Incorrect repairs are dangerous.

Repairs to the appliance should only be
carried out by trained specialist staff.

Only use genuine spare parts when repair-
ing the appliance.

If the power cord of this appliance is dam-
aged, it must be replaced by the manufac-
turer, the manufacturer's Customer Service
or a similarly qualified person in order to
prevent any risk.

Incorrect installation is dangerous.

Connect and operate the appliance only in
accordance with the specifications on the
rating plate.

Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.

The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.

Never equip the appliance with an external
switching device, e.g. a timer or remote
control.

When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.

When installing the appliance, check that
the power cable is not trapped or dam-
aged.

11.5 General information

Follow these general instructions during the installation.

¡

For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.

¡

When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.

¡

In order to freely access the appliance for servicing,
select an easy-to-reach installation site.

¡

The surfaces of the appliance are sensitive. Avoid
damaging them during installation.

11.6 Information on the installation situation

¡

Install this appliance in a kitchen cupboard.

¡

To install additional special accessory parts, ob-
serve the enclosed installation instructions.

¡

The width of the extractor hood must correspond at
least with the width of the hob.

¡

To optimally detect the cooking vapours, install the
appliance in the middle of the hob.

11.7 Instructions for the electrical
connection

In order to safely connect the appliance to the elec-
trical system, follow these instructions.

WARNING ‒ Risk of electric shock!

It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.

The mains plug for the mains power cable must be
easily accessible after the appliance is installed.

If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.

The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.

Sharp-edged components inside the appliance may
damage the connecting cable.

Do not kink or trap the connecting cable.

¡

The connection data can be found on the rating
plate. → 

Page 9

¡

The connecting cable is approx. 1.30 m long.

¡

This appliance complies with the EC interference
suppression regulations.

¡

The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.

¡

Do not connect the appliance to the power supply
during installation.

¡

Ensure that the protection against contact is guaran-
teed during installation.

11.8 Instructions for the exhaust air pipe

The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.

¡

Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.

¡

Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.

¡

Use an exhaust pipe that is made of non-combust-
ible material.

¡

To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.

Round pipes

Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.

11.9 Instructions for the air extraction mode

For air extraction mode, a one-way flap should be in-
stalled.

Notes

¡

If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.

¡

If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.

Summary of Contents for DFT60BC24

Page 1: ...Register your new device on MyBosch now and get free benefits bosch home com welcome Extractor hood DFT60BC24 en User manual and installation instructions ...

Page 2: ...ation Only use this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up to an altitude of max 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical sensory or mental abilities or inad equate experi...

Page 3: ...grease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters regularly Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a solid fuel heating appliance e g wood or coal burning unless the heating appliance has a sealed non removable cover There must be no flying sparks Hot oil or grease ignites very qui...

Page 4: ...ghly acidic cleaning agents In particular do not use commercial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters regularly WARNING Risk of injury Improper repairs are dangerous Repairs to the appliance should only be carried out by trained speciali...

Page 5: ...Put the cooking lid on The cooking vapours and condensation are re duced Only use the additional functions if required Switching off additional functions reduces power consumption 4 Operating modes 4 1 Air extraction mode The air which is drawn in is cleaned by the grease fil ters and conveyed to the exterior by a pipe system The air must not be discharged into a flue that is used for exhausting f...

Page 6: ...ive detergents Do not use cleaning products with a high alcohol content Do not use hard scouring pads or cleaning sponges Do not use any special cleaners for cleaning the ap pliance while it is hot Only use glass cleaners glass scrapers or stainless steel care products if recommended in the cleaning instructions for the relevant part Wash sponge cloths thoroughly before use 7 2 Cleaning the applia...

Page 7: ...emoval WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters roughly every 2 months Requirement The grease filters have been removed Removing the grease filter Page 7 1 Observe the information regarding the cleaning agents 2 Soak the grease filter in hot soapy water Use special grease solvent for stubborn dirt You can obtain grease solvents from after sa...

Page 8: ...n call after sales service 9 Disposal 9 1 Disposing of old appliance Valuable raw materials can be reused by recycling 1 Unplug the appliance from the mains 2 Cut through the power cord 3 Dispose of the appliance in an environmentally friendly manner Information about current disposal methods are available from your specialist dealer or local author ity This appliance is labelled in accord ance wi...

Page 9: ... clearances Comply with the safety clearances for the appliance 11 4 Secure installation Follow these safety instructions when in stalling the appliance WARNING Risk of poisoning Risk of poisoning from flue gases being drawn back in Room air dependent heat pro ducing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in...

Page 10: ...in it and suffocate Keep packaging material away from chil dren Do not let children play with packaging ma terial WARNING Risk of fire Grease deposits in the grease filter may catch fire The specified safety clearances must be complied with in order to prevent a build up of heat Observe the specifications for your cooking appliances If the installation instructions for the cooking appliances speci...

Page 11: ...tions for the electrical connection In order to safely connect the appliance to the elec trical system follow these instructions WARNING Risk of electric shock It must always be possible to disconnect the appliance from the electricity supply The appliance must only be connected to a protective contact socket that has been correctly installed The mains plug for the mains power cable must be easily...

Page 12: ... 102 83 2 When installing with an intermediate floor slightly screw the mounting brackets onto the appliance In sert the appliance into the opening in the intermedi ate floor Mark the holes for the mounting brackets on the side walls Unscrew the mounting brackets from the appliance again 3 Screw the mounting brackets to the unit In doing so only tighten the screws tight enough that the mounting br...

Page 13: ...correct posi tion when refitting the reducing disc Measuring the airflow In order to measure the pressure drop attach the hose to the measurement opening on the front edge of the air pipe connector Removing the appliance 1 Disconnect the appliance from the power supply 2 Loosen the exhaust pipe 3 Remove the grease filters To avoid causing damage do not bend the grease filters 4 Loosen the screw co...

Page 14: ...rced ventilation adjustment diagram Static pressure drop pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA Cut away rings Existing opening of the reducing disc Without reducing disc Airflow K1 K2 K3 K4 K5 K factor 2 41 2 82 3 24 3 76 4 31 ...

Page 15: ...iagram Static pressure drop pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA Setting Airflow K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11 K12 K factor 0 46 0 57 0 70 0 80 0 92 1 04 1 13 1 20 1 36 1 46 1 60 1 71 ...

Page 16: ...e Free and easy registration also on mobile phones www bosch home com welcome Looking for help You ll find it here Expert advice for your Bosch home appliances help with problems or a repair from Bosch experts Find out everything about the many ways Bosch can support you www bosch home com service Contact data of all countries are listed in the attached service directory 9001578322 9001578322 0209...