background image

16/18 

Bosch Rexroth Canada ı 07.22.2013 ı Revision 2.0

 

Warning Messages 

Suggested Solution 

UNLOAD NOT ALLOWED     

21 

Vehicle needs to be stationary 

BB3 SYSTEM ERROR 

22 

Check if RCE present, Reboot 

RC COMMUNICATION ERROR 

23 

Comm failure between display and RC 

RCE  COMMUNICATION ERROR 

24 

Comm failure between RC and RCE 

JOY 1  COMMUNICATION ERROR 

25 

Comm failure between RC and Joystick 1 

JOY 2  COMMUNICATION ERROR 

26 

Comm failure between RC and Joystick 2 

NO GATE SENSOR 

27 

Check gate sensor, cable break 

GATE POSITION ZERO 

28 

Gate closed in READBACK mode 

NO GROUND SPEED SIMULATION 

29 

Speed Simulation mode stopped 

UNDER APPLICATION-SPINNER 

30 

Spinner not able to reach desired RPM 

UNDER APPLICATION-CONVEYOR 

31 

Rate or speed too high, incorrect calibration 

UNDER APPLICATION-PREWET 

32 

Rate or speed too high, incorrect calibration 

UNDER APPLICATION-ANTI-ICING 

33 

Rate or speed too high, incorrect calibration 

OVER APPLICATION-COVEYOR 

34 

Min null or gate too high,  

OVER APPLICATION-PREWET 

35 

Min null too high, rate too low 

OVER APPLICATION-ANTI-ICING 

36 

Min null too high, rate too low 

CALIB:GND SPD PULSES  TOO LOW 

37 

Too few or no pulses, recalibrate 

SPINNER MAX RPM TOO LOW 

38 

Bad or no sensor 

CONVEYOR MAX RPM TOO LOW 

39 

Bad or no sensor 

PREWET MAX HZ TOO LOW 

40 

Too few pulses, or sensor failed 

ANTI_ICING MAX HZ TOO LOW 

41 

Too few pulses, or sensor failed 

WRONG SPINNER CONTROL MODE 

42 

Auto null not allowed for MANUAL mode 

SPARE 

43 

Not used 

WRONG PREWET CONTROL MODE 

44 

Auto-null or volume calibration not allowed  

WRONG ANTI-ICING CONTROL MODE  45 

Check Anti-icing or Cross-Conv modes 

WRONG CROSS-CONVEYOR MODE 

46 

Check Cross-Conv mode setting 

WT/REV TOO LOW 

47 

Check conveyor sensor, and calibrate again 

WT/REV TOO HIGH 

48 

Check conveyor sensor, and calibrate again 

PREWET PULSES/GAL TOO LOW 

49 

Check prewet sensor, and calibrate again 

PREWET PULSES/GAL TOO HIGH 

50 

Check prewet sensor, and calibrate again 

ANTI-ICING PULSES/GAL TOO LOW 

51 

Check anti-icing sensor, and calibrate again 

Summary of Contents for CS 150 RC

Page 1: ...CS 550 150RC Spreader Joystick Controller Operator Manual ...

Page 2: ...ystick Control Joystick Control Joystick Control 1 1 1 11 1 1 1 5 1 Button Status 11 5 2 Joystick Status 11 5 3 Joystick Screen 11 6 6 6 6 Anti Anti Anti Anti ice Mode ice Mode ice Mode ice Mode 1 1 1 12 2 2 2 7 7 7 7 Pattern Mode Pattern Mode Pattern Mode Pattern Mode 1 1 1 13 3 3 3 8 8 8 8 Air Gate Air Gate Air Gate Air Gate Mode Mode Mode Mode 1 1 1 13 3 3 3 9 9 9 9 Liquid Liquid Liquid Liquid ...

Page 3: ...3 18 Bosch Rexroth Canada ı 07 22 2013 ı Revision 2 0 1 Panel Controls Turn knobs clockwise to increase ...

Page 4: ...Program Screen Layout SPNR SALT LIQUID1 Spinner Label Spread Width Spinner Setpoint Spinner Mode Pause Button Solid Name Gate Mode Solid Rate Gate Position Conv Set Conveyor Mode Blast Button Liquid Name Liquid Rate Liquid Setpoint Liquid Mode Reverse Button ...

Page 5: ...use and press again to resume spreading 3 2 Blast Press the Blast button to increase the spreading output and press again to resume regular rate 3 3 Reverse Press and hold the Reverse button to change the direction of the Auger an optional feature to dislodge obstructions Release the button to resume spreading ...

Page 6: ...ress the oval button again to confirm and save the selection 3 5 Change Liquid Material Press the oval button with the LIQUID1 text to adjust the material type Note vehicle must be stationary Use the Left and Right arrows to adjust Press the oval button again to confirm and save the selection 3 6 Manual Gate Adjustment For Manual Gate operation ONLY Press the Gate Position Number to select the gat...

Page 7: ... 4 Symbol Actions All symbols on the right of the screen require a press and hold for 1 seconds 4 4 4 4 1 1 1 1 Error Error Error Error Log Log Log Log Diagnostic Diagnostic Diagnostic Diagnostic When the vehicle is stationary press the Gear Gear Gear Gear symbol to display most recent error messages If a hydraulic pressure temperature sensor is connected both readings will be displayed on the bot...

Page 8: ...vehicle is moving press the Gear Gear Gear Gear symbol to display the real time status of spreading 4 4 4 4 2 UNLO 2 UNLO 2 UNLO 2 UNLOAD AD AD ADING ING ING ING Press the Unload Unload Unload Unload symbol to enter into unload mode Note The vehicle must be stationary Turn the dials until the desired speed is achieved Press the symbol again ...

Page 9: ... PROGRAMMING KEY PROGRAMMING KEY PROGRAMMING KEY PROGRAMMING KEY inserted inserted inserted inserted Press the USB USB USB USB symbol to transfer the log data and the parameter Transfer Successful will appear on the screen momentarily when it finishes Without a key inserted Without a key inserted Without a key inserted Without a key inserted Press the USB USB USB USB symbol to clear trip summary N...

Page 10: ...the Cylinder Cylinder Cylinder Cylinder symbol to select the gate adjustment mode Use the up and down arrows to adjust Press the Cylinder Cylinder Cylinder Cylinder symbol again to end the gate adjustment 4 6 Programming Mode Press the Lock Lock Lock Lock symbol to enter into programming mode Note A valid PROGRAMMING KEY must be inserted into the USB port See Calibration Manual for programming det...

Page 11: ...rrow symbols represent the direction the joystick handle is being deflected The mode status is displayed in the top right of both spreader and joystick screens 5 3 Joystick Screen Available only when equipped with a CS 150 Armrest Console Screen flips when the Deadman Trigger is pressed When the trigger is released the screen reverts back to the spreader layout Note The joystick will only operate ...

Page 12: ...ess the oval buttons to select the desired boom Pause and Blast operate the same as a Granular Spreader Rate Selection Rate Selection Rate Selection Rate Selection Use the dial on the right to select the desired liquid flow rate The reverse button is de activated 6 2 Single Boom Use the upper right arrows to select the desired liquid flow rate ...

Page 13: ...s Note To calibrate the centre position you would need to click on the symmetry reading while a program key is inserted 8 Air Gate Mode Use the controls on the top right of the screen to control the Air Gate When vehicle is stationary click on left or right button to toggle between two materials and automatically set the operation gate to the calibrated gate for the material selected ...

Page 14: ...d Blast operate the same as a Granular Spreader Rate Selection Rate Selection Rate Selection Rate Selection Use the upper right arrows to select the desired liquid flow rate Solid and Pre Solid and Pre Solid and Pre Solid and Pre wet wet wet wet All standard spreader functions perform as defined earlier in the manual 10 Cross Conveyor Mode Use the controls on the top right of the screen to control...

Page 15: ...BLAST TOO LONG 1 Turn off blast reset timer ERROR DEICE BLST TOO LONG 2 Turn off blast reset timer ERROR OVERSPEED 3 Slow down reset max speed ERROR SPIN PROP 4 Check cables replace coil ERROR CONV PROP 5 Check cables replace coil ERROR CROSS1 PROP 6 Check cables replace coil ERROR CROSS2 PROP 7 Check cables replace coil ERROR NO MATL DETECT 8 Load material check sensor ERROR NO LIQ DETECT 9 Load ...

Page 16: ...ect calibration OVER APPLICATION COVEYOR 34 Min null or gate too high OVER APPLICATION PREWET 35 Min null too high rate too low OVER APPLICATION ANTI ICING 36 Min null too high rate too low CALIB GND SPD PULSES TOO LOW 37 Too few or no pulses recalibrate SPINNER MAX RPM TOO LOW 38 Bad or no sensor CONVEYOR MAX RPM TOO LOW 39 Bad or no sensor PREWET MAX HZ TOO LOW 40 Too few pulses or sensor failed...

Page 17: ...w SPINNER OUTPUT RANGE TOO LOW 60 Range between spn Min and Max too small CONV OUTPUT RANGE TOO LOW 61 Range between Conv Min and Max too small CROS CONV1 OUTPUT RANGE LOW 62 Range between Cros1 Min and Max too small CROS CONV2 OUTPUT RANGE LOW 63 Range between Cros1 Min and Max too small PREWET OUTPUT RANGE LOW 64 Range between prewet Min and Max too small ANTI ICING OUTPUT RANGE LOW 65 Range for...

Page 18: ...ak if the display is dropped on to a hard surface or receives a substantial impact If the glass chips or cracks discontinue use and contact Bosch Rexroth Canada to have it replaced do not touch or attempt to remove the broken glass Any misuse abuse causing damage whether intended or not will become the sole responsibility of the owner buyer which will render the warranty of this product void Notes...