Bosch Climate 5000 SCI 18 CAS/ OU- OUE Owner'S Manual Download Page 6

6

 

Climate 5000 SCI – 6720887397 (2018/04)

 Care and Maintenance

Press tabs to 

release grille

Fig. 6. 

3.  Detach the grille from the main unit by holding the grille at a 45° 

angle, lifting it up slightly and then pulling the grille forward.

NOTE:

Some models include an auto-lifting panel function, which allows the 

grille to move vertically and simplifies the filter cleaning process.

Fig. 7. 

4.  Remove the air filter.
5.  Clean the air filter by vacuuming the surface or washing it in warm 

water with mild detergent.

a.  If a vacuum cleaner is used, the inlet side should face the vacuum.

Fig. 8. 

b.  If water is used, the inlet side should face down and away from 

the water stream

Fig. 9. 

6.  Rinse the filter with clean water and allow it to air-dry. 

DO NOT

 let 

the filter dry in direct sunlight.

7.  Reinstall the filter.
8.  Reinstall the front grille and reconnect the display panel cable to the 

control box on the main body.

4.3 

Repairing Refrigerant Leaks

WARNING

 

If the refrigerant leaks, isolate the air conditioner and any combusti-

ble heating devices, ventilate the room and call qualified personnel 

immediately. Refrigerant is both toxic and flammable. 

DO NOT

 use 

the air conditioner until the leak is repaired.

 

When the air conditioner is installed in a small room, measures must 

be taken to prevent the refrigerant concentration from exceeding 

the safety limit in the event of refrigerant leakage.  Concentrated 

refrigerant causes a severe health and safety threat.

Refrigerant Leak Detection System (some models)

 

In the event of a refrigerant leak, the LCD screen will display “EC” 

and the LED indicator light will flash.

4.4 

Preparation For Periods Of Non-Use

Maintenance after Extended Non-Use

1.  Remove any obstacles blocking the vents of both the indoor and 

outdoor units.

2.  Clean the air filter and the front grille of the indoor unit. Reinstall the 

clean, dry air filter in its original position.

3.  Turn on the main power switch at least 12 hours prior to operating 

the unit.

Storing the Unit While Not In Use

1.  Run the appliance on FAN mode for 12 hours in a warm room to dry 

it and prevent mold.

2.  Turn off the appliance and isolate the power.
3.  Clean the air filter according to the instructions in the previous 

section. Reinstall the clean, dry filter before storing.

4.  Remove the batteries from the remote control.

Summary of Contents for Climate 5000 SCI 18 CAS/ OU- OUE

Page 1: ...NDITIONER Climate 5000 SCI CL5000SCI 18 CAS OU OUE 24 CAS OU OUE 36 CAS OU OUE 48 CAS OU OUE Owner s Manual Read this manual carefully before installing or operating your new air conditioning unit Ensure to save this manual for future reference ...

Page 2: ...installation may cause water leakage electric shock or fire The warranty will be void if the unit is not installed by Qualified Personnel If an abnormal situation arises like a burning smell turn off the power supply and call a qualified personel for instructions to avoid electric shock fire or injury DO NOT let the indoor unit or the remote control get wet It may cause electric shock or fire DO N...

Page 3: ... check the indoor unit to see if anything is damaged If the indoor unit is damaged it may fall and cause injury If the air conditioner is used together with other heating devices thoroughly ventilate the room to avoid oxygen deficiency DO NOT climb onto or place objects on top of the outdoor unit DO NOT operate the air conditioner when using fumigant insec ticides The chemicals may become layered ...

Page 4: ...ailure the angle of the horizontal louvers will automatically return to the previous position The angle of the horizontal louver should not be set too small as condensation may form and drip into the machine To reset the louver press the manual button which will reset the horizontal louver settings Refrigerant Leak Detection System Some Models Intheeventofarefrigerantleak theLCDscreenwilldisplay E...

Page 5: ...ll wires are connected correctly Failure to connect wires according to instructions can result in electrical shock or fire 4 1 Unit Maintenance BEFORE CLEANING OR MAINTENANCE Always turn off your air conditioning system and isolate the power supply before cleaning or maintenance DO NOT use chemicals or chemically treated cloths to clean the unit DO NOT use benzene paint thinner polishing powder or...

Page 6: ...d call qualified personnel immediately Refrigerant is both toxic and flammable DO NOT use the air conditioner until the leak is repaired When the air conditioner is installed in a small room measures must be taken to prevent the refrigerant concentration from exceeding the safety limit in the event of refrigerant leakage Concentrated refrigerant causes a severe health and safety threat Refrigerant...

Page 7: ...starts in HEAT mode after defrosting white mist may be emitted due to moisture generated from the defrosting process The indoor unit makes noises A squeaking sound is heard when the system is OFF or in COOL mode The noise is also heard when the drain pump optional is in operation A squeaking sound may occur after the unit is run in HEAT mode due to expansion and contraction of the unit s plastic p...

Page 8: ...ak or long term use Check for leaks re seal if necessary and top off refrigerant The unit starts and stops fre quently There is too much or too little refrigerant in the system Check for leaks and recharge the system with refrigerant There is air incom pressible gas or foreign material in the refriger ation system Evacuate and recharge the system with refrigerant System circuit is blocked Determin...

Page 9: ...model malfunction 10 Off E9 10 Overload protection 1 On F0 11 Outdoor temperature sensor error 2 On F 1 12 Outdoor condenser pipe sensor error 3 On F2 13 Discharge air temperature sensor error 4 On F3 14 Outdoor EEPROM Electrically Erasable Programmable Read Only Memory error 5 On F4 15 Outdoor fan speed DC fan motor only malfunction 6 On F5 16 Auto lifting panel communication error 8 On F7 17 Aut...

Page 10: ...perature sensor E5 Quick flash 6 Outdoor malfunction Quick flash Quick flash E6 Quick flash Quick flash 7 EEPROM malfunction Quick flash Quick flash E7 8 Water level alarm malfunction E8 Quick flash 9 DC motor speed out of control Quick flash Eb Quick flash 10 Outdoor unit low pressure malfunction Quick flash Quick flash Eb Quick flash 11 Auto lifting panel communication error Quick flash F0 Quick...

Page 11: ... and other potentially hazardous materials When this appliance is disposed of the law requires special collection and treatment DO NOT dispose of this product as household waste or unsorted municipal waste NOTE Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment Hazardous substances may leak into the ground water and enter th...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Page 16: ...Bosch Thermotechnology Ltd Cotswold Way Warndon Worcester WR4 9SW mailto Commercial enquiry uk bosch com Contact Number 03301233004 Web address www bosch industrial co uk ...

Reviews: