background image

 

Engineered Solutions | AMC2 - Input/Output Extension Boards

AMC2 - Input/Output Extension Boards

 

www.boschsecurity.com

 

 

 

 

 

 

 

 

u

RS485 connection to the AMC2 controller

u

Three models available one with 8 inputs & 8
outputs, one with 16 inputs & 16 outputs, and one
with 16 inputs

u

Status of inputs and outputs shows on AMC2 LCD
display

u

Transfer rate to EXT interface (RS485): 9,6 kBit/sec

u

The AMC2 Extensionboards can be supplied with
the PBC-60 power supply unit with integrated UPS.

The AMC2 16I-16O-EXT, the AMC2 16I-EXT and/or the
AMC2 8I‑8O-EXT extension boards can only be used
with the AMC2 access controller and provides
additional input and output contacts.
The AMC2 controller has eight input and eight output
signals. The AMC2 determines the door status (open
or closed) via the analog input signals. The relay
outputs can be used to activate locking mechanisms,
for example.
If there are not enough contacts available on the AMC2
to transfer the necessary signals, up to three AMC2 xI-
xO-EXT units can be connected to provide additional
inputs and outputs.

Notice
Systems with Access Personal Edition Software
can only connect one I/O-Extension to an AMC2
Controller.

The electronics are located in a plastic housing, similar
to the one on the AMC2 controller.
The AMC2 16I-16O-EXT has 16 analog inputs and 16
relay outputs. It receives door status signals via the
inputs and can authorize door releases or send
messages to external surveillance systems via the
outputs.

Reduced versions of the extension board are also
obtainable to make full use of the available signals.
The AMC2 8I-8O-EXT module has eight input and eight
output signals. The AMC2 16I-EXT has 16 analog
inputs.

System overview

The AMC2 xxx-EXT is integrated into the system via the
AMC2 controller.

1 = Host computer
2 = AMC2

Summary of Contents for AMC2 Series

Page 1: ...gnals The relay outputs can be used to activate locking mechanisms for example If there are not enough contacts available on the AMC2 to transfer the necessary signals up to three AMC2 xI xO EXT units can be connected to provide additional inputs and outputs Notice Systems with Access Personal Edition Software can only connect one I O Extension to an AMC2 Controller The electronics are located in ...

Page 2: ...nsmit to another AMC2 Configuration examples Solid lines Power supply Dotted lines Data lines 1 AMC2 with power supply 2 Power and data are supplied to the AMC2 xxx EXT via the AMC2 3 The AMC2 xxx EXT with its own power supply receives data from the AMC2 4 The first AMC2 xxx EXT is supplied by the AMC2 the second has its own power supply and a connection to the third All AMC2 xxx EXTs receive thei...

Page 3: ...Hardware 16 or 8 or null relay outputs with ohm load max switching voltage 30 V DC max switching current 1 25 A 16 or 8 analog inputs Tamper switch Temperature 0 C to 45 C 32 F to 113 F Power supply 10 or 30 V DC max 60 VA Available for external devices 55 VA or via the AMC2 Protection class IP 30 Housing Base PPO UL 94 V 0 Upper Polycarbonate UL 94 V 0 Color White Dimensions WxHxD 232 x 90 x 46 m...

Page 4: ... com Robert Bosch SEA Pte Ltd Security Systems 11 Bishan Street 21 Singapore 573943 Phone 65 6571 2808 Fax 65 6571 2699 apr securitysystems bosch com www boschsecurity asia Bosch Shanghai Security Systems Ltd 201 Building No 333 Fuquan Road North IBP Changning District Shanghai 200335 China Phone 86 21 22181111 Fax 86 21 22182398 www boschsecurity com cn Robert Bosch Ltda Security Systems Division...

Reviews: