: ...r all viewing related configuration tasks IVA for example the VRM configurator along with the Bosch Video SDK available from the Bosch web site must be installed on a separate client system Documentation for Bosch Security System products can be found as follows www boschsecurity com select your region and your country select Product Catalog start a search for your product select the product in th...

Page 23: ...sch ST RMA Swapstock 8601 East Cornhusker Hwy Lincoln NE 68507 USA Phone 1 402 467 6610 Fax n a E mail repair us bosch com Opening Hours Monday to Friday 06 00 16 30 RMA Desk APR Robert Bosch SEA Pte Ltd 11 Bishan Street 21 level 5 from service lift Singapore 573943 Phone 65 6571 2872 Fax n a Email rmahelpdesk sg bosch com Opening Hours Monday to Friday 08 30 17 45 RMA contact China Bosch Zhuhai S...

Page 24: ......

Page 25: ......

Page 26: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2013 ...

Reviews: