Quick Start Guide

Quick Start Guide

WIRING DIAGRAM

Typical FHP560 Wiring Diagram

Wiring Diagram

Summary of Contents for 560 DDC

Page 1: ...tart Guide 560 583 DDC Please refer to the included Hardware User s Guide and BACview Installation and Operation Manual for more detailed information on setting up and using the controllers 8733914716 2014 02 ...

Page 2: ...2 8733914716 DDC 2014 02 Subject to change without prior notice Quick Start Guide Quick Start Guide ...

Page 3: ...rt Guide Software Setup 8 Software Configuration Tools 8 Handheld BACview Module Features 8 Virtual BACview Module Features 9 Getting Connected 10 Configuring Application Parameters using BACview 11 Modifying Parameter Values Using BACview 11 Customizing Program Features Using BACview 12 Useful Shortcuts for Tweaking Program Features Using BACview 12 Configurable I O Port Assignments SW 7 03 06 13...

Page 4: ...sch Inc All rights reserved Quick Start Guide Hardware Setup Controller Features Battery Network LON Connector Rotary Switch Jumper Bank RNET Connector Universal Inputs IN 1 to IN 6 Local Access Port see page 10 24VAC DIP Switch Bank Analog Outputs 583 only Digital Outputs Part Number Hardware Setup FHP 560 Controller ...

Page 5: ...tch corresponding Heat Pump system application If the controller is networked ensure communications jumper is set to EIA 485 unless the network protocol is BACnet over ARC156 Getting Started Input Selection Jumpers for IN 1 IN 2 e g for a 0 5V CO2 Sensor connected to IN 1 the jumper should be set in bottom position IN 1 IN 2 Jumper Settings Label Communications Selection Jumper i e jumper in botto...

Page 6: ...r DIP switches match corresponding network application per the BAS Port Settings BAUD RATES SW1 SW2 9600 Off Off 19 2K Off On 38 4K On Off 76 8K On On PROTOCOLS SW3 SW4 BACnet MS TP Off Off N2 On Off Modbus Off On LON Option On On Sample DIP switch settings for a LON Talk Application Caution The LonTalk card must be installed DIP Switch Settings DIP Switch ...

Page 7: ...ation The rotary dials provide the controller address for identification over a network The top dial represents the tens digit of the address and the bottom dial represents the ones digit for the address See example below In the example to the left the rotary dial is set to 69 Rotary Dial Settings POWER UP Apply power to the unit and verify via the power LED that the controller is receiving 24VAC ...

Page 8: ...values Arrow keys used for navigating the various BACview screens Soft keys four 4 buttons used to access corresponding Soft key Labels directly above them Software Setup Link an arrow next to a menu item implies additional screen s can be accessed through that menu To access a screen navigate to the menu item and hit the ENTER button Note selected fields have a bracket around them Contrast screw ...

Page 9: ...and take note of COM port Download and install Virtual BACview from FHP website http fhp mfg com p controls_support Interface Use mouse to select keypad buttons for shortcut key combinations FN Ctrl on keyboard e g FN 9 is Ctrl 9 Screen size number of rows can be adjusted in Virtual BACview at startup Caution All screen shots of BACview used in this manual are from Virtual BACview and may not repr...

Page 10: ... to change without prior notice Quick Start Guide Quick Start Guide Getting connected Getting Connected Connect the BACview module or laptop if using Virtual BACview to the FHP controller or to an RS Sensor connected to the controller ...

Page 11: ...required to modify the Unit Operation Set point parameters The default administrative password for all FHP controllers is 1111 Sample screen shot from Virtual BACview Actual screen may vary 4 Maneuver through the different sub menus and change parameters to match your application using the Arrow Keys and the Soft Keys Sample screen shot from Virtual BACview Actual screen may vary MODIFYING PARAMET...

Page 12: ...the various features of the controller program match the application of the Heat Pump system Useful Shortcuts for Tweaking Program Features Using BACview Change the User Password Set the Time Access Alarms Change BACnet ID Change Inactivity Timeout Modify Tuning Parameters Change Temperature Offsets Access I O Status Overrides Customizing Program Features ...

Page 13: ...lve End Switch Smoke Detector Switch Fan Status Switch Valve End Switch Dirty Filter Switch Fan Status Switch Differential Pressure Switch Smoke Detector Switch Fan Status Switch Dirty Filter Switch Dirty Filter Switch Fan Status Switch Damper End Switch Smoke Detector Switch Fan Status Switch Secondary Drain Pan IN 6 Discharge Air Temperature DIGITAL OUTPUTS DO 1 Fan DO 2 Reversing Valve DO 3 Com...

Page 14: ...14 8733914716 DDC 2014 02 Subject to change without prior notice Quick Start Guide Quick Start Guide WIRING DIAGRAM Typical FHP560 Wiring Diagram Wiring Diagram ...

Page 15: ... 15 Quick Start Guide Subject to change without prior notice 8733914716 DDC 2014 02 Quick Start Guide Notes ...

Page 16: ...601 N W 65th Court Ft Lauderdale FL 33309 Phone 866 642 3198 Fax 954 776 5529 www fhp mfg com 8733914716 Revised 2014 02 ...