background image

 

 

 

 

 

 

DIVAR IP 6000 1U

DIP-6040-00N, DIP-6042-4HD, DIP-6043-4HD

 

 

en Installation manual

 

Summary of Contents for DIP-6040-00N

Page 1: ...DIVAR IP 6000 1U DIP 6040 00N DIP 6042 4HD DIP 6043 4HD en Installation manual ...

Page 2: ......

Page 3: ...ves 14 3 2 1 Removing hard drive trays 14 3 2 2 Installing a hard drive 15 3 3 Installing a DVD ROM or floppy drive 17 3 4 Replacing the internal transcoder device 17 3 5 Installing the motherboard 18 3 6 Installing the air shroud 18 3 7 System fans 19 3 8 Power supply 20 3 8 1 Power supply failure 20 4 Rack installation 22 4 1 Unpacking the system 22 4 2 Preparing for setup 22 4 2 1 Choosing a se...

Page 4: ...toring 35 5 4 Power configuration settings 35 5 5 Power supply 36 5 6 Super I O 36 5 7 iSCSI support 36 5 8 Overview of the Nuvoton BMC controller 37 5 9 RAID disaster recovery 37 5 9 1 Multiple disks failed theory 38 5 9 2 Multiple disks failed practice 43 5 9 3 Foreign configuration disk appears in the Windows GUI after booting 46 5 9 4 MegaCLI Commandline Utility 47 4 en Table of Contents DIVAR...

Page 5: ...istribute the weight Always keep your back straight and lift with your legs Warning Interruption of mains supply Voltage is applied as soon as the mains plug is inserted into the mains socket However for devices with a mains switch the device is only ready for operation when the mains switch ON OFF is in the ON position When the mains plug is pulled out of the socket the supply of power to the dev...

Page 6: ...his symbol means that electronic and electrical devices that have reached the end of their working life must be disposed of separately from household waste In the EU separate collecting systems are already in place for used electrical and electronic products Please dispose of these devices at your local communal waste collection point or at a recycling center Electrical safety precautions Basic el...

Page 7: ...different electrical charges coming into contact with each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD Do not use mats designed to decrease electrostatic discharge as prot...

Page 8: ... or uneven surfaces may cause the cart unit combination to overturn Mount the unit per the manufacturer s instructions FCC and ICES compliance only for U S A and Canada This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the e...

Page 9: ...emote viewing Video Client is a Windows PC application for live viewing and playback including Configuration Manager Configuration Manager allows the settings of the DIVAR IP 6000 be configured A stand alone archive player will allow archive playback and authentication without any other workstation software For information on supported hardware see the datasheet for DIVAR IP 6000 in the Bosch Onli...

Page 10: ...age and use To setup your rack follow the step by step instructions included in this manual Power supply Each chassis model includes 2 high efficiency power supplies redundant In the unlikely event your power supply fails replacement is simple and can be accomplished without tools Air shroud Air shrouds are shields usually plastic which conduct the airflow directly to where it is needed Always use...

Page 11: ...ation LED Universal Information LED States Fast blinking red 1x sec Fan failure Solid red CPU overheat Note Can be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Slow blinking red 1x 4 sec Power failure Solid blue Local UID button depressed Blinking blue IPMI activated UID Note Deactivating the UID LED must be performed in the same way it was ...

Page 12: ...A drives fail you should be notified by your system management software Power supply LEDs and overheat indicators This chassis provides several options which may include hot swappable cold swappable and redundant power supplies Some power supplies include an LED in the rear with the following definitions 450 W and 650 W power supplies 450 W and 650 W power supply LEDs Solid green Power supply is o...

Page 13: ...setting If the server overheats do the following 1 Use the LEDs to determine the nature of the overheating condition 2 Confirm that the chassis covers are installed properly 3 Check the routing of the cables and make sure all fans are present and operating normally 4 Verify that the heatsinks are installed properly 2 3 5 DIVAR IP 6000 1U System overview en 13 Bosch Sicherheitssysteme GmbH Installa...

Page 14: ...s released from the locked position slide the cover toward the rear of the chassis 4 Lift the cover off the chassis Notice Except for short periods of time do NOT operate the server without the cover in place The chassis cover must be in place to allow proper airflow and prevent overheating Installing hard drives This chapter describes the removing and installing of hard drives Removing hard drive...

Page 15: ...e Except for short periods of time swapping hard drives do not operate the unit with the hard drives removed from the bays Installing a hard drive The drives are mounted in drive carriers To install a hard drive to the hard drive carrier 1 Remove the screws securing the dummy drive to the carrier 3 2 2 DIVAR IP 6000 1U Chassis setup and maintenance en 15 Bosch Sicherheitssysteme GmbH Installation ...

Page 16: ...oles align with those in the carrier 4 Secure the hard drive by tightening all 6 screws 1 Drive carrier 2 SAS SATA hard drive 5 Replace the drive carrier into the chassis bay Make sure that the drive carrier handle is completely closed 16 en Chassis setup and maintenance DIVAR IP 6000 1U 2014 01 V2 DOC Installation manual Bosch Sicherheitssysteme GmbH ...

Page 17: ...ne 4 If you are adding a new drive Remove the mini bezel grate from the drive bay The bezel can be removed by pulling out the hard drive beneath the DVD ROM or floppy drive bay then pulling the mini bezel forward If you are replacing a drive Locate the locking tab at the rear left hand side when viewed from the front of the DVD ROM or floppy drive Push the tab toward the drive and push the drive u...

Page 18: ...he fan side facing you hold the air shroud with your left hand on the main shroud component and right hand on the optional flap Gently twist with your right hand by lifting the fan side and lowering the other end of the optional flap 3 Place the air shroud in your chassis with the fan side touching the edge of the fans 4 Replace the chassis cover To check the air flow 1 Make sure there are no obje...

Page 19: ...ther objects away from the openings in the fan assembly s housing To add a system fan 1 Turn off the power to the system and unplug the system from the outlet 2 Remove the dummy fan from the fan tray 3 Place the new fan into the vacant space in the housing Make sure the arrows on the top of the fan indicating air direction point in the same direction as the arrows on the other fans 4 Connect the f...

Page 20: ... 7 Reconnect the power cord turn on the system and make sure that the fan is working properly before replacing the chassis cover Power supply The chassis has two redundant power supplies The power supplies are auto switching capable This enables the power supplies to automatically sense and operate at a 100 V to 240 V input voltage Warning Redundant power supplies This unit might have more than on...

Page 21: ...ly 2 Push the release tab on the back of the power supply 3 Pull the power supply out using the handle provided 4 Replace the failed power module with the same model 5 Push the new power supply module into the power bay until you hear a click 6 Plug the power cord back into the module and power up the server DIVAR IP 6000 1U Chassis setup and maintenance en 21 Bosch Sicherheitssysteme GmbH Install...

Page 22: ...setup location Situate the system in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Place the system near a grounded power outlet Leave approximately 25 inches clearance in front of the rack to be able to open the front door completely Leave approximately 30 inches of clearance in the back of the rack to allow for suf...

Page 23: ...d or multi unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature Tmra Reduced airflow Equipment should be mounted into a rack so that the amount of airflow required f...

Page 24: ... rack itself 1 Rail extension inner rail is pre installed on the chassis 2 Outer rails Installing the inner rails The chassis includes a set of inner rails which are in two sections inner rails and inner rail extensions The inner rails are pre attached and do not interfere with normal use of the chassis if you decide not to use a server rack Attach the inner rail extension to stabilize the chassis...

Page 25: ...ws as illustrated 4 Repeat steps for the other inner rail extension Assembling the outer rails To assemble the outer rails 1 Secure to the front of the rack 2 Attach the two sections of the outer rail together 3 Secure to the rear of the rack Installing the outer rails to the rack Outer rails attach to the rack and hold the chassis in place The outer rails extend between 30 inches and 33 inches 4 ...

Page 26: ... rack 2 Adjust both sections of the outer rail to the proper length so that the rail fits snugly within the rack 3 Secure the longer section of the outer rail to the front of the rack with two M5 screws and the shorter section to the rear side of the rack with two M5 screws 4 Repeat steps for the remaining outer rail See also Assembling the outer rails page 25 26 en Rack installation DIVAR IP 6000...

Page 27: ...has been pushed completely into the rack you should hear the locking tabs click 4 Optional Insert and tightening the thumbscrews that hold the front of the system to the rack Warning Do not pick up the unit with the front handles The handles are designed to pull the system from a rack only Warning Stability hazard Before sliding the unit out for servicing make sure that the rack stabilizing mechan...

Page 28: ...ositioned with just enough space to accommodate the width of the Telco rack Finish by sliding the chassis into the rack and tightening the brackets to the rack Turning on the system The last thing to be done is to provide input power to the system To turn on the system 1 Plug the power cord from the power supply unit into a high quality power strip that offers protection from electrical noise and ...

Page 29: ...ayout Figure 5 1 Motherboard layout Important notes to the user Jumpers not indicated are for testing only When LE2 Onboard Power LED Indicator is on system power is on Unplug the power cable before installing or removing any components All systems have a SATA DOM connected to Serial ATA ports I SATA 5 with a small power connector DOM PWR SATA DOM Is plugged in connector I SATA 5 on the motherboar...

Page 30: ...nabled 42 JBT1 CMOS Clear 40 JPES Energy Saving Feature Pins 2 3 Disabled 13 14 JI2C1 JI2C2 SMB to PCI Slots 17 JPG1 Onboard VGA Enable Pins 1 2 Enabled 11 12 JPL1 JPL2 LAN1 LAN2 Enable Pins 1 2 Enabled 24 JPT1 TPM Enable Pins 1 2 Enabled 10 JPB BMC Jumper Pins 1 2 Enabled 5 1 2 30 en Appendix DIVAR IP 6000 1U 2014 01 V2 DOC Installation manual Bosch Sicherheitssysteme GmbH ...

Page 31: ... 21 I SATA 0 5 Serial ATA ports X8SIL has 4 Serial ATA Ports 2 IPMI IPMI LAN Port X8SIL F Only 35 JPI2C PWR supply I2C System Management Bus 31 SPKR1 Internal speaker buzzer 25 T SGPIO 0 1 Serial General Purpose IO headers for SATA 3 20 USB0 1 Backplane USB 0 1 19 USB 4 Type A USB Connector 18 USB 10 11 Front Panel USB header X8SIL F Only 22 DOM PWR Disk On Module DOM Power Connector 39 JTPM Trust...

Page 32: ... Intel 82574L Gigabit 10 100 1000 Mb s Ethernet Controllers for LAN 1 and LAN 2 ports Two 2 RJ 45 Rear IO Panel Connectors with Link and Activity LEDs Single Realtek RTL8201N PHY to support IPMI 2 0 X8SIL F Only I O Devices SATA Connections X8SIL F X8SIL V Only SATA Ports Six 6 RAID Windows RAID 0 1 5 10 RAID Linux RAID 0 1 10 SATA Connections X8SIL Only SATA Ports Four 4 Integrated IPMI 2 0 X8SIL...

Page 33: ...wer on mode for AC power recovery PC Health Monitoring CPU Monitoring Onboard voltage monitors for CPU core 3 3V 5V 12V 3 3V Stdby 5V Stdby VBAT HT Memory Chipset CPU 3 Phase switching voltage regulator CPU System overheat LED and control CPU Thermal Trip support Thermal Monitor 2 TM2 support Fan Control Fan status monitoring with firmware 4 pin Pulse Width Modulation fan speed control Low noise f...

Page 34: ...onality and the capability of the single chip Intel 3400 chipset the X8SIL X8SIL F X8SIL V motherboard provides the performance and feature set required for single processor based systems with configuration options optimized for entry level server platforms The high speed Direct Media Interface DMI featured in the Intel 3400 3420 chipset enables the X8SIL X8SIL F X8SIL V motherboard to offer a hig...

Page 35: ...efine the sensitivity of the voltage monitor by using SD III Fan status monitor with software PC health monitoring can check the RPM status of the cooling fans via Supero Doctor III CPU overheat LED and control This feature is available when the user enables the CPU overheat warning feature in the BIOS This allows the user to define an overheat temperature When this temperature reaches this pre de...

Page 36: ... clock generator drive interface control logic and interrupt and DMA logic The wide range of functions integrated onto the Super I O greatly reduces the number of components required for interfacing with floppy disk drives The Super I O supports two 360 K 720 K 1 2 M 1 44 M or 2 88 M disk drives and data transfer rates of 250 Kb s 500 Kb s or 1 Mb s It also provides two high speed 16550 compatible...

Page 37: ...es One X Bus parallel interface for expansion I O connections Three ADC inputs Analog and Digital Video outputs Two serial for boundary scan and debug There are two different versions of the Nuvoton BMC chip that are used in this product series The Nuvoton WPCM150 Manufacturer P N WPCM150GA0BX5 which includes all of the features above is the chip installed in the X8SIL motherboard Another version ...

Page 38: ...tiple hardware damage exists If for example the RAID is deleted accidently eg with clear or new configuration instead of add and the configuration is set up exactly in disk order and stripesize the same as before the data area on the remaining operating system boots again without any problem This fact is useful when the RAID COD was lost for some reason but the disks are OK Multiple disks failed t...

Page 39: ...sk fails so no inconsistency can exist If you try to restore the RAID the first fail disk could be used for rebuild later or a new disk But the second failed disk must be used for hopefully get the offline RAID degraded again Two tools are useful to analyze what happened the Event Viewer in the Controller Bios Utility the MegaCLI a Command Line Utility How to use the Event Viewer in the Controller...

Page 40: ...oved PD 4 stops rebuilding Finally PD 4 is also removed The VD event reports first a degraded state then an offline state The first failed disk was the rebuilding PD4 When PD6 failed the rebuild stopped when PD4 was gone RAID gets offline 40 en Appendix DIVAR IP 6000 1U 2014 01 V2 DOC Installation manual Bosch Sicherheitssysteme GmbH ...

Page 41: ... GetEvents warning f warning txt aALL Adapter 0 Number of Events 288 seqNum 0x00001875 Time Mon Jul 19 13 37 28 2010 Code 0x00000124 Class 1 Locale 0x20 Event Description Patrol Read can t be started as PDs are either not ONLINE or are in a VD with an active process or are in an excluded VD Event Data None seqNum 0x0000188b Time Mon Jul 19 13 52 41 2010 Code 0x00000070 Class 1 Locale 0x02 Event De...

Page 42: ...000fb Class 2 Locale 0x01 Event Description VD 00 0 is now DEGRADED Event Data Target Id 0 seqNum 0x000018bc Time Mon Jul 19 14 12 25 2010 Code 0x000000fb Class 2 Locale 0x01 Event Description VD 01 1 is now DEGRADED Event Data Target Id 1 Useful commands MegaCli AdpEventLog GetEvents info f info txt aALL but a large text file MegaCli AdpEventLog GetEvents fatal f fatal txt aALL 42 en Appendix DIV...

Page 43: ...891 Time Mon Jul 19 13 52 41 2010 Code 0x000000fc Class 3 Locale 0x01 Event Description VD 01 1 is now OFFLINE Event Data Target Id 1 Multiple disks failed practice Press C to enter Utility Click start and scan disks You get to the foreign configuration import screen Select one of the two configurations and click Preview 5 9 2 DIVAR IP 6000 1U Appendix en 43 Bosch Sicherheitssysteme GmbH Installat...

Page 44: ...a complex situation requires manual interaction Click to clear all configurations ignore the warning Before clear foreign configuration 2 disks were missing two were foreign After clear the foreign disks now are shown as unconfigured 44 en Appendix DIVAR IP 6000 1U 2014 01 V2 DOC Installation manual Bosch Sicherheitssysteme GmbH ...

Page 45: ... Logical View and you get in the Physical drive menu Choose replace missing PD and the correct row for Slot 7 drive and click go Ignore the warning Now in Logical View we see this disk marked as offline click on the disk to get in PD menu Click on Make online and go DIVAR IP 6000 1U Appendix en 45 Bosch Sicherheitssysteme GmbH Installation manual 2014 01 V2 DOC ...

Page 46: ...ogical View the rebuild is starting Foreign configuration disk appears in the Windows GUI after booting The RAID is degraded Topology error is shown Right click Megaraid Controller in the MSM GUI Click scan foreign configuration In the next window click clear foreign configuration 5 9 3 46 en Appendix DIVAR IP 6000 1U 2014 01 V2 DOC Installation manual Bosch Sicherheitssysteme GmbH ...

Page 47: ...oose a hotspare type You see the rebuild is starting at once MegaCLI Commandline Utility Silent AppLogFile filename NoLog page N is optional N Number of lines per page 5 9 4 DIVAR IP 6000 1U Appendix en 47 Bosch Sicherheitssysteme GmbH Installation manual 2014 01 V2 DOC ...

Page 48: ...op EnableJBOD val aN a0 1 2 aALL val 0 Disable JBOD mode 1 Enable JBOD mode MegaCli AdpSetProp DsblCacheBypass val aN a0 1 2 aALL val 0 Enable Cache Bypass 1 Disable Cache Bypass MegaCli AdpSetProp LoadBalanceMode val aN a0 1 2 aALL val 0 Auto Load balance mode 1 Disable Load balance mode MegaCli AdpSetProp UseFDEOnlyEncrypt val aN a0 1 2 aALL val 0 FDE and controller encryption if HW supports is ...

Page 49: ...pDiag val aN a0 1 2 aALL val Time in second MegaCli AdpBatTest aN a0 1 2 aALL MegaCli PDList aN a0 1 2 aALL MegaCli PDGetNum aN a0 1 2 aALL MegaCli pdInfo PhysDrv E0 S0 E1 S1 aN a0 1 2 aALL MegaCli PDOnline PhysDrv E0 S0 E1 S1 aN a0 1 2 aALL MegaCli PDOffline PhysDrv E0 S0 E1 S1 aN a0 1 2 aALL MegaCli PDMakeGood PhysDrv E0 S0 E1 S1 Force aN a0 1 2 aALL MegaCli PDMakeJBOD PhysDrv E0 S0 E1 S1 aN a0 ...

Page 50: ...SscdDel LX L0 2 5 LALL aN a0 1 2 aALL MegaCli CfgFreeSpaceinfo aN a0 1 2 aALL MegaCli CfgSpanAdd r10 Array0 E0 S0 E1 S1 Array1 E0 S0 E1 S1 ArrayX E0 S0 E1 S1 aN MegaCli CfgSpanAdd r50 Array0 E0 S0 E1 S1 E2 S2 Array1 E0 S0 E1 S1 E2 S2 ArrayX E0 S0 E1 S1 E2 S2 WT WB NORA RA ADRA Direct Cached CachedBadBBU NoCachedBadBBU strpszM szXXX szYYY AfterLdX FDE CtrlBased aN MegaCli CfgAllFreeDrv rX SATAOnly ...

Page 51: ...aN a0 1 2 aALL MegaCli ShowVpd Page N Encl N aN a0 1 2 aALL MegaCli EnclLocate Start Stop Encl N aN a0 1 2 aALL MegaCli EnclFwDownload Encl N Esm A B f filename aN a0 1 2 aALL MegaCli PdFwDownload SataBridge PhysDrv 0 1 1 2 f filename aN a0 1 2 aALL MegaCli SetFacDefault Encl N Esm A B f filename aN a0 1 2 aALL MegaCli PDCpyBk Start PhysDrv E0 S0 E1 S1 aN a0 1 2 aALL MegaCli PDCpyBk Stop ShowProg ...

Page 52: ...ename aN Note The directly connected drives can be specified as S Wildcard can be used to specify the enclosure ID for the drive in the only enclosure without direct connected device or the direct connected drives with no enclosure in the system Note aALL option assumes that the parameters specified are valid for all the Adapters The following options may be given at the end of any command above S...

Page 53: ......

Page 54: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2014 ...

Reviews: