
Information about the appliance
25
Greenstar FS/Combi FS – 6 720 810 590 (2020/04)
3.18
Technical data combi boiler KWB 42-3
Input / Output
Unit
NG
LPG (Propane)
Max. input rate 180/79 °F (82/26 °C)
BTU/hr (kW)
151,600 (44.4)
148,300 (43.5)
Max. output rate 104/86 °F (40/20 °C)
BTU/hr (kW)
137,500 (40.3)
137,500 (40.3)
Max. output rate 122/86 °F (50/30 °C)
BTU/hr (kW)
137,500 (40.3)
137,500 (40.3)
Max. output rate 176/140 °F (80/60 °C)
BTU/hr (kW)
134,400 (39.4)
134,400 (39.4)
Output rate domestic hot water (DHW) 113 °F (45 °C)
BTU/hr (kW)
137,500 (40.3)
137,500 (40.3)
Output rate domestic hot water (DHW) 140 °F (60 °C)
BTU/hr (kW)
135,800 (39.8)
135,800 (39.8)
Max. input rate 180/79 °F (82/26 °C)
BTU/hr (kW)
36,000 (10.5)
46,400 (13.6)
Max. output rate 104/86 °F (40/20 °C)
BTU/hr (kW)
35,500 (10.4)
46,400 (13.6)
Max. output rate 122/86 °F (50/30 °C)
BTU/hr (kW)
35,100 (10.3)
46,100 (13.5)
Max. output rate 176/140 °F (80/60 °C)
BTU/hr (kW)
31,700 (9.3)
42,000 (12.3)
Input / Output at elevation 2000 - 4500 feet (611 - 1372 metres)
Max. input rate 180/79 °F (82/26 °C)
BTU/hr (kW)
136,440 (40.0)
139,402 (40.9)
Max. output rate 104/86 °F (40/20 °C)
BTU/hr (kW)
123,750 (36.3)
129,250 (37.9)
Max. output rate 122/86 °F (50/30 °C)
BTU/hr (kW)
123,750 (36.3)
129,250 (37.9)
Max. output rate 176/140 °F (80/60 °C)
BTU/hr (kW)
120,960 (35.3)
126,336 (37.0)
Output rate domestic hot water (DHW) 113 °F (45 °C)
BTU/hr (kW)
123,750 (36.3)
129,750 (37.9)
Output rate domestic hot water (DHW) 140 °F (60 °C)
BTU/hr (kW)
122,220 (35.8)
127,652 (37.4)
Input / Output at elevation 4500 - 7000 feet (1373 - 2143 metres)
Max. input rate 180/79 °F (82/26 °C)
BTU/hr (kW)
125,828 (36.9)
129,021 (37.8)
Max. output rate 104/86 °F (40/20 °C)
BTU/hr (kW)
114,125 (33.5)
119,625 (35.1)
Max. output rate 122/86 °F (50/30 °C)
BTU/hr (kW)
114,125 (33.3)
119,625 (35.1)
Max. output rate 176/140 °F (80/60 °C)
BTU/hr (kW)
111,552 (32.7)
116,928 (34.3)
Output rate domestic hot water (DHW) 113 °F (45 °C)
BTU/hr (kW)
114,125 (33.5)
129,750 (37.9)
Output rate domestic hot water (DHW) 140 °F (60 °C)
BTU/hr (kW)
112,714 (33.0)
127,652 (37.4)
Gas connection value
Natural gas - H
s
=1,010 BTU/ft
3
(37.3MJ/m
3
)
ft
3
/hr (m
3
/h)
149 (4.2)
-
Liquid Propane Gas - HD-S = 2,500 BTU/ft
3
(37.3MJ/m
3
)
ft
3
/hr (m
3
/h)
-
59 (1.7)
Permissible gas inlet pressure
NG
in. W.C. (mbar)
3.5 - 10.5” (8.7-26.1)
-
LPG (Propane)
in. W.C. (mbar)
-
8-13” (19.9-32.3)
Expansion vessel
Pre-charge pressure
psi (bar)
10.9 (0.75)
10.9 (0.75)
Total contents
Gallon (litre)
3.17 (12)
3.17 (12)
DHW
Maximum DHW flow rate
gpm (litres/min.)
3.963 (15)
3.963 (15)
Nominal DHW flow rate (at 140 °F (60 °C) outlet temperature)
gpm (litres/min.)
3.61 (11.4)
3.61 (11.4)
Outlet temperature
°F ( °C)
104 - 140 (40 - 60)
104 - 140 (40 - 60)
Maximum cold water inlet temperature
°F ( °C)
140 (60)
140 (60)
Maximum approved DHW pressure
psi (bar)
150 (10.3)
150 (10.3)
Minimum water pressure
psi (bar)
4.35 (0.3)
4.35 (0.3)
Flue gas
Flue gas mass flow at maximum/minimum nominal output
gps
18.0/4.5
17.5/5.6
Flue gas temperature 176/140 °F (80/60 °C) at max./min. nominal output
°F ( °C)
171/135 (77/57)
171/135 (77/57)
Flue gas temperature 104/86 °F (40/30 °C) at max./min. nominal output
°F ( °C)
133/91 (56/33)
133/91 (56/33)
CO
2
at maximum nominal output
%
9.4
11.0
CO
2
at minimum nominal output
%
8.6
10.4
Condensate
Maximum condensate quality (t
R
= 86 °F (30 °C))
gph (l/h)
0.32 (1.2)
0.32 (1.2)
pH level approx.
4.8
4.8
General