1 | Overview
3.2 | Attaching the grounding wire
(models B10, D2203, AE1, and AE2)
1. Put the grounding wire lug onto the bolt
2. Attach it with a nut and a washer.
3. Put the other end of the wire onto the door hinge.
2 | SDI2 address settings
3 | Installation
The enclosure holds the module. Wires attach the module to the
control panel, SD12 expansion modules, and any other device.
NOTICE!
Remove all power (AC and battery) before making any
connections. Failure to do so might result in personal
injury and/or equipment damage.
3.1 | Install the module in the enclosure
(models B10, D2203, AE1, and AE2)
Callout ― Description
1 ― Mounting screws
2 ― B10, D2203, AE1, and AE2 enclosures
3 ― Standoff locations
4 ― Plastic mounting clips
5 ― Batteries (up to two 7 Ah or one 18 Ah batteries)
6 ― B520 module
1. Install the mounting clips onto the appropriate standoff
locations inside the enclosure. Callout # 3 in the
following illustration.
2. Put the module onto the mounting clips.
3. Attach the module with mounting screws.
Callout ― Description
1 ― B8103 enclosure (also applicable for BATB-40)
2 ― Support posts
3 ― Mounting plate
4 ― Lock down tab
5 ― Plate mounting hole
6 ― Mounting plate hooks
2.1 | Setting the address settings
NOTICE!
Finland: Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan.
Norway: Apparatet må tilkoples jordet stikkontakt.
Sweden: Apparaten skall anslutas till jordat uttag.
1. Set the switches using a screwdriver.
2. For single-digit address numbers 1 through 9, set the
tens switch to 0 and the ones switch to the appropriate
number.
The following illustration shows an example of address “12.”
NOTICE!
Do not use B10 or D2203 enclosures for Commercial
Fire applications.
3.4 | Mount the B12 mounting plate
in the enclosure (model B8103
)
1. Put the mounting plate in the back of the enclosure.
2. Set the tabs of the enclosure into the two mounting
skirt hooks.
3. Attach the tab to mounting hole with the screw. Refer to
the following illustration.
3.3 | Attach the module in the enclosure
(model B8103)
The enclosure attaches to a B12 mounting plate.
Callout ― Description
1 ― Mounting screws
2 ― B520 module
3 ― B8103 Enclosure (applicable for BATB-40 as well)
4 ― B12 mounting plate
5 ― Plastic mounting clips
6 ― Batteries (holds up to two 7 Ah or two 18 Ah batteries)
3.5 | Attaching the module onto the
mounting plate
Refer to Section 3.1 for installation steps as well as the fol-
lowing illustration.
7
7
NOTICE!
To help prevent damage from electrostatic charges or
other transient electrical surges, connect the system
to earth ground before making other connections.
1. Use 14 AWG (1.6 mm) to 16 AWG (1.3 mm) wire for the
connection. Do not use telephone or electrical ground.
2. Use a grounding rod or a cold water pipe.
3. Install the wire as close as possible to the grounding
device.
NOTICE!
The module reads the address switch setting only
during power up. Cycle the power to the module in
order for the new setting.
The control panel uses the address for communications. Use
the control panel configuration to set the address switches. If
multiple modules are on the same system, each module must
have a unique address.
This module adds a maximum of 2A of 12 VDC power for Fire
and Burglar standby power applications.
Callout ― Description
1 ― Address switches
2 ― EARTH ground connector terminal
3 ― 18 VAC transformer input terminal
4 ― BATT 1 and BATT 2 terminals
5 ― SDI2 IN terminals (from control panel)
6 ― SDI2 OUT terminals and interconnect wiring connector
7 ― Auxiliary power terminals
8 ― Tamper switch connector
9 ― AC LED
10 ― BATT 1 and BATT 2 LEDs
11 ― Heartbeat LED