background image

en

    Installation

14

Installation

1.

Attaching and aligning the appliance. 

¨

2.

Mark the hole for the safety screw.

 ©

3.

Remove the appliance once more.

 ª

[

 

!

!

$

%

&

[

 

!

!

$

%

&

[

 

!

!

$

%

&

&

%

$

Installation    

en

15

Finishing installation of the appliance

1.

Drill an 8mm Øhole to a depth of 80mm for the 

safety screw and press the wall plug flush into the 

wall.

 ¨

2.

First remove the protective foil from the back of the 

appliance and, following installation, remove the foil 

completely.

3.

Connect the appliance. 

©

4.

Screw in the safety screw - and washer - and tighten 

all the screws. 

ª

Exhaust duct

Note: 

The device manufacturer does not assume any 

warranty for complaints attributable to the pipe section.

The device achieves its optimum performance by 

means of a short, straight exhaust air pipe and as 

large a pipe diameter as possible.

As a result of long rough exhaust air pipes, many 

pipe bends or pipe diameters that are smaller than 

150 mm, the optimum extraction performance is not 

achieved and fan noise is increased.

The pipes or hoses for laying the exhaust air line 

must consist of non-combustible material.

Round pipes

 

An inner diameter of 150 mm, but at least 120 mm, is 

recommended.

Flat ducts

 

The inner cross-section must correspond to the 

diameter of the round pipes.

dia. 150 mm ca. 177 cm

2

dia. 120 mm ca. 113 cm

2

Flat ducts should not have any sharp deflections.

Use sealing strips for deviating pipe diameters.

Connecting the appliance to the power 

supply

Connecting the air extractor

Note: 

If using an aluminium pipe, smooth the 

connection area beforehand.

1.

Attach the air extractor pipe directly to the air-pipe 

connector.

2.

Connect to air extractor opening.

3.

Seal the joints appropriately.

Connect the power supply

1.

Plug the mains plug into the earthed socket.

2.

If a fixed connection is required, please follow the 

instructions in the 

Electrical Connection

 section.

Attaching the flue duct

:

Warning – Risk of injury! 

Components inside the appliance may have sharp 

edges. Wear protective gloves.

1.

Separate the flue duct sections. 

To do this, remove the adhesive tape.

2.

Remove the pieces of protective film from both flue 

duct sections.

3.

Push one flue duct section into the other.

Notes

– To prevent scratches, lay paper over the edges of 

the outer flue duct section to protect the surface.

– The slots of the inner flue duct section should 

point downwards.

4.

Place the flue ducts sections on the appliance.

5.

Slide the inner flue duct section upwards, and attach 

it to the left and right sides of the retaining bracket. 

¨

6.

Slide the flue duct section down to engage it. 

©

7.

Screw the flue duct section to the sides of the 

retaining bracket using two screws. 

ª

8.

Use two screws to fasten the outer flue duct section 

to the appliance from below. 

«

%

&

$

Summary of Contents for 4242005051236

Page 1: ... en Instructions for installation and use Extractor hood ...

Page 2: ...n This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by ch...

Page 3: ...In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the grease filter may catch fire Regularly clean the grease filter Neve...

Page 4: ...ny high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on the appliance while cooking to avoid condensation Condensate can produce corrosion damage Always replace faulty bulbs to prevent the remaining bulbs from overloading Risk of damage due to ingress of humidity into the electronic circuitry Never ...

Page 5: ...modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed throug...

Page 6: ... appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Warning Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves Caution There is a risk of surface damage if you do...

Page 7: ...em thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Place the me...

Page 8: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only Warning Risk of injury The light emitted ...

Page 9: ...sionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Accessories not included in the scope of delivery Note These instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installatio...

Page 10: ...en Installation instructions 10 INSTALLATION INSTRUCTIONS Installation instructions Installationinstructions PLQ PLQ PLQ PLQ PLQ PLQ PLQ PLQ ...

Page 11: ...e being operated together the largest specified clearance applies Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There must be no flying sparks When conveying the exhaust air...

Page 12: ...stening components must be fixed firmly and securely Risk of injury The appliance is heavy To move the appliance 2 people are required Use only suitable tools and equipment Risk of injury Changes to the electrical or mechanical assembly are dangerous and may lead to malfunctions Do not make any changes to the electrical or mechanical assembly Warning Risk of electric shock Components inside the ap...

Page 13: ...power supply The appliance must only be connected to a protective contact socket that has been correctly installed If the plug can no longer be reached after installation an energy isolating device in the phases must be provided in the permanent electrical installation in accordance with the installation regulations The permanent electrical installation must only be wired by a professional electri...

Page 14: ...en Installation 14 Installation 1 Attaching and aligning the appliance 2 Mark the hole for the safety screw 3 Remove the appliance once more ª ...

Page 15: ...ns Use sealing strips for deviating pipe diameters Connecting the appliance to the power supply Connecting the air extractor Note If using an aluminium pipe smooth the connection area beforehand 1 Attach the air extractor pipe directly to the air pipe connector 2 Connect to air extractor opening 3 Seal the joints appropriately Connect the power supply 1 Plug the mains plug into the earthed socket ...

Page 16: ...me com Carl Wery Straße 34 81739 München GERMANY 9001283712 9001283712 970810 Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom ...