WATER IS TOO HOT

1Gas flow is higher than necessary.
Move gas control slide to the left.

2. Temperature (aquastat) control is set too high
If unit is plumbed in a recirculating loop system the aquastat
temperature relay for the primary circulator pump is possibly
set too high.

WATER IS NOT HOT ENOUGH

1. Water flow rate is too high.
Decrease the flow rate.

2. Gas flow is not optimal
Move gas control slide to the right.

3. Temperature (aquastat) control is set too low
If unit is plumbed in a recirculating loop system the aquastat
temperature relay for the primary circulator pump is possibly
set too low.

4. Btu input is too low due to insufficient gas pressure

It is extremely important for a tankless instantaneous
water heater to have the right size gas line to obtain
the correct gas pressure

See specifications on page 2. Unlike storage tank water
heaters, the burners of a tankless water heater must be
very powerful to heat water instantaneously since they do
this only at the time hot water is actually being used. It is
therefore imperative that the gas pressure requirement be
met exactly.  Insufficient gas pressure will directly affect
the water temperature at the time of usage. See pages 2
for correct gas pressure settings.

5. Btu input is too low due to insufficient gas supply
Make sure your main gas line is fully opened. If using LP
gas, be sure that the size of the propane tank is adequate
to supply the required gas pressure.

6. Cold water is mixing with the hot water between

the AquaStar and the outlet

Compare water temperature at outlet of the AquaStar (hold
the AquaStar’s outlet pipe with your hand) and at the tap.  If
these two are very different, check for mixing valve or
plumbing crossover (see “MAIN BURNERS WILL NOT
IGNITE...” paragraph #5).

7. Parts in water flow valve are corroded so that the

gas passage is not fully opening

Contact your service person or Controlled Energy.

6. Crossover in household plumbing
The AquaStar burner activates when there is sufficient water
pressure drop in the AquaStar water valve assembly — ie.
when a hot water faucet is opened. If there is a crossover in
the plumbing, the necessary pressure drop in the AquaStar
will be insufficient, or totally eliminated.  A plumbing
crossover can be caused by a bad washer at a single lever
faucet or incorrect plumbing or a mixing valve in the line,
etc. which permits hot and cold water to mix in the
plumbing. The crossover will create a back pressure in the
system preventing the pressure drop in the Aquastar (i.e.
cold water is entering the water heater from both sides and
the burners will not come on).
To confirm there is no crossover in the plumbing, shut off
the cold water supply to the AquaStar. Open your hot water
taps.
There should not be any water flowing. If there is water
flowing, there is a crossover in the plumbing. This is a
plumbing problem, not an Aquastar problem. Please contact
your plumber.
7. Water valve parts may be dirty or components

damaged.

First check that the venturi is free from dirt particles.
Water valve and component parts must be totally free of
dirt. In hard water areas, mineral deposits can eventually
(3 to 5 years in hard water areas) corrode the water valve
parts to a point where they will need replacing. Any sign of
moisture or corrosion at the joint of the water valve and the
gas valve is a sign that the water valve assembly
components need to be replaced immediately
.
Note: Water valve for model 125BL is part # 8707002478
for both LP and NG models. (Contact service person to
clean water valve or replace if corrosion is present).

PILOT LIGHT GOES OUT DURING OR AFTER USE

1. Gas pressure too low
Very low gas pressure may be caused by low delivered
gas pressure, a jammed gas regulator or undersized gas
lines. If the gas lines are undersized, there may still be the
specified static gas line pressure. However when the water
valve opens,and gas enters the burners, the pressure could
drop sharply, causing the pilot flame to go out. Have a gas
technician confirm the gas pressure both static and at
maximum Btu output. Specifications for your heater are on
page 2.
2. Pilot may be dirty or weak
See Page 9 for instructions on pilot maintenance.

3. Burners are not shutting down immediately when

hot water is turned off or when a circulator pump
has stopped operating

Note: If burners don’t shut down immediately when the hot
water is turned off, the heater will overheat and the ECO
will shut-off the gas. Rebuild the water valve assembly using
the repair kit from CEC (part#8 703 406 214).

4. Temperature controls are set too high
If unit is plumbed in a recirculating loop system insure that
the aquastat or relay for the primary circulator pump is set
for no hotter than 140°F. This is necessary to prevent pilot
outage due to overheating. The temperature slide control
on the 125BL may also need to be lowered to prevent
overheating.

Summary of Contents for AQUASTAR 125B LPL operati

Page 1: ...the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified in...

Page 2: ...GPM Max Water Pressure 150 Psi Shipping Weight 46 LB Net Weight 44 LB 1 8 GPM at 90 rise 3 7 GPM at 45 rise Min Water Flow 1 8 gal min LP GAS Supply Pressure beforeAquastar regulator min 11 W C max 14 W C Required LP GAS Pressure at inlet tap whileAquastar is operating 10 5 W C LP GAS Burner Manifold pressure whileAquastar is operating at maximum input 9 0 W C Natural Gas Supply Pressure beforeAqu...

Page 3: ...ROM COMBUSTIBLEAND NON COMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONS FRONT VIEW SIDE VIEW AQUASTAR MODEL 125BL Some local codes require 18 in garage installations MODEL 125BL TOP A 12 FRONT B 4 BACK 0 SIDES 4 FLOOR C 12 VENT DIAMETER 5 ...

Page 4: ...de poisoning or fire 3 The place where you install the heater must have enough ventilation The National Fire Codes do not allow gas fired water heater installation in bathrooms bedrooms or any occupied rooms normally kept closed See the section below on locating the heater 4 You must vent your heater See section on VENTING Page 6 5 The appliance must be disconnected from the gas supply piping syst...

Page 5: ...hicles RV or boats Reference ANSI Z21 10 3 This product is neither designed or approved for outside installations WARNING The water in this water heater is cold and always remains cold except for the times that hot water is being used DO NOT INSTALL IN AN AREA WHERE IT COULD FREEZE This heater is neither designed for nor approved for outside installation Drain the heater entirely if freezing tempe...

Page 6: ...arpeted wall or over floor covering which is combustible such as carpet The heater must be mounted on a wall using appropriate anchoring materials If wall is a stud wall sheathed with plasterboard it is recommended that support board s either 1x4 s or 1 2 minimum plywood first be attached across a pair of studs and then the heater should be attached to the support boards See Fig 1 Expansion and co...

Page 7: ...dewall vent Contact your local dealer To check the draft Close all doors and windows to the outside Turn on all appliances that force air out of the building These include all exhaust ventilation fans furnaces clothes dryers wood burning stoves etc Open all doors between the AquaStar and these other ap pliances Run the unit for at least 10 minutes Then hold an ordinary mirror at the side above the...

Page 8: ... 19 _ _ _ _ _ _ 1 2 92 62 50 41 37 35 31 29 27 26 5 8 199 131 107 90 79 72 67 62 59 55 3 4 329 216 181 145 131 121 112 104 95 90 7 8 501 346 277 233 198 187 164 155 146 138 Nominal Iron Length of Black Iron Pipe Feet Pipe Internal Size Diameter inches inches 10 20 30 40 50 60 70 80 90 100 125 150 175 200 1 4 0 364 32 22 18 15 14 12 11 11 10 9 8 8 7 6 3 8 0 493 72 49 40 34 30 27 25 23 22 21 18 17 1...

Page 9: ...ust above the regulator See Fig 4 These readings should be taken while the heater is operating at full input i e with the gas control positioned all the way to the right MAXIMUM INLET GAS FLOW PRESSURE SETTING GAS LINE SIZING It is strongly recommended that the Natural Gas pipe be Black Iron pipe the entire distance from the outside meter to the inlet of the Aquastar regulator 1 2 Black Iron pipe ...

Page 10: ...or gas supplier 7 When lit depress the ON button The heater will now fire when water is drawn at a rate greater than the threshold flow rate NOTE If main burner should fail to ignite make sure pilot is burning If not repeat lighting steps 1 through 6 TO TURN OFF GAS TO APPLIANCE Depress the OFF button and close the gas supply to the heater INFORMATION ABOUT WATER TEMPERATURE The AquaStar 125B LPL ...

Page 11: ...se the heater to deliver less than its full output or to fail to ignite or to shut down completely Problems are stated in upper case bold face Most common causes for the problems follow in order of likelihood The suggested solutions require that the cover be taken off To do this remove incandescent particle tray and unscrew the central screw located at the bottom of the front cover Pull main cover...

Page 12: ... Check the tightness of the thermocouple connection nut at the electromagnet The Electro magnet connection is a large aluminum 17mm hex head nut The thermocouple end is a 5 mm brass nut which screws into the 17 mm nut Tighten the thermocouple nut snugly but not too tight 4 Poor circuit connections at the ECO Energy Cut Off overheat protection Oxidation or looseness of the ECO terminal connections ...

Page 13: ...n the line etc which permits hot and cold water to mix in the plumbing The crossover will create a back pressure in the system preventing the pressure drop in the Aquastar i e cold water is entering the water heater from both sides and the burners will not come on To confirm there is no crossover in the plumbing shut off the cold water supply to theAquaStar Open your hot water taps There should no...

Page 14: ...rnersdoNotIgniteWhenHotWaterTurned On 2 Storage in tank recirculating system has not fully recovered Storage capacity in tank is inadequate Increasing tank size setting slide control higher for a fast recovery or adding a second 125BL for even a faster recovery is suggested 3 Insufficient gas pressure Note required gas pressures page 2 and consult gas ser vice person ...

Page 15: ...1 Heat exchanger 2 Pilot assembly 3 Burner manifold gas pressure test nipple 4 Pilot gas tubing 5 Main gas burner 6 Gas valve 7 Gas control slide 8 Piezo igniter 9 Location of pressure tap nipple 10 Water valve 11 Gas inlet gas pressure test nipple 3 11 9 ...

Page 16: ...16 Fig 11 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST ...

Page 17: ...00 005 LPG 8 748 200 173 14 Pilot Tube 8 710 707 166 15 Thermocouple 8 747 202 083 16 Burner assembly washer 8 710 103 060 17 Throttle disc LPG 8 700 100 174 18 Gas valve NG 8 707 011 460 Gas valve LPG 8 707 011 464 19 Gas supply pipe 8 700 705 464 20 Electromagnet 8 747 201 094 21 Electromagnet washer 8 700 103 144 22 Gas filter 8 700 507 051 23 Thermocable 8 747 202 078 24 Water valve assembly 8...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...ny applicable local codes Water Pressure For installation on well systems insure that your water pressure is between 30 50 psi NOTE Minimum vent height must be 6 feet provided there are no elbows Termination of the vent must be 2 feet above any obstruction within a 10 foot radius of vent pipe Consult your gas utility or National Fuel Gas Code if vent will have elbows or share venting with another ...

Reviews: