Bosch B426 Installation Manual Download Page 2

Bosch Security Systems, Inc.

130 Perinton Parkway

Fairport, NY 14450

USA

www.boschsecurity.com

© 2013 Bosch Security Systems, Inc.   

F.01U.281.209 | 02 | 2013.08

Copyright

This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.

Trademarks

All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.

Bosch Security Systems, Inc. product manufacturing dates

Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at 

http://www.boschsecurity.com/datecodes/.

Dimensions

59.5 mm x 108 mm x 16 mm (2.19 in x 4.25 in x 0.629 in)

Voltage (operating)

12 VDC nominal

Current (maximum)

100 mA max

Connectors

LAN/WAN: RJ-45 modular port (Ethernet)

Ethernet cable

Category 5 or better unshielded twisted pair, 100 m (328 ft) max length

Interface

IEEE 802.3 

Data bus wire size

1.02 mm to 0.65 mm (18 AWG to 22 AWG)

Data bus wire length

Maximum distance - Wire size: 

150 m (500 ft) - 0.65 mm (22 AWG)

300 m (1000 ft) - 1.02 mm (18 AWG)

Web browser

Microsoft Internet Explorer 6 or higher; Mozilla Firefox 3 or higher

Compatibility

D9412, D7412, D7212, D9112

G Series Version 6.3 or higher

GV2 Series

GV3 Series

GV4 Series

B5512/B4512/B3512

8 | Specifications

5 | LED descriptions

The B426 module includes the following on-board LEDs to assist 

with troubleshooting issues (refer to 

Figure 1.1 

for the location of the 

LEDs): 

– Heartbeat (system status). Refer to 

Table 5.1

.

– Data Bus communication. Refer to 

Table 5.2

– Ethernet communication. Refer to 

Table 5.3.

Flash pattern

Function

Flashes once 

every 1 sec

Normal state: Indicates normal operation state.

3 quick flashes 

every 1 sec

Communication error state: Indicates (the 

module is in a “no communication state”) 

resulting in an SDI2 communication error.

On Steady

LED trouble state: Module is not powered 

(for OFF Steady only), or some other 

trouble condition prohibits the module from 

controlling the heartbeat LED.

Off

Table 4.1: Heartbeat LED descriptions

Flash pattern

Function

RX (Receive) 

flashes

Occurs when the control panel bus receives a 

message.

TX (Transmit) 

flashes

Occurs when the control panel bus sends a 

message.

Table 4.1: Data bus LEDs descriptions

LINK (yellow)

flash pattern

100mb (green)

flash pattern

Function

Off

Off

No Ethernet link

On Steady

Off

10 BASE-T link

Flash

Off

10 BASE-T activity

On Steady

On Steady

100 BASE-T link

Flash

On Steady

100 BASE-T activity

Table 4.1: Ethernet LINK and 100mb LEDs descriptions

7 | Certifications

Region

Certification

Applicable control panels

US

UL 365 – Police Station Connected Burglar Alarm Units and Systems

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

UL 609 – Local Burglar Alarm Units and Systems

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

UL 864 – Control Units and Accessories for Fire Alarm Systems 

(Including NFPA 72)

GV4 Series, GV3 Series, GV2 Series, FPD-7024

UL 985 – Household Fire Warning System Units

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

UL 1023 – Household Burglar Alarm System Units

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

UL 1076 – Proprietary Burglar Alarm  Units and Systems

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

UL 1610 – Central Station Burglar Alarm Units

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

FCC Part 15 Class B, NIST FIPS-197 AES Certification 

(IP Communications)

B5512/B4512, GV4 Series, GV3 Series, GV2 Series, G Series, 

DS7200, DS7400, Easy Series V3+, AMAX 2000

Canada

CAN/ULC S303 - Local Burglar Alarm Units and Systems

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

CAN/ULC S304 - Signal Receiving Centre and Premise Alarm Control 

Units

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

ULC-ORD C1023 - Household Burglar Alarm System Units

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

ULC-ORD C1076 - Proprietary Burglar Alarm Units and

Systems

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

ICES-003 - Digital Apparatus

B5512/B4512, GV4 Series, GV3 Series, GV2 Series

When the tamper switch is activated (closed to open), the heartbeat 

LED stays OFF for 3 sec before indicating the firmware version. 

The LED pulses the major, minor, and micro digits of the firmware 

version, with a 1 sec pause after each digit.
Flashing patterns do not start until the tamper is open (short is 

removed). In the following is an example, the version 1.4.3 shows as 

LED flashes:

[3 sec pause] 

*___****___***

 [3 sec pause, then normal operation].

To show the firmware version using an LED flash pattern: 

– If the optional tamper switch is installed: 

With the enclosure door open, activate the tamper switch (push and 

release the switch).

– If the optional tamper switch is NOT installed: Momentarily short 

the tamper pins.

Refer to 

Figure 6.1 

for an example of flash patterns. 

6 | Show the firmware version

Figure 6.1: Firmware LED flash patterns

For complete installation, confi guration, and testing instructions,

refer to the 

Conettix Ethernet Communication Module (B426)

Installation and Operation Guide

 provided on the supplied

CD-ROM.  

en

   Installation Guide (UL)

Conettix Ethernet Communication 

Module

B426