28
en | Quick set-up
Dinion IP
V 2.5 | 2007.6
Operating Instructions
Bosch Security Systems
–
Use the up or down keys to scroll up or down through a
menu.
–
Use the left or right keys to move through options or to set
parameters.
–
When in a menu, quickly pressing the menu/select key
twice restores the selected item to its factory default.
–
To close all menus at once from any menu, select the
Exit
item and hold down the menu/select key until the menu
display disappears.
4.2.2
Install menu
Install lens wizard submenu
4.3
Adjustment procedure DC-iris Lens
1.
Unlock the back focus locking button.
2.
Access the
Lens Wizard
menu.
3.
Set Back Focus Now
is highlighted in the menu.
Function
Selection
Description
Lens Wizard
Select submenu
Select to optimize camera lens combination
Network
Select submenu
Select to set the network IP address for the cam-
era (default address is 192.168.0.1)
Exit
Exit the menu
Function
Selection
Description
Lens Type
AUTO, MANUAL,
DCIRIS, VIDEO
In AUTO mode the camera auto detects the type of
lens used or force the camera into a mode.
Detected
If the LENS TYPE detection is in AUTO, the
detected lens type is shown.
Set Back
Focus Now
Select to force lens to its maximum opening. After
focusing the lens the object of interest remains in
focus in bright and low light conditions.
Set LVL
(Video iris lenses only). The level detector indica-
tor must be set to the center by adjusting the level
potentiometer on the lens, to obtain the best pic-
ture performance.
Exit
Return to the INSTALL menu