36
en | Installation material and tools
DICENTIS
2021.01 | V2.2 |
Hardware Installation Manual
Bosch Security Systems B.V.
5.
Close the housing and fix the screw with torque 0.4 Nm.
Note:
–
Requirements for the power supply:
–
nominal output of 48 VDC (ranging from 47 - 49 VDC)
–
the ripple should be less than 200 mV pk-pk
–
maximum output current should not exceed 3.0 A (or limited to 3.0 A, because
DICENTIS cables and devices have a maximum rating for this current)
–
Advice
–
It is strongly advised that the power supply has its own short circuit protection with
a short circuit output current ranging from 4.3 to 5.0 A.
–
When the power supply has an automatic restart after a short circuit, this restart
function should have an interval time of 3 to 4 seconds and should have no more
than 4 restart attempts.
–
Upon powering off the power supply, the output should be less than 9 V, 1 mA.
–
The maximum distance between the (A)PS and the conference device is limited to 100 m
due to the Ethernet properties.
P
+
-
Figure 5.5:
Transporting the power via cable
Figure 5.6:
Creating a tension relief, tie wrap prevents the power cables from being pulled out accidentally.
5.1.5
Using a cable coupler to switch the system on
The DICENTIS system automatically goes into “standby” mode when:
–
the option to automatically switch off the system after a period of inactivity is configured
in the Meeting Application, and
Summary of Contents for DCNM-APS2