Dimensions
59.5 mm x 108 mm x 16 mm (2.19 in x 4.25 in x 0.629 in)
Voltage (operating)
12 VDC nominal
Current (maximum)
100 mA max
Connectors
LAN/WAN: RJ-45 modular port (Ethernet)
Ethernet cable
Category 5 or better unshielded twisted pair, 100 m (328 ft) max length
Interface
IEEE 802.3
Data bus wire size
1.02 mm to 0.65 mm (18 AWG to 22 AWG)
Data bus wire length
Maximum distance - Wire size:
150 m (500 ft) - 0.65 mm (22 AWG)
300 m (1000 ft) - 1.02 mm (18 AWG)
Web browser
Microsoft Internet Explorer 6 or higher; Mozilla Firefox 3 or higher
Compatibility
D9412, D7412, D7212, D9112
G Series Version 6.3 or higher
GV2 Series
GV3 Series
GV4 Series
B5512/B4512/B3512
8 | Specifications
5 | LED descriptions
The B426 module includes the following on-board LEDs to assist
with troubleshooting issues (refer to
Figure 1.1
for the location of the
LEDs):
– Heartbeat (system status). Refer to
Table 5.1
.
– Data Bus communication. Refer to
Table 5.2
– Ethernet communication. Refer to
Table 5.3.
Flash pattern
Function
Flashes once
every 1 sec
Normal state: Indicates normal operation state.
3 quick flashes
every 1 sec
Communication error state: Indicates (the
module is in a “no communication state”)
resulting in an SDI2 communication error.
On Steady
LED trouble state: Module is not powered
(for OFF Steady only), or some other
trouble condition prohibits the module from
controlling the heartbeat LED.
Off
Table 4.1: Heartbeat LED descriptions
Flash pattern
Function
RX (Receive)
flashes
Occurs when the control panel bus receives a
message.
TX (Transmit)
flashes
Occurs when the control panel bus sends a
message.
Table 4.1: Data bus LEDs descriptions
LINK (yellow)
flash pattern
100mb (green)
flash pattern
Function
Off
Off
No Ethernet link
On Steady
Off
10 BASE-T link
Flash
Off
10 BASE-T activity
On Steady
On Steady
100 BASE-T link
Flash
On Steady
100 BASE-T activity
Table 4.1: Ethernet LINK and 100mb LEDs descriptions
7 | Certifications
Region
Certification
Applicable control panels
US
UL 365 – Police Station Connected Burglar Alarm Units and Systems
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 609 – Local Burglar Alarm Units and Systems
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 864 – Control Units and Accessories for Fire Alarm Systems
(Including NFPA 72)
GV4 Series, GV3 Series, GV2 Series, FPD-7024
UL 985 – Household Fire Warning System Units
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 1023 – Household Burglar Alarm System Units
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 1076 – Proprietary Burglar Alarm Units and Systems
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
UL 1610 – Central Station Burglar Alarm Units
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
FCC Part 15 Class B, NIST FIPS-197 AES Certification
(IP Communications)
B5512/B4512, GV4 Series, GV3 Series, GV2 Series, G Series,
DS7200, DS7400, Easy Series V3+, AMAX 2000
Canada
CAN/ULC S303 - Local Burglar Alarm Units and Systems
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
CAN/ULC S304 - Signal Receiving Centre and Premise Alarm Control
Units
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
ULC-ORD C1023 - Household Burglar Alarm System Units
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
ULC-ORD C1076 - Proprietary Burglar Alarm Units and
Systems
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
ICES-003 - Digital Apparatus
B5512/B4512, GV4 Series, GV3 Series, GV2 Series
When the tamper switch is activated (closed to open), the heartbeat
LED stays OFF for 3 sec before indicating the firmware version.
The LED pulses the major, minor, and micro digits of the firmware
version, with a 1 sec pause after each digit.
Flashing patterns do not start until the tamper is open (short is
removed). In the following is an example, the version 1.4.3 shows as
LED flashes:
[3 sec pause]
*___****___***
[3 sec pause, then normal operation].
To show the firmware version using an LED flash pattern:
– If the optional tamper switch is installed:
With the enclosure door open, activate the tamper switch (push and
release the switch).
– If the optional tamper switch is NOT installed: Momentarily short
the tamper pins.
Refer to
Figure 6.1
for an example of flash patterns.
6 | Show the firmware version
Figure 6.1: Firmware LED flash patterns
For complete installation, confi guration, and testing instructions,
refer to the
Conettix Ethernet Communication Module (B426)
Installation and Operation Guide
provided on the supplied
CD-ROM.
en
Installation Guide (UL)
Conettix Ethernet Communication
Module
B426