background image

14

Installation Instructions

The remote controller will indicate  when the neutralizer unit is in need of replacement by displaying an error code.
Therefore, the remote controller should always be installed with this water heater in order to prevent an unexpected
disruption of hot water service.

The bathroom and sub controllers have a maximum temperature setting of 50

°

C for safety. To ensure compliance with

Australian Standard AS/NZS3500.4, for sanitary  areas, which may be achieved by using a Bosch appliance with a
delivery temperature greater than 50

°

C and installed with a tempering valve. In New Zealand, please refer to the New

Zealand Building Code and all other applicable electrical, gas fitting and plumbing codes.

Install the remote controller according to the installation guide.

* The Bosch water heater has been factory set to allow a maximum temperature setting of 55

°

C.

To change the maximum temperature setting, connect the temperature selection wire as shown in the
below diagram. The default temperature is 55

°

C when the temperature selection wire is not connected.

<The changing procedure of the maximum temperature setting.>
1. Turn the water heater off by pressing the ON/OFF button on the remote controller.

2. Disconnect electrical power to the water heater.

3. Remove the front cover of the water heater (4 screws).
4. Connect "WATER TEMPERATURE ADJUSTMENT CONNECTOR" tag

connector to temperature that wants to switch "75

°

C (red wire)" or "60

°

C

(yellow wire)" tag connector as shown on the right.

5. Replace the front cover of the water heater (4 screws).
6. Reconnect electrical power to the water heater.

Main controller

Bathroom  controller

Sub  controller

Bathstop

YPRM67XB

YPRS67XB

YPRP62XB

Max temperature 75

°

C *

Max temperature 50

°

C

Max temperature 50

°

C

Applicable Model

* Maximum temperature is controlled by the maximum default temperature set in the water heater.

Remote controller

YPRM67XB

YPRS67XB

YPRP62XB

* Bath Fill temperature setting is 37 - 48

°

C.

Factory Setting

37 - 55

°

C

37 - 50

°

C

37 - 50

°

C

Connect "75

°

C"

37 - 75

°

C

37 - 50

°

C

37 - 50

°

C

Connect "60

°

C"

37 - 60

°

C

37 - 50

°

C

37 - 50

°

C

• When changing the temperature, make sure to confirm with the customer that the temperature of

the hot water will be very high and that there is a risk of scalding.

WARNING

"60

°

C" tag

"75 

°

C" tag

60

°

C

75 

°

C

W

ATER TEMPERA

TURE

ADJUSTMENT CONNECT

OR

WATER TEMPERATURE
ADJUSTMENT CONNECTOR

It is recommended that for sanitary fixtures use primarily for the purpose of personal hygiene,
that a temperature control device be fitted (such as a tempering valve) as per AS3498.

Remote Controller

The following combination of remote controls will operate the water heater.

Only Main Controller

Works

Only Bathroom Controller

Won't work

Only Sub Controller

Won't work

Main & Bathroom Controller

Works

Main, Bathroom & 1 or 2 Sub Controllers

Works

Main & Sub Controller

Won't work

Bathroom & Sub Controller

Won't work

Summary of Contents for BC2600RA

Page 1: ...tion of unit to customer before leaving 4 customer Failure to install this appliance in accordance with these installation instructions may void warranty In the interest of continued product improvement Bosch reserves the right to alter these specifications without notice 1 Correct commissioning of this rating label Hand these instructions to This appliance must be installed in accordance with the...

Page 2: ...completing installation please either place this Installation Manual in a plastic pouch and attach it to the side of the water heater or hand it to the customer to retain for future reference WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Installation Manual CONDENSING GAS WATER HEATER Bosch Eco26 BC...

Page 3: ...ed with the units but may be necessary for installation Q ty Shape Part Part Shape Q ty 1 Main Controller YPRM67XB 1 Bathroom Controller YPRS67XB Sub Controller YPRP62XB 1 Priority Burneron Temp Bath Fill ON OFF Bath Fill Volume setting Set Time Press 2sec to set time Main Controller YPRM67XB Priority Burneron Temp Bath Fill ON OFF Bath Fill Priority Call Bathroom Controller YPRS67XB Priority Burn...

Page 4: ...line is sized for 178 MJ hr for this unit DO NOT OPERATE WITH ANY OTHER GAS TYPE Check the Power The power supply required is 240 230VAC at 50Hz Using the incorrect voltage may result in fire or electric shock Warning labels Located on the right side of the casing PLEASE READ THESE LABELS CAREFULLY Use Extreme Caution if Using With a Solar Pre Heater A solar transfer valve must be installed with a...

Page 5: ...rials This will cause carbon monoxide poisoning and a potential fire hazard Avoid places where fires are common such as those where petrol benzene and adhesives are handled or places in which corrosive gases ammonia chlorine sulfur ethylene compounds acids are present May result in fire Avoid installation in places where dust or debris will accumulate Dust may block the air supply opening causing ...

Page 6: ...er where the exhaust will blow on outer walls or material not resistant to heat Also consider the surrounding trees and animals The heat and moisture from the water heater may cause discoloration of walls and resinous materials or corrosion of aluminium materials Do not locate the vent termination directed towards a window or any other structure which has glass or wired glass facing the terminatio...

Page 7: ...r externalcorner 500 300 d Froma gasmeter 1000 1000 e From an electricity meter or fusebox P 500 500 f Froma drain pipe or soil pipe 150 75 g Horizontallyfrom any building structure or obstruction facing a flue terminal 500 500 h From any other flue terminal cowl or combustion air intake 500 300 j Horizontallyfrom an opening window door non mechanicalair inlet Or other opening into a building with...

Page 8: ...our screws two for the top bracket and two for the bottom and remove the unit Installation must conform with all local building water or Gas Regulations or AS5601 The weight of the device will be applied to the wall If the strength of the wall is not suffi cient reinforcement must be done to prevent the transfer of vibration Do not drop or apply unnecessary force to the device when installing Inte...

Page 9: ...as Supply Pressure Min 2 75 kPa Max 3 50 kPa 7 Gas Piping The appliance must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 3 5 kPa The appliance and its gas connections must be leak tested before placing the appliance in operation The inlet gas pressure must be within the range specified This is for the purposes of input...

Page 10: ...event the pipe from freezing Make sure that there are no water leaks from the cold and hot water supply pipes then insulate the pipes completely Be sure to also completely insulate the water supply valve and the cold and hot water connections on the water heater refer to the figure on the right Do not cover the water drain plug with insulation so that water in the pipe can be drained Refer to the ...

Page 11: ...ot use lead PVC iron or any piping which has been treated with chromates boiler seal or other chemicals Keep the pipe lengths to a minimum and make sure that the pipework is well insulated as correct performance of the appliance is dependent on properly insulated pipework DO NOT FIT ANY VALVES OR RESTRICTORS TO THE OUTLET OF THE WATER HEATER DO NOT FIT ANY OBSTRUCTION TO THE PRESSURE RELIEF LOCATE...

Page 12: ...ZE OF THIS FITTING OR THE CONDENSATE PIPING TO LESS THAN 15mm 1 2 BSP Use plastic pipe such as PVC for the drain line Do not use steel black iron or any other material which can corrode when placed into contact with water Keep the length of the drain pipe as short as possible Horizontal runs must be sloped 1 50 downwards the drain The end of the drain pipe must not be submerged in water or blocked...

Page 13: ...ppliance If the power cord is damaged and requires replacement use only an original spare part available from the manufacturer Do not disconnect the power supply when not in use When the power is off the freeze prevention in the water heater will not activate resulting in possible freezing damage Do not let the power cord contact the gas piping Tie the redundant power cord outside the water heater...

Page 14: ...ct WATER TEMPERATURE ADJUSTMENT CONNECTOR tag connector to temperature that wants to switch 75 C red wire or 60 C yellow wire tag connector as shown on the right 5 Replace the front cover of the water heater 4 screws 6 Reconnect electrical power to the water heater Main controller Bathroom controller Sub controller Bathstop YPRM67XB YPRS67XB YPRP62XB Max temperature 75 C Max temperature 50 C Max t...

Page 15: ...to the terminal block 1 Check to make sure that the remote controller cord has plenty of slack in order to reach the external connection terminal block 2 Disconnect electrical power to the water heater 3 Remove the single screw securing the terminal block cover and then remove the cover 4 Pass the remote controller cord through the wiring throughway and connect the Y terminals at the end of the re...

Page 16: ...lified service technician Do not obstruct the flow of combustion and ventilation air See Owner s Guide for further maintenance Warning There is a scald potential if the output temperature is set too high Should overheating occur or the gas supply fail to shut off turn off the manual gas control valve to the appliance Do not use this appliance if any part has been under water Immediately call a qua...

Page 17: ...ell of gas remains stop and follow the instructions on page 3 of Owner s Guide 6 Turn the gas control manual valve counterclockwise to the on position 7 Turn on electric power to the unit 8 The unit will now operate whenever hot water is called for If the unit will not operate follow the shutdown instructions and call a service technician Shutdown Instructions 1 Stop any water demand 2 Turn off el...

Page 18: ...5 60 42 42 2 6 5 120 85 50 10 10 622 13 567 600 566 31 10 10 20 28 267 334 350 260 3 6 5 x 16 5 OBLONG HOLE AIR INLET AIR INLET HEIGHT OF EACH FITTING FROM BOTTOM OF CASE HOT WATER OUTLET COLD WATER INLET GAS INLET DRAIN OUTLET 44 57 49 28 DRAIN OUTLET WATER DRAIN VALVE HOT WATER OUTLET PRESSURE RELIEF VALVE WATER DRAIN VALVE GAS INLET WIRING THROUGHWAYS WATER FILTER WATER DRAIN VALVE COLD WATER I...

Reviews: