The air inside a room is circulated through a set of
purifying filters when the appliance is set to this
function.

The appliance comes with a main filter with a
double active purifying filter. This special filter is
for:

- Smells and smoke.
- Pollen, bacteria and dust.

Put the air expulsion duct in the same position as
for dehumidification.

Set purification speed setting:     maximum
or silent     .

When the appliance or the model is fitted with
optional filters, we recommend you leave the
optional filters in position regardless of the
desired function setting (cooling,
dehumidification, air purification). The appliance
purifies the air more efficiently in this way.

When set to     , the appliance removes humidity
from the atmosphere. It does not, however, control
the temperature.

Turn drainage stopcock 90° in an anti-clockwise
direction.

Remove stopcock plug and insert drainage pipe.
stored in the main filter compartment.

Place a bowl at the drainage pipe outlet to collect
the condensed water in.

Put the air extraction duct in storage position.

Set control knob to dehumidification position     .

The amount of water removed from the air can
reach as much as 30 liters/24 hours, depending
on atmospheric conditions.

Warning!

• Do not forget to put the plug back in place on

the drainage stopcock and to turn the
stopcock 90° in a clockwise direction before
setting the appliance to the temperature
control setting. The appliance will shed water
should you fail to do so. 

• Always remember that in order for the

dehumidification function to work properly,

ambient temperature must be at least 18°C.

Air purification

Dehumidification

Summary of Contents for B1 RKM 09004

Page 1: ...GB Instructions for Use B1 RKM 09004 Internet http www bosch hausgeraete de Bosch Info Team DE Tel 01 80 5 30 40 50 0 13 DEM 0 24 Min DTAG ...

Page 2: ...Robert Bosch Hausgeräte GmbH Carl Wery Str 34 D 81739 München Germany ...

Page 3: ...anel 6 Requirements for Use Requirements for use 7 Transportation requirements 7 Instructions for Use Temperature control 8 Ways of releasing air outdoors 9 Dehumidification 10 Air purification 10 Cleaning and Maintenance Cleaning 11 Prior to use at change of season 11 Technical Service Warranty 12 Things that can save you from making unnecessary phone calls 13 Technical Information 14 ...

Page 4: ...ts which need to be disposed of in accordance with current regulations Do not dispose of your old appliance yourself Get in touch with your local council or other competent body for information about how best to dispose of it Before connecting your new appliance Read the instructions book before using your appliance for the first time It contains important information not only concerning use but m...

Page 5: ...liance Purifying filters Diffusion duct Suction pad Hot air expulsion duct Air intake grille Drainage pipe Wire cavity Nozzle to connect drainage pipe to internal tank Nozzle and stopcock for dehumidification drainage pipe Rear hook for hot air expulsion duct Characteristics plate 5 ...

Page 6: ...ol panel Air direction fixture Thermostat Control knob Appliance off Maximum temperature control Silent temperature control Dehumidification Safety pilot light Silent air purification Maximum air purification ...

Page 7: ... be replaced with a wire of similar characteristics Get in touch with the manufacturer after sales service or similarly qualified person Warning If the appliance is turned off and then turned back on again there is a 3 minute interval before the compressor starts up again This interval is necessary in order for the appliance to work properly Transportation requirements There are castors fitted on ...

Page 8: ...t In conditions of extreme humidity the appliance accumulates water in an internal tank When the water in this tank reaches a certain level safety pilot light comes on indicating that the tank needs to be emptied Turn the appliance off and wait 10 minutes for the safety systems to reset Turn drainage stopcock 90 in an anti clockwise direction Remove the plug from stopcock 10 and insert drainage pi...

Page 9: ...in the wall and the wall accessory fitted in order to expel hot air Store the diffusion duct away and connect the air expulsion duct to the accessory Only the transparent end section of the accessory is used when air is to be expelled through a window on a permanent basis A 10 5 cm diameter hole must be made in the glass in order to fit the accessory N B Do not extend the hot air expulsion duct mo...

Page 10: ...rom the atmosphere It does not however control the temperature Turn drainage stopcock 90 in an anti clockwise direction Remove stopcock plug and insert drainage pipe stored in the main filter compartment Place a bowl at the drainage pipe outlet to collect the condensed water in Put the air extraction duct in storage position Set control knob to dehumidification position The amount of water removed...

Page 11: ...year in order to work efficiently Contact your supplier The filters must be fitted as shown in figures Place only one set of filters onto fixture to avoid affecting cooling efficiency The appliance can be cleaned with a cloth or sponge warm water and mild detergent Never use hot water more than 40 C bleach petrol based products acids or brushes when cleaning your appliance Prevent water entering t...

Page 12: ...plate Technical Service Warranty Warranty The conditions of warranty depend on the relevant Supplier in a particular country Contact the establishment where you purchased your appliance for more information and quote the appliance model and factory number The receipt of purchase for the appliance must be produced prior to any work carried out under warranty The following procedures can help you so...

Page 13: ... appliance on a flat surface If the pilot light still doesn t go out then empty the appliance s internal water tank See instructions for Temperature Control Make sure that the drainage stopcock is set to the right position Make sure that the connections on hot air expulsion duct are in working order Make sure that the expulsion duct is not excessively bent or longer than 140 cm Make sure that drai...

Page 14: ...s properly fitted onto the appliance Make sure that the appliance s air inlets and outlets are free from obstruction If the noise sounds like water flowing then this is due to the pump which circulates water around the system so as to enhance the efficiency of the appliance Any other kind of fault or repair work must be dealt with by a specialised technician Contact your authorised supplier the af...

Page 15: ...5401 000 440 Rev a ...

Reviews: