D9131A

Event Description and Troubleshooting

 D9131A User's Guide 

34584G

Page 6

© 2002 Bosch Security Systems

Event

Description

Fire
Supervision

Supervision condition at the fire point specified.

Fire
Supervision
Restoral

Supervision condition at the fire point specified has been restored.

Fire Trouble

Trouble condition at area device specified.

Fire Walk End

Walk test* for fire devices in the area specified is complete.

Fire Walk Start

A walk test* is in progress for fire devices in the area specified.

Forced Close

User with reported ID armed area with point(s) faulted.

Forced Point

User force armed device in area reported.

Late To Close

User with reported ID armed the security system later than expected.

Late To Open

User with the reported ID disarmed area later than expected. If the entire security system is
being disarmed, the previous state of the system is indicated. If just one area is being
disarmed, no previous state is indicated.

Log Overflow

Security system event log is full. Events are being overwritten.

Log Threshold

Security system event log is at the programmed maximum capacity.

Missing Alarm

Device in area specified is not reporting. Call for service.

Missing Fire

Fire device in area specified is not reporting. Call for service.

Missing Trouble

Trouble Condition at area device specified.

Msng
Supervision

Supervision device at area specified is not reporting.

No Entry -
Level

An access card holder attempted access but was denied due to the user’s authority level.

No Entry -
Interlk

Access was denied due to the interlock door being open.

No Entry -
Secured

Access was denied due to the door being secured.

No Entry -
Unknown

Access was denied because the user was not found in the database.

Opening Report

User with reported ID disarmed area.

Params Changed

Security system programming has been changed.

Peri Dlay Armed

User with ID reported armed the perimeter of the specified area with delay time.

Peri Inst Armed

User with reported ID armed the perimeter of the specified area with no delay time.

Phone Line Fail

The phone line specified is not working. Call for service.

Phone Restoral

The problem with the phone line specified has been restored.

Point Bypass

Area device specified is bypassed.* System will not respond to faults at this device.

Point Closing

User armed device in area specified.

Point Opening

User disarmed device in area specified.

Point Status

Status report for device in area specified.

Point Tested

This device has been walk tested.*

Prog Access Ok

Account has been accessed locally by the device specified.

Pt Bus Trouble

Wiring problem. Call for service.

Pt Bus Restoral

Wiring problem is resolved.

Ram Access Fail

Technician could not access your security system from the security company.

Ram Access Ok

Your security company accessed your system from the security company.

Re-Boot

Your security system was reset.

Relay Reset

Relay has reset.

Relay Set

Relay specified has been turned on.

Request To

A Request To Enter device for an access door has been activated.

Summary of Contents for D9131A

Page 1: ...Parallel Printer Interface Module D9131A User s Guide ...

Page 2: ...D9131A D9131A User s Guide 34584G Page 2 2002 Bosch Security Systems ...

Page 3: ... a Print Log command that allows you to print the entire history of events stored in your system or you may select to print only events that have occurred from a specific date forward 1 3 Printing Format Your security system prints events with top and bottom margins and form feed between pages with descriptive headers Each event is printed on two lines The first line contains the time and date the...

Page 4: ...1 through 8 indicate the event is from one of the supervised command centers The numbers 17 18 or 19 indicate the event is from a printer Numbers 33 to 40 indicate the event is from the Access Control Module The following text indicates previous armed status Was Master Armed Was Perim Delay Was Perim Instant Was Disarmed Was Mstr Instnt User Text Your alarm technician usually will program this Use...

Page 5: ...ted Closing Report User with reported ID armed area Comm Failure Security system could not communicate using the phone number reported Call for service Date Changed User with reported ID changed the date in the security system Door Closed Restoral An access door in the area specified restored to normal after a Door Left Open event has occurred Door Cycled An access door in the area specified was c...

Page 6: ...An access card holder attempted access but was denied due to the user s authority level No Entry Interlk Access was denied due to the interlock door being open No Entry Secured Access was denied due to the door being secured No Entry Unknown Access was denied because the user was not found in the database Opening Report User with reported ID disarmed area Params Changed Security system programming...

Page 7: ...s report opening at area specified S Perim Delay Status report area perimeter specified is armed with entry exit delay S Perim Instant Status report area perimeter specified is armed no delay S Supervision Status report Supervision at area specified S Trouble Status report trouble at area specified SDI Failure Serial Device Interface specified is not reporting 1 8 command centers 017 018 019 print...

Page 8: ...al alarm in the area specified Usr Code Change User ID specified was changed Usr Code Delete User ID specified was deleted User Level Set The authority level of the specified user has been modified User Tamper User with wrong ID tried to access specified area Walk End Walk test in area specified is complete Walk Start A walk test is in progress in the area specified Was Force Armed User with the r...