© 2018 Bosch Security Systems, Inc.
F.01U.297.873 | 08 | 2018.05
8 | Keypad cleaning
Use a soft cloth or a non-abrasive cleaning solution. Spray the cleaner
onto the cloth, not the keypad.
Copyright
This document is the intellectual property of Bosch Security
Systems, Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this
document are likely to be registered trademarks and must be
treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to
the Bosch Security Systems, Inc. website at
http://www.boschsecurity.com/datecodes/.
El-gr: Μεταβείτε στη διεύθυνση https://gr.boschsecurity.com/el/ για την
τεκμηρίωση σε αυτήν τη γλώσσα.
Es-es: Visite https://es.boschsecurity.com/es/ para obtener documentación en
este idioma.
Fr-fr: Accédez à l’adresse https://fr.boschsecurity.com/fr/ pour obtenir la
documentation dans cette langue.
Hu-hu: A honosított dokumentációt lásd a https://hu.boschsecurity.com/hu/
oldalon.
It-it: Andare a https://it.boschsecurity.com/it/ per la documentazione in questa
lingua.
Pl-pl: Dokumentacja w tym języku znajduje się w witrynie https://pl.boschsecurity.
com/pl/
Pt-br: Acesse http://pt.boschsecurity.com/pt/ para obter a documentação neste
idioma.
9 | Specifications
Dimensions
5.5 in x 4.7 in x 1 in (139 mm x
118 mm x 23 mm)
Voltage (input)
12 VDC nominal
Current
35 mA in standby mode
70 mA in alarm mode
Operating temperature
0°C to +50°C (+32°F to +122°F)
Relative humidity
5% to 93% at +32°C (+90°F)
non-condensing
Terminal wire size
18 AWG to 22 AWG
(1.02 mm to 0.65 mm)
SDI2 wiring
Maximum distance - wire size
(unshielded wire only):
984 ft (300 m) - 18 AWG to 22
AWG (1.02mm to 0.65 mm)
Compatibility
B9512G/B9512G-E
B8512G/B8512G-E
B6512
B5512 version 2.03 and higher
B4512 version 2.03 and higher
B3512 version 2.03 and higher
D9412GV4 version 2.03 and
higher
D7412GV4 version 2.03 and
higher
(Refer to the control panel
installation document for the
number of supported devices.)
10 | Certifications
Region
Certification
US
UL 365 - Police Station Connected Burglar Alarm
Units and Systems
UL 609 - Local Burglar Alarm Units and Systems
UL 636 - Holdup Alarm Units and Systems
UL 985 - Household Fire Warning System Units
UL 1023 - Household Burglar-Alarm System Units
UL 1076 - Proprietary Burglar Alarm Units and
Systems
UL 1610 - Central Station Burglar Alarm Units
CSFM - California Office of The State Fire Marshal
FCC Part 15 Class B
CP-01-2010 - Control Panel Standard - Features
for False Alarm Reduction
CA
Canada CAN/ULC S303 - Local Burglar Alarm
Units and Systems
CAN/ULC S304 - Signal Receiving Centre and
Premise Alarm Control Units
CAN/ULC S545 - Residential Fire Warning System
Control Units
CAN/ULC S559 - Fire Signal Receiving Centres
and Systems
ULC-ORD C1023 - Household Burglar Alarm
System Units
ULC-ORD C1076 - Proprietary Burglar Alarm
Units and Systems
ICES-003 - Digital Apparatus
Remove, then add power. The model number, keypad
address, and firmware version show for 10 seconds.
7 | Showing the firmware version
NOTICE!
You can also view a keypad’s firmware version in RPS.
The control panel supervises all SDI2 devices. Any device
that fails to respond will be declared missing.
6 | Supervision
5 | Audible tones
Tone
Description
Fire signal
When an area is in fire alarm, the keypad
emits a pulsed, high-pitched bell tone.
Gas signal
When a gas point activates, the keypad
emits a unique high-pitched tone.
User alarm
When a user alarm (such as panic and
medical alarms) occurs, the tone sounds
for the programmed amount of time.
Burglary signal
When an area is in alarm, the keypad
emits a steady, high-pitched bell tone.
Entrance
warning
During delay periods, the keypad emits an
intermittent beep to remind the user to
disarm the area.
Exit warning
During exit delay, the keypad emits an
intermittent beep.
Invalid button
buzz
When an invalid button, or sequence of
buttons, is pressed, the keypad emits a
flat buzz tone.
Keypad
encoding tone
When the keypad accepts an entry, it
emits a muted beep tone as each button
is pressed.
Trouble buzzer
When a trouble event occurs, such as a
service alert, the keypad emits a two-tone
warble until you enter a programmed
passcode with the appropriate authority.
Watch tone
Anytime a watch point is faulted, a single
clean tweedle tone alerts the user.
Status
indicator
Function
Green - Ready to turn Part On
Red - Part On (part armed)
Green - ready to turn All On
Red - All On (all armed)
Yellow - System trouble
Blue - AC power present
4 | Status indicators
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
en
Installation Guide
Basic Keypad