en
Cleaning and maintenance
12
Installing the metal mesh grease filter
:
Warning
Risk of injury!
Components inside the appliance may have sharp
edges. Wear protective gloves.
Notes
■
Clean all accessible parts of the housing.
■
Clean the appliance support cables with care.
1.
Insert the metal grease filter. When you do this, take
hold of the metal grease filter from underneath with
your other hand.
Note:
Make sure that the metal grease filter is
positioned correctly.
2.
Swing the metal grease filter up and click it into
place.
3.
If the metal grease filter has not been inserted
correctly, open the lock and reinsert the metal
grease filter correctly.
Replacing the activated charcoal filter
Note:
To bind odours in circulating-air mode, you must
install an activated carbon filter. The different options for
operating the appliance in circulating-air mode can be
found in the brochure. Alternatively, ask your dealer.
The required accessories are available from specialist
retailers, from customer service or from the Online
Shop.
1.
Open the cover on the top of the appliance.
2.
Remove the old activated charcoal filter and insert
the new one.
3.
Close the cover.
4.
Reset the saturation indicator.
~
"Saturation display"
on page 6