D9131A
Event Description and Troubleshooting
D9131A User's Guide
34584G
Page 6
© 2002 Bosch Security Systems
Event
Description
Fire
Supervision
Supervision condition at the fire point specified.
Fire
Supervision
Restoral
Supervision condition at the fire point specified has been restored.
Fire Trouble
Trouble condition at area device specified.
Fire Walk End
Walk test* for fire devices in the area specified is complete.
Fire Walk Start
A walk test* is in progress for fire devices in the area specified.
Forced Close
User with reported ID armed area with point(s) faulted.
Forced Point
User force armed device in area reported.
Late To Close
User with reported ID armed the security system later than expected.
Late To Open
User with the reported ID disarmed area later than expected. If the entire security system is
being disarmed, the previous state of the system is indicated. If just one area is being
disarmed, no previous state is indicated.
Log Overflow
Security system event log is full. Events are being overwritten.
Log Threshold
Security system event log is at the programmed maximum capacity.
Missing Alarm
Device in area specified is not reporting. Call for service.
Missing Fire
Fire device in area specified is not reporting. Call for service.
Missing Trouble
Trouble Condition at area device specified.
Msng
Supervision
Supervision device at area specified is not reporting.
No Entry -
Level
An access card holder attempted access but was denied due to the user’s authority level.
No Entry -
Interlk
Access was denied due to the interlock door being open.
No Entry -
Secured
Access was denied due to the door being secured.
No Entry -
Unknown
Access was denied because the user was not found in the database.
Opening Report
User with reported ID disarmed area.
Params Changed
Security system programming has been changed.
Peri Dlay Armed
User with ID reported armed the perimeter of the specified area with delay time.
Peri Inst Armed
User with reported ID armed the perimeter of the specified area with no delay time.
Phone Line Fail
The phone line specified is not working. Call for service.
Phone Restoral
The problem with the phone line specified has been restored.
Point Bypass
Area device specified is bypassed.* System will not respond to faults at this device.
Point Closing
User armed device in area specified.
Point Opening
User disarmed device in area specified.
Point Status
Status report for device in area specified.
Point Tested
This device has been walk tested.*
Prog Access Ok
Account has been accessed locally by the device specified.
Pt Bus Trouble
Wiring problem. Call for service.
Pt Bus Restoral
Wiring problem is resolved.
Ram Access Fail
Technician could not access your security system from the security company.
Ram Access Ok
Your security company accessed your system from the security company.
Re-Boot
Your security system was reset.
Relay Reset
Relay has reset.
Relay Set
Relay specified has been turned on.
Request To
A Request To Enter device for an access door has been activated.